Skip to content
CodesErreur.comSWISS PRO ENGINE
Core Diagnostics
DiagnosticsBrandsOEM ManualsSpecialistsAI EngineerPRO
Workshop Tools
Diagnostic ToolsNEW
Hardware interfaces & test probes
Find Rating Plate
Locate exact E-Nr, PNC & serial codes
Parts Locator
Global OEM spare parts suppliers
Community & Career
Academy & Courses
Masterclasses by senior technicians
Certification ExamsPRO
Verify your B2B technical credentials
Elite Forum
Peer-to-peer field troubleshooting
Tech Jobs
B2B recruitment & field opportunities
Leaderboard
Global ranking of verified specialists
Certified Appliance Engineering EcosystemApply for Certification →
Language Selector
ENFRDEITESPT
ENEnglishFRFrançaisDEDeutschITItalianoESEspañolPTPortuguês
Account & Access
Upgrade PRO
Back to Search
OEM VERIFIED BENCH
OFFICIAL FAULT CODEF02
Samsung
Samsung // OFFICIAL DIAGNOSTIC BENCH

Samsung Dishwasher F02

DishwasherDrainage System & Drain Pump
Premium built-in dishwasher with open illuminated stainless steel interior and precision spray arms
Dishwasher
Select Appliance Type
0ms Instant Telemetry Switch
Other Brands Sharing Code F02:LGF02WhirlpoolF02BekoF02IndesitF02BauknechtF02V-ZugF02AristonF02BrandtF02De DietrichF02LiebherrF02

Symptom / Description

FAULT

Samsung WaterWall / StormWash / Bespoke Linear Wash Dishwasher: Water inlet triac short fault F02; water inlet solenoid valve is powered continuously even when machine is powered down.

TELEMETRY // LIVESIG: FAULT_DETECTED

Root Cause

ROOT CAUSE

On Samsung dishwashers featuring WaterWall sweeping linear spray bar, StormWash rotating nozzle cluster, and auto-release door opening: Electrical short-circuit through silicon gate of inlet triac on PCB, resulting from solenoid coil surge.

CIRCUIT // SUBSYSTEMLOGIC: ROOT_ISOLATED

Repair Instructions

UNLOCKED
1Shut off water tap immediately. Disconnect mains power. Inspect power board for scorched triac package. Replace failed triac or control board. Press and hold the Start/Reset button for 3 seconds until '0:01' or 'CL' appears, wait for drain cycle completion, then cycle power off.
AI diagnostic workshop engine analyzing appliance circuit schematics and error telemetry in real time
AI WORKSHOP PROTOCOL ENGINE
Direct extraction from OEM factory manuals & wiring schematics

Field Actions

DISPATCH
Need Help? Call a Certified TechnicianWorldwide Samsung Parts Finder
Electrical & Safety Protocol

Always disconnect appliance from 230V/400V mains before opening panels. Use CAT III multimeter for circuit testing.

SWISS ATELIER TECHNICAL BLUEPRINT // 2026 SCHEMATIC STANDARD

Hydraulic & Drainage Loop

Drain Pump M2, Impeller Chamber, Sump Filter & Analog Pressostat

CALIBRATED TEST POINTS (TP1 / TP2)
ACTIVE MULTIMETER BENCH
MAIN PCB CONTROLLER32-BIT MCUFIRMWARE v26.4SOLID-STATE RELAYTRIAC TY1 // 16A 600V230V AC MAINSLINE FILTER L-NJ1J2TP1TP2PRECISION BENCH METERAUTO-RANGE ΩCAT III168.4 ΩVΩCOMDRAIN PUMP M2DRAIN OUTFLOWRATED COIL: 150-280Ω
Target Component
Drain Pump Motor Stator Coils
Nominal Resistance / Test Range
160Ω–220Ω (Sync 230V) / 20Ω–45Ω (3-Phase BLDC)
Test Harness Pins
Across pump motor spade terminals (L-N unclipped)
Diagnostic Verification Rule
Measure coil resistance unplugged. If OL (open loop) or < 50 Ω (shorted), replace pump assembly.
CALIBRATED BENCH PROTOCOL // CAT III 600V

