Skip to content
CodesErreur.comSWISS PRO ENGINE
Core Diagnostics
DiagnosticsBrandsOEM ManualsSpecialistsAI EngineerPRO
Workshop Tools
Diagnostic ToolsNEW
Hardware interfaces & test probes
Find Rating Plate
Locate exact E-Nr, PNC & serial codes
Parts Locator
Global OEM spare parts suppliers
Community & Career
Academy & Courses
Masterclasses by senior technicians
Certification ExamsPRO
Verify your B2B technical credentials
Elite Forum
Peer-to-peer field troubleshooting
Tech Jobs
B2B recruitment & field opportunities
Leaderboard
Global ranking of verified specialists
Certified Appliance Engineering EcosystemApply for Certification →
Language Selector
ENFRDEITESPT
ENEnglishFRFrançaisDEDeutschITItalianoESEspañolPTPortuguês
Account & Access
Upgrade PRO
Back to Search
OEM VERIFIED BENCH
OFFICIAL FAULT CODETap Symbol
Siemens
Siemens // OFFICIAL DIAGNOSTIC BENCH

Siemens Dishwasher Tap Symbol

DishwasherWater Inlet Valve, Aquastop & Flowmeter
Premium built-in dishwasher with open illuminated stainless steel interior and precision spray arms
Dishwasher

Symptom / Description

FAULT

Water supply fault indicator is lit

TELEMETRY // LIVESIG: FAULT_DETECTED

Root Cause

ROOT CAUSE

Indicates an issue with the water supply. Water tap may be off, inlet hose kinked, or inlet filter blocked.

CIRCUIT // SUBSYSTEMLOGIC: ROOT_ISOLATED

Repair Instructions

UNLOCKED
1Check that the water tap is fully open. Straighten the inlet hose. Clean the filter at the connection point to the machine.
AI diagnostic workshop engine analyzing appliance circuit schematics and error telemetry in real time
AI WORKSHOP PROTOCOL ENGINE
Direct extraction from OEM factory manuals & wiring schematics

Field Actions

DISPATCH
Need Help? Call a Certified TechnicianWorldwide Siemens Parts Finder
Electrical & Safety Protocol

Always disconnect appliance from 230V/400V mains before opening panels. Use CAT III multimeter for circuit testing.

SWISS ATELIER TECHNICAL BLUEPRINT // 2026 SCHEMATIC STANDARD

Water Inlet, Aquastop & Flowmeter Loop

Inlet Solenoid Valve Y1, Reed Turbine Flowmeter & Aquastop Float S2

CALIBRATED TEST POINTS (TP1 / TP2)
ACTIVE MULTIMETER BENCH
MAIN PCB CONTROLLER32-BIT MCUFIRMWARE v26.4SOLID-STATE RELAYTRIAC TY1 // 16A 600V230V AC MAINSLINE FILTER L-NJ1J2TP1TP2PRECISION BENCH METERAUTO-RANGE ΩCAT III3.84 kΩVΩCOMINLET VALVE Y1SOLENOID Y1: 4.0 kΩFLOWMETER B1 (REED)AQUASTOP SWITCH S2: 0.0Ω
Target Component
Solenoid Valve Coil / Aquastop Pneumatic Valve
Nominal Resistance / Test Range
3.5kΩ–4.5kΩ (Standard 230V) / 2.0kΩ–4.2kΩ (Aquastop)
Test Harness Pins
Across coil spade terminals (disconnect harness first)
Diagnostic Verification Rule
OL on solenoid indicates open coil. Closed contact on float switch S2 indicates base pan leak.
CALIBRATED BENCH PROTOCOL // CAT III 600V

