Skip to content
CodesErreur.comSWISS PRO ENGINE
Core Diagnostics
DiagnosticsBrandsOEM ManualsSpecialistsAI EngineerPRO
Workshop Tools
Diagnostic ToolsNEW
Hardware interfaces & test probes
Find Rating Plate
Locate exact E-Nr, PNC & serial codes
Parts Locator
Global OEM spare parts suppliers
Community & Career
Academy & Courses
Masterclasses by senior technicians
Certification ExamsPRO
Verify your B2B technical credentials
Elite Forum
Peer-to-peer field troubleshooting
Tech Jobs
B2B recruitment & field opportunities
Leaderboard
Global ranking of verified specialists
Certified Appliance Engineering EcosystemApply for Certification →
Language Selector
ENFRDEITESPT
ENEnglishFRFrançaisDEDeutschITItalianoESEspañolPTPortuguês
Account & Access
Upgrade PRO
Back to Search
OEM VERIFIED BENCH
OFFICIAL FAULT CODEF02
Scholtès
Scholtès // OFFICIAL DIAGNOSTIC BENCH

Scholtès Hob F02

HobElectronic Control Board (PCB) & Bus Communications
Integrated luxury convection oven and induction cooktop with illuminated touch controls
Hob
Select Appliance Type
0ms Instant Telemetry Switch
Whirlpool / Indesit Group: Equivalent Code Across OEM Group Brands
Whirlpool / Indesit Global Electronic Architecture
WhirlpoolF02IndesitF02AristonF02HotpointF02BauknechtF02IgnisF02
Other Brands Sharing Code F02:SamsungF02LGF02BekoF02V-ZugF02BrandtF02De DietrichF02

Symptom / Description

FAULT

Scholtès Induction Touch Control & S-Line Direct Slider Cooktop: Diagnostic fault code F02 registered by the microcomputer controller. Induction generator left front zone IGBT driver fault

TELEMETRY // LIVESIG: FAULT_DETECTED

Root Cause

ROOT CAUSE

On Scholtès appliances engineered with Arcadia / E.G.O. high-frequency induction power modules with digital temperature monitoring across each inductor core, touch slider filtering, and dynamic phase balancing: IGBT power module shorted Metrological tolerance verification: diode test on IGBT 0.45V forward, OL reverse..

CIRCUIT // SUBSYSTEMLOGIC: ROOT_ISOLATED

Repair Instructions

UNLOCKED
1Disconnect mains power before servicing. Unplug the harness at the main PCB and use a calibrated digital multimeter: test left front IGBT transistors for short circuits. Inspect contacts for pin oxidation or loose terminals. Replace defective part if out of tolerance, re-energize and clear error: Ensure all cookware is removed and glass is completely dry. Turn off mains isolator switch for 90 seconds. Restore power and press the On/Off sensor firmly for 4 seconds until the hob performs self-calibration and beeps.
AI diagnostic workshop engine analyzing appliance circuit schematics and error telemetry in real time
AI WORKSHOP PROTOCOL ENGINE
Direct extraction from OEM factory manuals & wiring schematics

Field Actions

DISPATCH
Need Help? Call a Certified TechnicianWorldwide Scholtès Parts Finder
Electrical & Safety Protocol

Always disconnect appliance from 230V/400V mains before opening panels. Use CAT III multimeter for circuit testing.