Workshop Verification & Safety Checklist

WORKSHOP VERIFICATION PROTOCOLDrainage System & Drain PumpDishwasher
2. Multimeter & Electrical Bench Tests (Ω)
MODE: OHMMETER (Ω)AUTO-RANGE
Precision digital multimeter probes measuring electrical resistance in Ohms on an appliance control board
CALIBRATED METROLOGY RESISTANCE BENCH (CAT III)
Nominal Resistance (Ω)
160Ω–220Ω (Sync 230V) / 20Ω–45Ω (3-Phase BLDC)NOMINAL
0 Ω (SHORT)CALIBRATED BAND∞ OL (OPEN)
▲ NOMINAL OPERATING WINDOW
Target Component:Drain Pump Motor Stator Coils
Test Pins & Connections
PROBE (+)
PROBE (-)
Across pump motor spade terminals (L-N unclipped)
Tolerance & Diagnostic Criteria±10% balance. Insulation resistance between coil and motor chassis must exceed 20MΩ.
1. Pre-Intervention Electrical Safety Protocols
  • !Electrical Safety Protocol: Isolate 230V mains power before accessing the lower pump housing.
  • !Prepare a shallow basin and absorption towels: expect 3 to 10 liters of stagnant trapped water upon filter opening.
  • !Beware of sharp foreign objects (broken glass, needles, screws) trapped inside the impeller cavity.
3. Preliminary Mechanical & Visual Checks
  • Unscrew coin trap filter and clear all foreign debris (coins, hairpins, bra underwires).
  • Rotate pump impeller manually: synchronous magnetic rotors should snap cleanly in 90° intervals without jamming.
  • Check drain hose for kinks, blockages, or unpunched sink spigots; verify drain height is between 65cm and 100cm.
Perform these diagnostic steps before triggering AI Deep Search or replacing boards.Certified Workshop Routine

Frequently Asked Questions: Samsung F02

FAQ TREE
What does error code F02 mean on a Samsung appliance?

Samsung error code F02 indicates: Samsung WaterWall / StormWash / Bespoke Linear Wash Dishwasher: Water inlet triac short fault F02; water inlet solenoid valve is powered continuously even when machine is powered down..

What is the root cause of Samsung error code F02?

The primary root cause for Samsung code F02 is: On Samsung dishwashers featuring WaterWall sweeping linear spray bar, StormWash rotating nozzle cluster, and auto-release door opening: Electrical short-circuit through silicon gate of inlet triac on PCB, resulting from solenoid coil surge..

How do I fix or resolve Samsung error code F02?

To resolve error code F02: Shut off water tap immediately. Disconnect mains power. Inspect power board for scorched triac package. Replace failed triac or control board. Press and hold the Start/Reset button for 3 seconds until '0:01' or 'CL' appears, wait for drain cycle completion, then cycle power off.

Is it safe to clear Samsung error code F02 by resetting power?

Resetting power (unplugging for 5–10 minutes) clears temporary memory errors. However, if Samsung code F02 persists, the physical component causing On Samsung dishwashers featuring WaterWall sweeping linear spray bar, StormWash rotating nozzle cluster, and auto-release door opening: Electrical short-circuit through silicon gate of inlet triac on PCB, resulting from solenoid coil surge. must be inspected or replaced.

How do I test electrical resistance for Samsung code F02 using a multimeter?

Set a digital multimeter to ohms (Ω). Disconnect power and test Drain Pump Motor Stator Coils across Across pump motor spade terminals (L-N unclipped). Expected nominal reading is 160Ω–220Ω (Sync 230V) / 20Ω–45Ω (3-Phase BLDC). Tolerance: ±10% balance. Insulation resistance between coil and motor chassis must exceed 20MΩ..

What safety protocol must be followed before servicing Samsung code F02?

Standard electrical safety protocol: 1. Disconnect 230V mains power before opening panels. 2. Verify zero voltage at test points. 3. Allow hot water or heating elements to cool below 30°C before handling.

What does Samsung error code F02 mean on a Dishwasher?

Samsung error code F02 on a Dishwasher indicates: Samsung WaterWall / StormWash / Bespoke Linear Wash Dishwasher: Water inlet triac short fault F02; water inlet solenoid valve is powered continuously even when machine is powered down.. Primary cause: On Samsung dishwashers featuring WaterWall sweeping linear spray bar, StormWash rotating nozzle cluster, and auto-release door opening: Electrical short-circuit through silicon gate of inlet triac on PCB, resulting from solenoid coil surge.. Recommended solution: Shut off water tap immediately. Disconnect mains power. Inspect power board for scorched triac package. Replace failed triac or control board. Press and hold the Start/Reset button for 3 seconds until '0:01' or 'CL' appears, wait for drain cycle completion, then cycle power off..

What does Samsung error code F02 mean on a Tumble Dryer?