Workshop Verification & Safety Checklist

WORKSHOP VERIFICATION PROTOCOLWater Inlet Valve, Aquastop & FlowmeterDishwasher
2. Multimeter & Electrical Bench Tests (Ω)
MODE: OHMMETER (Ω)AUTO-RANGE
Precision digital multimeter probes measuring electrical resistance in Ohms on an appliance control board
CALIBRATED METROLOGY RESISTANCE BENCH (CAT III)
Nominal Resistance (Ω)
3.5kΩ–4.5kΩ (Standard 230V) / 2.0kΩ–4.2kΩ (Aquastop)NOMINAL
0 Ω (SHORT)CALIBRATED BAND∞ OL (OPEN)
▲ NOMINAL OPERATING WINDOW
Target Component:Solenoid Valve Coil / Aquastop Pneumatic Valve
Test Pins & Connections
PROBE (+)
PROBE (-)
Across coil spade terminals (disconnect harness first)
Tolerance & Diagnostic Criteria±10%. Open circuit (OL) indicates burned solenoid coil. Flowmeter turbine reed switch pulses on flow.
1. Pre-Intervention Electrical Safety Protocols
  • !Electrical Safety Protocol: Disconnect electrical power before touching solenoid valve coils or Aquastop connectors.
  • !Firmly shut off the domc water supply tap before unscrewing the inlet hose fitting.
  • !Check safety base drip tray for accumulated water triggering the anti-flood polystyrene float switch.
3. Preliminary Mechanical & Visual Checks
  • Remove and clean sediment and sand particles from the 3/4" inlet hose metal mesh filter.
  • Verify domestic dynamic water pressure is between 1.0 and 10.0 bar (0.1 to 1.0 MPa).
  • Inspect outer Aquastop hose jacket for expansion, pinch damage, or internal leak reservoir triggering.
Perform these diagnostic steps before triggering AI Deep Search or replacing boards.Certified Workshop Routine

Frequently Asked Questions: Siemens TAP SYMBOL

FAQ TREE
What does error code TAP SYMBOL mean on a Siemens appliance?

Siemens error code TAP SYMBOL indicates: Water supply fault indicator is lit.

What is the root cause of Siemens error code TAP SYMBOL?

The primary root cause for Siemens code TAP SYMBOL is: Indicates an issue with the water supply. Water tap may be off, inlet hose kinked, or inlet filter blocked..

How do I fix or resolve Siemens error code TAP SYMBOL?

To resolve error code TAP SYMBOL: Check that the water tap is fully open. Straighten the inlet hose. Clean the filter at the connection point to the machine.

Is it safe to clear Siemens error code TAP SYMBOL by resetting power?

Resetting power (unplugging for 5–10 minutes) clears temporary memory errors. However, if Siemens code TAP SYMBOL persists, the physical component causing Indicates an issue with the water supply. Water tap may be off, inlet hose kinked, or inlet filter blocked. must be inspected or replaced.

How do I test electrical resistance for Siemens code TAP SYMBOL using a multimeter?

Set a digital multimeter to ohms (Ω). Disconnect power and test Solenoid Valve Coil / Aquastop Pneumatic Valve across Across coil spade terminals (disconnect harness first). Expected nominal reading is 3.5kΩ–4.5kΩ (Standard 230V) / 2.0kΩ–4.2kΩ (Aquastop). Tolerance: ±10%. Open circuit (OL) indicates burned solenoid coil. Flowmeter turbine reed switch pulses on flow..

What safety protocol must be followed before servicing Siemens code TAP SYMBOL?

Standard electrical safety protocol: 1. Disconnect 230V mains power before opening panels. 2. Verify zero voltage at test points. 3. Allow hot water or heating elements to cool below 30°C before handling.

Community Verification

COMMUNITY

Did this solution resolve the issue?

SEMANTIC KNOWLEDGE GRAPH // SIEMENS

Related Siemens Dishwasher Error Codes

Diagnostic Link Mesh14 OEM Cross-References

Cross-referenced diagnostic codes for technicians inspecting similar component subsystems.