SWISS ATELIER TECHNICAL BLUEPRINT // 2026 SCHEMATIC STANDARD

Main Control PCB, Refrigeration & Sensor Bus Loop

230V AC Mains Filter, Low-Voltage SMPS DC Rails & MCU I2C/UART Bus

CALIBRATED TEST POINTS (TP1 / TP2)
ACTIVE MULTIMETER BENCH
MAIN PCB CONTROLLER32-BIT MCUFIRMWARE v26.4SOLID-STATE RELAYTRIAC TY1 // 16A 600V230V AC MAINSLINE FILTER L-NJ1J2TP1TP2PRECISION BENCH METERAUTO-RANGE ΩCAT III12.05 V DCVΩCOMMAIN CONTROL BOARDSMPS TRANSFORMERPRIMARY 230V / SECONDARY DC+12V DC+5V DCI2C / UART SENSOR BUS
Target Component
PCB Power Supply Rails & DC Bus Filter Capacitors
Nominal Resistance / Test Range
Low-voltage rails: +5.0V DC (Logic), +12.0V DC (Relays), +3.3V DC (MCU). Relay coils: 200Ω–450Ω.
Test Harness Pins
Across SMPS output electrolytic capacitors on low-voltage side (test bench verification)
Diagnostic Verification Rule
Verify clean DC rails without ripple. Defective SMPS capacitors or burned MCU comm bus triggers system lock.
CALIBRATED BENCH PROTOCOL // CAT III 600V

Workshop Verification & Safety Checklist

WORKSHOP VERIFICATION PROTOCOLElectronic Control Board (PCB) & Bus CommunicationsHob / Cooktop
2. Multimeter & Electrical Bench Tests (Ω)
MODE: OHMMETER (Ω)AUTO-RANGE
Precision digital multimeter probes measuring electrical resistance in Ohms on an appliance control board
CALIBRATED METROLOGY RESISTANCE BENCH (CAT III)
Nominal Resistance (Ω)
Low-voltage rails: +5.0V DC (Logic), +12.0V DC (Relays), +3.3V DC (MCU). Relay coils: 200Ω–450Ω.NOMINAL
0 Ω (SHORT)CALIBRATED BAND∞ OL (OPEN)
▲ NOMINAL OPERATING WINDOW
Target Component:PCB Power Supply Rails & DC Bus Filter Capacitors
Test Pins & Connections
PROBE (+)
PROBE (-)
Across SMPS output electrolytic capacitors on low-voltage side (test bench verification)
Tolerance & Diagnostic CriteriaDC rail ripple must remain <50mV. Direct continuity (0Ω) across DC bus rails indicates dead short.
1. Pre-Intervention Electrical Safety Protocols
  • !High-Voltage Safety Protocol: Disconnect 230V power before unplugging edge connectors or removing PCB.
  • !High Voltage DC Warning: Wait at least 5 minutes for SMPS and inverter filter capacitors (up to 380V DC) to discharge safely.
  • !Electrostatic Discharge (ESD): Ground yourself to the metal chassis or wear an antistatic wrist strap before touching circuit tracks.
3. Preliminary Mechanical & Visual Checks
  • Inspect PCB tracks with a magnifying glass for blown triacs, darkened copper tracks, or cold solder joints on power relays.
  • Check electrolytic capacitors for bulging tops or leaked electrolyte residue around pins.
  • Verify edge connector locking clips are intact and pins are free of vibration fretting corrosion.
Perform these diagnostic steps before triggering AI Deep Search or replacing boards.Certified Workshop Routine

Frequently Asked Questions: Scholtès F02

FAQ TREE
What does error code F02 mean on a Scholtès appliance?

Scholtès error code F02 indicates: Scholtès Induction Touch Control & S-Line Direct Slider Cooktop: Diagnostic fault code F02 registered by the microcomputer controller. Induction generator left front zone IGBT driver fault.

What is the root cause of Scholtès error code F02?

The primary root cause for Scholtès code F02 is: On Scholtès appliances engineered with Arcadia / E.G.O. high-frequency induction power modules with digital temperature monitoring across each inductor core, touch slider filtering, and dynamic phase balancing: IGBT power module shorted Metrological tolerance verification: diode test on IGBT 0.45V forward, OL reverse...

How do I fix or resolve Scholtès error code F02?