Samsung error code F02 on a Tumble Dryer indicates: Samsung OptimalDry / Bespoke AI Heat Pump Tumble Dryer: Room ambient temperature outside operating boundary F02; appliance pauses operation to protect heat pump thermodynamic cycle.. Primary cause: On Samsung dryers with OptimalDry triple sensor system (temperature, humidity, condenser mesh), and digital inverter heat pump: Room ambient temperature below +5°C (risk of refrigerant freeze/oil thickening) or above +35°C (high pressure thermal trip).. Recommended solution: Ensure laundry room is heated above +10°C or adequately ventilated below +30°C. Check ambient NTC sensor located behind front control panel (~10 kΩ at 25°C). Power on, touch and hold Dry Level and Time Dry pads simultaneously for 7 seconds until the display chime triggers, then power off..

What does Samsung error code F02 mean on a Hob?

Samsung error code F02 on a Hob indicates: Samsung Virtual Flame / Chef Collection Flex Zone Induction Cooktop: Undersink installation cavity ambient overtemperature F02; cooktop pauses cooking and runs cooling fan at maximum speed.. Primary cause: On Samsung cooktops with Virtual Flame LED cooking glow simulation, Flex Zone wide inductors, and detachable magnetic control dial: Internal casing temperature exceeded +65°C due to blocked intake grille under countertop or oven underneath heating cabinet.. Recommended solution: Open cabinet drawers underneath cooktop to purge hot air. Ensure a 5 mm ventilation gap exists beneath front edge of countertop. Check casing NTC (~10 kΩ at 25°C). Remove all cookware and liquids from glass. Power down circuit breaker for 60 seconds, restore power and press Control Lock for 4 seconds..

What does Samsung error code F02 mean on a Oven?

Samsung error code F02 on a Oven indicates: Samsung Dual Cook Flex / Infinite Line / Bespoke Convection Oven: Continuous capacitive touch key trigger F02; front panel beeps persistently and ignores user touch commands.. Primary cause: On Samsung ovens with Dual Cook Flex articulated divider door, dual hot-air convection fans, and SmartThings culinary telemetry: Grease, condensation, or cleaner film accumulated on glass fascia over capacitive touch pads, or warped optical light guide.. Recommended solution: Clean and thoroughly dry glass fascia with isopropyl alcohol microfiber cloth. Inspect spring contacts between PCB and touch glass for uniform tension. Turn off selector dial, unplug oven power cord or switch off main fuse for 5 minutes, reconnect power and configure initial clock time..

What does Samsung error code F02 mean on a Refrigerator / Freezer?

Samsung error code F02 on a Refrigerator / Freezer indicates: Samsung Twin Cooling Plus / Family Hub / Bespoke French Door Refrigerator: Defrost water drain gutter iced up or heater fault F02; meltwater overflows into bottom freezer drawers and freezes into a solid sheet.. Primary cause: On Samsung refrigeration units with Twin Cooling Plus independent dual evaporators, Metal Cooling retention plate, and Digital Inverter compressor: Blocked drain funnel rubber duckbill valve at rear, open drain gutter heater trace wire (~800–1400 Ω), or algae/lint clogs.. Recommended solution: Flush drain funnel with hot water and flexible nylon probe. Clean duckbill valve behind compressor. Measure resistance of drain trace heater (~800–1400 Ω). Press and hold Power Freeze and Power Cool buttons simultaneously for 8 seconds until the display flashes and clears stored fault codes..

What does Samsung error code F02 mean on a Washing Machine?

Samsung error code F02 on a Washing Machine indicates: Samsung EcoBubble / AddWash / Bespoke AI Digital Inverter Washer: Inverter module thermal alarm F02; motor drive controller halts operation due to excessive heatsink temperature (>88°C).. Primary cause: On Samsung washing machines utilizing EcoBubble foam generator, Digital Inverter BLDC drive motor, and VRT Plus active vibration reduction: Heavy continuous boiling wash loads, degraded thermal paste between IPM and aluminum heatsink, or dust accumulation.. Recommended solution: Allow machine to cool for 45 minutes. Clean ventilation slots and heatsink fins on inverter board. Reapply non-conductive thermal grease to IPM bridge. Power on, press and hold Spin Speed and Temperature keys together for 7 seconds until display clears or sounds a melody, then restart cycle..

Community Verification

COMMUNITY

Did this solution resolve the issue?

Samsung F02 — Multi-Appliance Technical Reference

Verified OEM diagnostic specifications across all appliance systems sharing this fault code.

