Scholtès F05 — Hob
[ACTIVE]Scholtès Induction Touch Control & S-Line Direct Slider Cooktop: Diagnostic fault code F05 registered by the microcomputer controller. Induction coil NTC thermistor disconnected or open circuit
On Scholtès appliances engineered with Arcadia / E.G.O. high-frequency induction power modules with digital temperature monitoring across each inductor core, touch slider filtering, and dynamic phase balancing: thermistor wire severed Metrological tolerance verification: nominal 100.0 kΩ at 25°C..
Disconnect mains power before servicing. Unplug the harness at the main PCB and use a calibrated digital multimeter: measure coil sensor resistance on power board connector. Inspect contacts for pin oxidation or loose terminals. Replace defective part if out of tolerance, re-energize and clear error: Ensure all cookware is removed and glass is completely dry. Turn off mains isolator switch for 90 seconds. Restore power and press the On/Off sensor firmly for 4 seconds until the hob performs self-calibration and beeps.