To resolve error code F02: Disconnect mains power before servicing. Unplug the harness at the main PCB and use a calibrated digital multimeter: test left front IGBT transistors for short circuits. Inspect contacts for pin oxidation or loose terminals. Replace defective part if out of tolerance, re-energize and clear error: Ensure all cookware is removed and glass is completely dry. Turn off mains isolator switch for 90 seconds. Restore power and press the On/Off sensor firmly for 4 seconds until the hob performs self-calibration and beeps.

Is it safe to clear Scholtès error code F02 by resetting power?

Resetting power (unplugging for 5–10 minutes) clears temporary memory errors. However, if Scholtès code F02 persists, the physical component causing On Scholtès appliances engineered with Arcadia / E.G.O. high-frequency induction power modules with digital temperature monitoring across each inductor core, touch slider filtering, and dynamic phase balancing: IGBT power module shorted Metrological tolerance verification: diode test on IGBT 0.45V forward, OL reverse.. must be inspected or replaced.

How do I test electrical resistance for Scholtès code F02 using a multimeter?

Set a digital multimeter to ohms (Ω). Disconnect power and test PCB Power Supply Rails & DC Bus Filter Capacitors across Across SMPS output electrolytic capacitors on low-voltage side (test bench verification). Expected nominal reading is Low-voltage rails: +5.0V DC (Logic), +12.0V DC (Relays), +3.3V DC (MCU). Relay coils: 200Ω–450Ω.. Tolerance: DC rail ripple must remain <50mV. Direct continuity (0Ω) across DC bus rails indicates dead short..

What safety protocol must be followed before servicing Scholtès code F02?

Standard electrical safety protocol: 1. Disconnect 230V mains power before opening panels. 2. Verify zero voltage at test points. 3. Allow hot water or heating elements to cool below 30°C before handling.

What does Scholtès error code F02 mean on a Hob?

Scholtès error code F02 on a Hob indicates: Scholtès Induction Touch Control & S-Line Direct Slider Cooktop: Diagnostic fault code F02 registered by the microcomputer controller. Induction generator left front zone IGBT driver fault. Primary cause: On Scholtès appliances engineered with Arcadia / E.G.O. high-frequency induction power modules with digital temperature monitoring across each inductor core, touch slider filtering, and dynamic phase balancing: IGBT power module shorted Metrological tolerance verification: diode test on IGBT 0.45V forward, OL reverse... Recommended solution: Disconnect mains power before servicing. Unplug the harness at the main PCB and use a calibrated digital multimeter: test left front IGBT transistors for short circuits. Inspect contacts for pin oxidation or loose terminals. Replace defective part if out of tolerance, re-energize and clear error: Ensure all cookware is removed and glass is completely dry. Turn off mains isolator switch for 90 seconds. Restore power and press the On/Off sensor firmly for 4 seconds until the hob performs self-calibration and beeps..

What does Scholtès error code F02 mean on a Oven?

Scholtès error code F02 on a Oven indicates: Scholtès Galileo / Multi-Oven / S-Line Pyrolytic Built-in Oven: Diagnostic fault code F02 registered by the microcomputer controller. Temperature sensor probe PT500/PT1000 open circuit (>1200 Ω at 20°C). Primary cause: On Scholtès appliances engineered with Galileo electronic architecture with high-density pyrolytic thermal barrier, PT500 probe feedback, Hall-effect cooling fan regulation, and bi-metallic motorized door latch: cavity RTD sensor disconnected or wire severed Metrological tolerance verification: nominal 540 Ω (PT500) or 1080 Ω (PT1000) at 20°C... Recommended solution: Disconnect mains power before servicing. Unplug the harness at the main PCB and use a calibrated digital multimeter: measure sensor resistance across probe pins on main relay board. Inspect contacts for pin oxidation or loose terminals. Replace defective part if out of tolerance, re-energize and clear error: Turn temperature and function dials to 0. Switch off oven circuit breaker for 60 seconds. Restore power, touch and hold the Timer/Clock button for 4 seconds until '0:00' flashes and error code extinguishes..

What does Scholtès error code F02 mean on a Washing Machine?