Samsung F02 — Dishwasher

[ACTIVE]
Symptom / Description:

Samsung WaterWall / StormWash / Bespoke Linear Wash Dishwasher: Water inlet triac short fault F02; water inlet solenoid valve is powered continuously even when machine is powered down.

Root Cause:

On Samsung dishwashers featuring WaterWall sweeping linear spray bar, StormWash rotating nozzle cluster, and auto-release door opening: Electrical short-circuit through silicon gate of inlet triac on PCB, resulting from solenoid coil surge.

Repair Instructions:

Shut off water tap immediately. Disconnect mains power. Inspect power board for scorched triac package. Replace failed triac or control board. Press and hold the Start/Reset button for 3 seconds until '0:01' or 'CL' appears, wait for drain cycle completion, then cycle power off.

Samsung F02 — Dryer

Symptom / Description:

Samsung OptimalDry / Bespoke AI Heat Pump Tumble Dryer: Room ambient temperature outside operating boundary F02; appliance pauses operation to protect heat pump thermodynamic cycle.

Root Cause:

On Samsung dryers with OptimalDry triple sensor system (temperature, humidity, condenser mesh), and digital inverter heat pump: Room ambient temperature below +5°C (risk of refrigerant freeze/oil thickening) or above +35°C (high pressure thermal trip).

Repair Instructions:

Ensure laundry room is heated above +10°C or adequately ventilated below +30°C. Check ambient NTC sensor located behind front control panel (~10 kΩ at 25°C). Power on, touch and hold Dry Level and Time Dry pads simultaneously for 7 seconds until the display chime triggers, then power off.

Samsung F02 — Hob

Symptom / Description:

Samsung Virtual Flame / Chef Collection Flex Zone Induction Cooktop: Undersink installation cavity ambient overtemperature F02; cooktop pauses cooking and runs cooling fan at maximum speed.

Root Cause:

On Samsung cooktops with Virtual Flame LED cooking glow simulation, Flex Zone wide inductors, and detachable magnetic control dial: Internal casing temperature exceeded +65°C due to blocked intake grille under countertop or oven underneath heating cabinet.

Repair Instructions:

Open cabinet drawers underneath cooktop to purge hot air. Ensure a 5 mm ventilation gap exists beneath front edge of countertop. Check casing NTC (~10 kΩ at 25°C). Remove all cookware and liquids from glass. Power down circuit breaker for 60 seconds, restore power and press Control Lock for 4 seconds.

Samsung F02 — Oven

Symptom / Description:

Samsung Dual Cook Flex / Infinite Line / Bespoke Convection Oven: Continuous capacitive touch key trigger F02; front panel beeps persistently and ignores user touch commands.

Root Cause:

On Samsung ovens with Dual Cook Flex articulated divider door, dual hot-air convection fans, and SmartThings culinary telemetry: Grease, condensation, or cleaner film accumulated on glass fascia over capacitive touch pads, or warped optical light guide.

Repair Instructions:

Clean and thoroughly dry glass fascia with isopropyl alcohol microfiber cloth. Inspect spring contacts between PCB and touch glass for uniform tension. Turn off selector dial, unplug oven power cord or switch off main fuse for 5 minutes, reconnect power and configure initial clock time.

Samsung F02 — Refrigerator / Freezer

Symptom / Description:

Samsung Twin Cooling Plus / Family Hub / Bespoke French Door Refrigerator: Defrost water drain gutter iced up or heater fault F02; meltwater overflows into bottom freezer drawers and freezes into a solid sheet.

Root Cause:

On Samsung refrigeration units with Twin Cooling Plus independent dual evaporators, Metal Cooling retention plate, and Digital Inverter compressor: Blocked drain funnel rubber duckbill valve at rear, open drain gutter heater trace wire (~800–1400 Ω), or algae/lint clogs.

Repair Instructions:

Flush drain funnel with hot water and flexible nylon probe. Clean duckbill valve behind compressor. Measure resistance of drain trace heater (~800–1400 Ω). Press and hold Power Freeze and Power Cool buttons simultaneously for 8 seconds until the display flashes and clears stored fault codes.

Samsung F02 — Washing Machine

Symptom / Description:

Samsung EcoBubble / AddWash / Bespoke AI Digital Inverter Washer: Inverter module thermal alarm F02; motor drive controller halts operation due to excessive heatsink temperature (>88°C).

