Field Actions
DISPATCHAlways disconnect appliance from 230V/400V mains before opening panels. Use CAT III multimeter for circuit testing.
Frequently Asked Questions: Sekom E16
FAQ TREEWhat does error code E16 mean on a Sekom appliance?
Sekom error code E16 indicates: Euronics Sekom SW Series Electronic Front-Loading Washing Machine Line: Diagnostic fault code E16 registered by the microcomputer controller. Excessive foam or detergent overdosing detected during spin drain sequence.
What is the root cause of Sekom error code E16?
The primary root cause for Sekom code E16 is: On Euronics Sekom Italian private label appliances engineered with OEM electronics engineered with Italian retail wash chassis with 2000W heating element (25-28 Ω), 12 kΩ NTC sensor, and drain pump (165-210 Ω): non-HE detergent used, drain pump aerating foam mixture, or pressure chamber trapped with lather. Metrological tolerance verification: pressure sensor reads > 40 mm H2O while empty drain pump runs at nominal 230 VAC 50 Hz..
How do I fix or resolve Sekom error code E16?
To resolve error code E16: Disconnect mains power before servicing. Unplug the harness at the main PCB and use a calibrated digital multimeter: allow machine to complete auto foam dissipation dwell, run empty 60°C rinse cycle without detergent, clean trap. Inspect contacts for pin oxidation or loose terminals. Replace defective part if out of tolerance, re-energize and clear error: rotate the program knob to Off, hold the Start/Pause key for 5 seconds until the door interlock releases and cycle status resets.
Is it safe to clear Sekom error code E16 by resetting power?
Resetting power (unplugging for 5–10 minutes) clears temporary memory errors. However, if Sekom code E16 persists, the physical component causing On Euronics Sekom Italian private label appliances engineered with OEM electronics engineered with Italian retail wash chassis with 2000W heating element (25-28 Ω), 12 kΩ NTC sensor, and drain pump (165-210 Ω): non-HE detergent used, drain pump aerating foam mixture, or pressure chamber trapped with lather. Metrological tolerance verification: pressure sensor reads > 40 mm H2O while empty drain pump runs at nominal 230 VAC 50 Hz. must be inspected or replaced.
How do I test electrical resistance for Sekom code E16 using a multimeter?
Set a digital multimeter to ohms (Ω). Disconnect power and test NTC Temperature Sensor Probe (Thermistor) across Across sensor pins 1-2 (unplugged harness). Expected nominal reading is 4.8kΩ–12kΩ (at 20°C–25°C). Tolerance: Negative temperature coefficient: resistance drops smoothly when warmed with fingers. OL = open circuit..
What safety protocol must be followed before servicing Sekom code E16?
Standard electrical safety protocol: 1. Disconnect 230V mains power before opening panels. 2. Verify zero voltage at test points. 3. Allow hot water or heating elements to cool below 30°C before handling.
Community Verification
COMMUNITYDid this solution resolve the issue?