Scholtès error code F02 on a Washing Machine indicates: Scholtès MLXE / SLW Supreme Care Integrated Washer-Dryer: Diagnostic fault code F02 registered by the microcomputer controller. Motor tachometer generator open / no pulses received. Primary cause: On Scholtès appliances engineered with Arcadia 2 heavy-duty inverter drive with digital inductive pressure sensor, dynamic drum unbalance detection, and ceramic-coated heating element: tachometer coil open or loose magnet on motor shaft Metrological tolerance verification: tacho coil resistance 115 Ω to 180 Ω... Recommended solution: Disconnect mains power before servicing. Unplug the harness at the main PCB and use a calibrated digital multimeter: measure tacho coil resistance and test AC output voltage while spinning drum. Inspect contacts for pin oxidation or loose terminals. Replace defective part if out of tolerance, re-energize and clear error: Turn selector knob to Reset/Cancel (or Off). Press and hold the Start/Pause button for 6 seconds until the drain pump runs momentarily and door lock clicks open, indicating clearing of fault code..

What does Scholtès error code F02 mean on a Refrigerator / Freezer?

Scholtès error code F02 on a Refrigerator / Freezer indicates: Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code F02 indicates freezer evaporator NTC sensor out of calibration or short-circuit detected.. Primary cause: On Scholtès refrigerators (Scholtès Haute Horlogerie Culinaire sensors and micro-electronic platform architecture): Internal short in NTC bead, water freeze expansion crushing capsule, or pinched harness (2.7 kΩ at 25°C, 23.3 kΩ at -18°C).. Recommended solution: Disconnect power. Unclip sensor from freezer evaporator tubing. Measure resistance: if reading is < 500 Ω at sub-zero temperatures, replace NTC sensor assembly. Press and hold Alarm Reset pad for 5 seconds, verify compartment display stops blinking, and allow 12h for complete stabilization..

What does Scholtès error code F02 mean on a Tumble Dryer?

Scholtès error code F02 on a Tumble Dryer indicates: Scholtès Heat Pump Sensor Dry Tumble Dryer: Drum drive motor stalled or thermal protector tripped F02; motor winding overheats and internal bimetallic klixon opens.. Primary cause: On Scholtès tumble dryers: Seized drum support rollers, broken idler pulley bearing, defective motor run capacitor (10–16 µF), or jammed blower fan wheel.. Recommended solution: Rotate drum by hand to check for mechanical binding. Test motor run capacitor with capacitance meter (10–16 µF). Check motor winding resistance (20–35 Ω). Switch selector to Stop, press and hold Start/Pause for 5 seconds to clear error memory, then power off for 1 minute..

Community Verification

COMMUNITY

Did this solution resolve the issue?

Scholtès F02 — Multi-Appliance Technical Reference

Verified OEM diagnostic specifications across all appliance systems sharing this fault code.

Scholtès F02 — Hob

[ACTIVE]
Symptom / Description:

Scholtès Induction Touch Control & S-Line Direct Slider Cooktop: Diagnostic fault code F02 registered by the microcomputer controller. Induction generator left front zone IGBT driver fault

Root Cause:

On Scholtès appliances engineered with Arcadia / E.G.O. high-frequency induction power modules with digital temperature monitoring across each inductor core, touch slider filtering, and dynamic phase balancing: IGBT power module shorted Metrological tolerance verification: diode test on IGBT 0.45V forward, OL reverse..

Repair Instructions:

Disconnect mains power before servicing. Unplug the harness at the main PCB and use a calibrated digital multimeter: test left front IGBT transistors for short circuits. Inspect contacts for pin oxidation or loose terminals. Replace defective part if out of tolerance, re-energize and clear error: Ensure all cookware is removed and glass is completely dry. Turn off mains isolator switch for 90 seconds. Restore power and press the On/Off sensor firmly for 4 seconds until the hob performs self-calibration and beeps.

