[ACTIVE]Samsung WaterWall / StormWash / Bespoke Linear Wash Dishwasher: Water level sensor mismatch E12; analog pressure transducer reading conflicts with circulation pump motor load telemetry.
On Samsung dishwashers utilizing WaterWall sweeping linear spray bar, StormWash rotating nozzle cluster, and auto-release door opening: Grease accumulation in sump air trap chamber, split pressure sensor tube, or drifting diaphragm sensor.
Flush air trap dome in sump using hot water syringe. Check pressure hose for splits. Measure pressure sensor output voltage (0.5V–4.0V DC). Press and hold the Start/Reset button for 3 seconds until '0:01' or 'CL' appears, wait for drain cycle completion, then cycle power off.