Siemens E06 — Dishwasher
[ACTIVE]Siemens iQ300 / iQ500 / iQ700 / iQ800 studioLine Zeolith & varioSpeed Plus: Door Hall sensor latch anomaly E06; control unit detects open door signal or invalid magnetic reed feedback during cycle.
On Siemens dishwashers: Misaligned door catch magnet, defective Hall sensor PCB in door frame, damaged wire harness in bottom hinge, or door latch worn.
Verify door catch magnet is securely fitted in door trim. Measure 5V DC supply to Hall sensor. Check continuity of signal wire to main PCB. Press and hold Start button for 4 seconds until display indicates '0:01', wait for evacuation pump, then power off.