Scholtès F02 — Oven

Symptom / Description:

Scholtès Galileo / Multi-Oven / S-Line Pyrolytic Built-in Oven: Diagnostic fault code F02 registered by the microcomputer controller. Temperature sensor probe PT500/PT1000 open circuit (>1200 Ω at 20°C)

Root Cause:

On Scholtès appliances engineered with Galileo electronic architecture with high-density pyrolytic thermal barrier, PT500 probe feedback, Hall-effect cooling fan regulation, and bi-metallic motorized door latch: cavity RTD sensor disconnected or wire severed Metrological tolerance verification: nominal 540 Ω (PT500) or 1080 Ω (PT1000) at 20°C..

Repair Instructions:

Disconnect mains power before servicing. Unplug the harness at the main PCB and use a calibrated digital multimeter: measure sensor resistance across probe pins on main relay board. Inspect contacts for pin oxidation or loose terminals. Replace defective part if out of tolerance, re-energize and clear error: Turn temperature and function dials to 0. Switch off oven circuit breaker for 60 seconds. Restore power, touch and hold the Timer/Clock button for 4 seconds until '0:00' flashes and error code extinguishes.

Scholtès F02 — Washing Machine

Symptom / Description:

Scholtès MLXE / SLW Supreme Care Integrated Washer-Dryer: Diagnostic fault code F02 registered by the microcomputer controller. Motor tachometer generator open / no pulses received

Root Cause:

On Scholtès appliances engineered with Arcadia 2 heavy-duty inverter drive with digital inductive pressure sensor, dynamic drum unbalance detection, and ceramic-coated heating element: tachometer coil open or loose magnet on motor shaft Metrological tolerance verification: tacho coil resistance 115 Ω to 180 Ω..

Repair Instructions:

Disconnect mains power before servicing. Unplug the harness at the main PCB and use a calibrated digital multimeter: measure tacho coil resistance and test AC output voltage while spinning drum. Inspect contacts for pin oxidation or loose terminals. Replace defective part if out of tolerance, re-energize and clear error: Turn selector knob to Reset/Cancel (or Off). Press and hold the Start/Pause button for 6 seconds until the drain pump runs momentarily and door lock clicks open, indicating clearing of fault code.

Scholtès F02 — Refrigerator / Freezer

Symptom / Description:

Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code F02 indicates freezer evaporator NTC sensor out of calibration or short-circuit detected.

Root Cause:

On Scholtès refrigerators (Scholtès Haute Horlogerie Culinaire sensors and micro-electronic platform architecture): Internal short in NTC bead, water freeze expansion crushing capsule, or pinched harness (2.7 kΩ at 25°C, 23.3 kΩ at -18°C).

Repair Instructions:

Disconnect power. Unclip sensor from freezer evaporator tubing. Measure resistance: if reading is < 500 Ω at sub-zero temperatures, replace NTC sensor assembly. Press and hold Alarm Reset pad for 5 seconds, verify compartment display stops blinking, and allow 12h for complete stabilization.

Scholtès F02 — Dryer

Symptom / Description:

Scholtès Heat Pump Sensor Dry Tumble Dryer: Drum drive motor stalled or thermal protector tripped F02; motor winding overheats and internal bimetallic klixon opens.

Root Cause:

On Scholtès tumble dryers: Seized drum support rollers, broken idler pulley bearing, defective motor run capacitor (10–16 µF), or jammed blower fan wheel.

Repair Instructions:

Rotate drum by hand to check for mechanical binding. Test motor run capacitor with capacitance meter (10–16 µF). Check motor winding resistance (20–35 Ω). Switch selector to Stop, press and hold Start/Pause for 5 seconds to clear error memory, then power off for 1 minute.

SEMANTIC KNOWLEDGE GRAPH // SCHOLTÈS

Related Scholtès Hob / Cooktop Error Codes

Diagnostic Link Mesh14 OEM Cross-References

Cross-referenced diagnostic codes for technicians inspecting similar component subsystems.