E01Dishwasher
Drainage System & Drain Pump
Siemens iQ300 / iQ500 / iQ700 / iQ800 studioLine Zeolith & varioSpeed Plus: Critical power m...
Inspect Protocol
E02Dishwasher
Drainage System & Drain Pump
Siemens iQ300 / iQ500 / iQ700 / iQ800 studioLine Zeolith & varioSpeed Plus: Auxiliary heatin...
Inspect Protocol
E03Dishwasher
Drainage System & Drain Pump
Siemens iQ300 / iQ500 / iQ700 / iQ800 studioLine Zeolith & varioSpeed Plus: Auxiliary heatin...
Inspect Protocol
E04Dishwasher
Drainage System & Drain Pump
Siemens iQ300 / iQ500 / iQ700 / iQ800 studioLine Zeolith & varioSpeed Plus: Water switch div...
Inspect Protocol
E05Dishwasher
Drainage System & Drain Pump
Siemens iQ300 / iQ500 / iQ700 / iQ800 studioLine Zeolith & varioSpeed Plus: Water switch mot...
Inspect Protocol
E06Dishwasher
Drainage System & Drain Pump
Siemens iQ300 / iQ500 / iQ700 / iQ800 studioLine Zeolith & varioSpeed Plus: Door Hall sensor...
Inspect Protocol
E07Dishwasher
NTC Temperature Sensor & Thermistor
Siemens iQ300 / iQ500 / iQ700 / iQ800 studioLine Zeolith & varioSpeed Plus: Zeolith drying f...
Inspect Protocol
E08Dishwasher
Water Level Pressure Switch & Air Dome
Siemens iQ300 / iQ500 / iQ700 / iQ800 studioLine Zeolith & varioSpeed Plus: Low water level ...
Inspect Protocol
E09Dishwasher
Drainage System & Drain Pump
Siemens iQ300 / iQ500 / iQ700 / iQ800 studioLine Zeolith & varioSpeed Plus: Heating circuit ...
Inspect Protocol
E10Dishwasher
Drainage System & Drain Pump
Siemens iQ300 / iQ500 / iQ700 / iQ800 studioLine Zeolith & varioSpeed Plus: Scale build-up o...
Inspect Protocol
E11Dishwasher
NTC Temperature Sensor & Thermistor
Siemens iQ300 / iQ500 / iQ700 / iQ800 studioLine Zeolith & varioSpeed Plus: NTC temperature ...
Inspect Protocol
E12Dishwasher
Drainage System & Drain Pump
Siemens iQ300 / iQ500 / iQ700 / iQ800 studioLine Zeolith & varioSpeed Plus: Severe lime scal...
Inspect Protocol
E13Dishwasher
NTC Temperature Sensor & Thermistor
Siemens iQ300 / iQ500 / iQ700 / iQ800 studioLine Zeolith & varioSpeed Plus: High water inlet...
Inspect Protocol
E14Dishwasher
Drainage System & Drain Pump
Siemens iQ300 / iQ500 / iQ700 / iQ800 studioLine Zeolith & varioSpeed Plus: Flowmeter turbin...
Inspect Protocol
CodesErreur.com

Premium appliance diagnostics & repair database.
Powered by AI to help certified technicians worldwide.

Trusted by professionals in CH & FR

Platform

Search DatabasePRO Diagnostic AIPRODiagnostic ToolsBrands

Workshop Tools

Brands (87)OEM ManualsFind Rating PlateParts Locator

For Technicians

SpecialistsTechnician ForumTech JobsPremium

Corporate

Terms of ServicePrivacy PolicyOfficial Swiss Repair Partner: Electroassistance
OPERATIONAL SAFETY SPECIFICATION

SAFETY DISCLAIMER

The technical information, diagnostic guides, error codes, and AI-generated suggestions provided on this website are intended exclusively for certified and qualified professionals. Appliance repair involves severe electrical hazards, high voltages, and mechanical risks that can result in fatal injury or severe property damage. If you are not a trained technician, do not attempt to repair any appliances. CodesErreur assumes no responsibility or liability for any damage, injury, or consequential losses resulting from the use of the information provided on this platform. You use all information entirely at your own risk.

© 2026 CodesErreur. All rights reserved.