Siemens E11 — Dishwasher
[ACTIVE]Siemens iQ300 / iQ500 / iQ700 / iQ800 studioLine Zeolith & varioSpeed Plus: NTC temperature sensor fault E11; thermistor resistance signal open, shorted, or outside calibration limits.
On Siemens dishwashers: Defective NTC thermistor in heat pump or sump, corroded connector terminals, or broken signal lead in lower harness.
Measure NTC sensor resistance across pins (nominal ~10 kΩ at 20°C, ~4.9 kΩ at 40°C, ~2.5 kΩ at 60°C). Replace NTC sensor or heat pump assembly. Press and hold Start button for 4 seconds until display indicates '0:01', wait for evacuation pump, then power off.