F03Hob
Electronic Control Board (PCB) & Bus Communications
Scholtès Induction Touch Control & S-Line Direct Slider Cooktop: Diagnostic fault code F03 r...
Inspect Protocol
F04Hob
Electronic Control Board (PCB) & Bus Communications
Scholtès Induction Touch Control & S-Line Direct Slider Cooktop: Diagnostic fault code F04 r...
Inspect Protocol
F05Hob
NTC Temperature Sensor & Thermistor
Scholtès Induction Touch Control & S-Line Direct Slider Cooktop: Diagnostic fault code F05 r...
Inspect Protocol
F06Hob
NTC Temperature Sensor & Thermistor
Scholtès Induction Touch Control & S-Line Direct Slider Cooktop: Diagnostic fault code F06 r...
Inspect Protocol
F07Hob
Electronic Control Board (PCB) & Bus Communications
Scholtès Induction Touch Control & S-Line Direct Slider Cooktop: Diagnostic fault code F07 r...
Inspect Protocol
F08Hob
Electronic Control Board (PCB) & Bus Communications
Scholtès Induction Touch Control & S-Line Direct Slider Cooktop: Diagnostic fault code F08 r...
Inspect Protocol
F12Hob
NTC Temperature Sensor & Thermistor
Scholtès Induction Touch Control & S-Line Direct Slider Cooktop: Diagnostic fault code F12 r...
Inspect Protocol
F47Hob
Electronic Control Board (PCB) & Bus Communications
Scholtès Induction Touch Control & S-Line Direct Slider Cooktop: Diagnostic fault code F47 r...
Inspect Protocol
F48Hob
Heating Element, Thermostat & Safety Fuse
Scholtès Induction Touch Control & S-Line Direct Slider Cooktop: Diagnostic fault code F48 r...
Inspect Protocol
F49Hob
Heating Element, Thermostat & Safety Fuse
Scholtès Induction Touch Control & S-Line Direct Slider Cooktop: Diagnostic fault code F49 r...
Inspect Protocol
LHob
NTC Temperature Sensor & Thermistor
Scholtès Induction Touch Control & S-Line Direct Slider Cooktop: Diagnostic fault code L reg...
Inspect Protocol
U400Hob
Electronic Control Board (PCB) & Bus Communications
Scholtès Induction Touch Control & S-Line Direct Slider Cooktop: Diagnostic fault code U400 ...
Inspect Protocol
E1Hob
NTC Temperature Sensor & Thermistor
Scholtès Induction Touch Control & S-Line Direct Slider Cooktop: Diagnostic fault code E1 re...
Inspect Protocol
E2Hob
NTC Temperature Sensor & Thermistor
Scholtès Induction Touch Control & S-Line Direct Slider Cooktop: Diagnostic fault code E2 re...
Inspect Protocol
CodesErreur.com

Premium appliance diagnostics & repair database.
Powered by AI to help certified technicians worldwide.

Trusted by professionals in CH & FR

Platform

Search DatabasePRO Diagnostic AIPRODiagnostic ToolsBrands

Workshop Tools

Brands (87)OEM ManualsFind Rating PlateParts Locator

For Technicians

SpecialistsTechnician ForumTech JobsPremium

Corporate

Terms of ServicePrivacy PolicyOfficial Swiss Repair Partner: Electroassistance
OPERATIONAL SAFETY SPECIFICATION

SAFETY DISCLAIMER

The technical information, diagnostic guides, error codes, and AI-generated suggestions provided on this website are intended exclusively for certified and qualified professionals. Appliance repair involves severe electrical hazards, high voltages, and mechanical risks that can result in fatal injury or severe property damage. If you are not a trained technician, do not attempt to repair any appliances. CodesErreur assumes no responsibility or liability for any damage, injury, or consequential losses resulting from the use of the information provided on this platform. You use all information entirely at your own risk.

© 2026 CodesErreur. All rights reserved.

Terms of Service Privacy Policy