Root Cause:

On Samsung washing machines utilizing EcoBubble foam generator, Digital Inverter BLDC drive motor, and VRT Plus active vibration reduction: Heavy continuous boiling wash loads, degraded thermal paste between IPM and aluminum heatsink, or dust accumulation.

Repair Instructions:

Allow machine to cool for 45 minutes. Clean ventilation slots and heatsink fins on inverter board. Reapply non-conductive thermal grease to IPM bridge. Power on, press and hold Spin Speed and Temperature keys together for 7 seconds until display clears or sounds a melody, then restart cycle.

SEMANTIC KNOWLEDGE GRAPH // SAMSUNG

Related Samsung Dishwasher Error Codes

Diagnostic Link Mesh14 OEM Cross-References

Cross-referenced diagnostic codes for technicians inspecting similar component subsystems.

F03Dishwasher
Water Level Pressure Switch & Air Dome
Samsung WaterWall / StormWash / Bespoke Linear Wash Dishwasher: Foam aeration cavitation fau...
Inspect Protocol
F04Dishwasher
Drainage System & Drain Pump
Samsung WaterWall / StormWash / Bespoke Linear Wash Dishwasher: Door latch status conflict F...
Inspect Protocol
F05Dishwasher
Water Level Pressure Switch & Air Dome
Samsung WaterWall / StormWash / Bespoke Linear Wash Dishwasher: Thermal safety cutout trippe...
Inspect Protocol
PEDishwasher
Drive Motor, Inverter & Tachometer Sensor
Half load function error.. Diagnostic error code PE reported on Samsung Dishwasher.
Inspect Protocol
7EDishwasher
General System & Mechanical Integration
On Samsung Dishwasher: WaterWall reflector error (on WaterWall models).
Inspect Protocol
9EDishwasher
Water Level Pressure Switch & Air Dome
Samsung 9E: Water level pressure sensor/switch frequency anomaly detected in Dishwasher.
Inspect Protocol
bE2Dishwasher
General System & Mechanical Integration
Samsung BE2: Operational cycle fault detected during Dishwasher program execution.
Inspect Protocol
E01Dishwasher
Water Level Pressure Switch & Air Dome
Samsung WaterWall / StormWash / Bespoke Linear Wash Dishwasher: Water fill timeout E01; sump...
Inspect Protocol
E02Dishwasher
Drainage System & Drain Pump
Samsung WaterWall / StormWash / Bespoke Linear Wash Dishwasher: Waste water draining fault E...
Inspect Protocol
E03Dishwasher
NTC Temperature Sensor & Thermistor
Samsung WaterWall / StormWash / Bespoke Linear Wash Dishwasher: Water heating failure E03; w...
Inspect Protocol
E04Dishwasher
Drainage System & Drain Pump
Samsung WaterWall / StormWash / Bespoke Linear Wash Dishwasher: Base pan leak detection E04;...
Inspect Protocol
E05Dishwasher
NTC Temperature Sensor & Thermistor
Samsung WaterWall / StormWash / Bespoke Linear Wash Dishwasher: Temperature sensor communica...
Inspect Protocol
E06Dishwasher
Drainage System & Drain Pump
Samsung WaterWall / StormWash / Bespoke Linear Wash Dishwasher: Circulation pump motor stall...
Inspect Protocol
E07Dishwasher
Drainage System & Drain Pump
Samsung WaterWall / StormWash / Bespoke Linear Wash Dishwasher: Spray diverter positioning e...
Inspect Protocol
CodesErreur.com

Premium appliance diagnostics & repair database.
Powered by AI to help certified technicians worldwide.

Trusted by professionals in CH & FR

Platform

Search DatabasePRO Diagnostic AIPRODiagnostic ToolsBrands

Workshop Tools

Brands (87)OEM ManualsFind Rating PlateParts Locator

For Technicians

SpecialistsTechnician ForumTech JobsPremium

Corporate

Terms of ServicePrivacy PolicyOfficial Swiss Repair Partner: Electroassistance
OPERATIONAL SAFETY SPECIFICATION

SAFETY DISCLAIMER

The technical information, diagnostic guides, error codes, and AI-generated suggestions provided on this website are intended exclusively for certified and qualified professionals. Appliance repair involves severe electrical hazards, high voltages, and mechanical risks that can result in fatal injury or severe property damage. If you are not a trained technician, do not attempt to repair any appliances. CodesErreur assumes no responsibility or liability for any damage, injury, or consequential losses resulting from the use of the information provided on this platform. You use all information entirely at your own risk.

© 2026 CodesErreur. All rights reserved.