Whirlpool F7E2 — Refrigerator / Freezer
[ACTIVE]Whirlpool 6th Sense Dual-Cool & Total NoFrost Refrigerator: Diagnostic code F7E2 indicates dual-evaporator fresh food compartment defrost heater circuit open; upper coil frosts over completely.
On Whirlpool refrigerators (Whirlpool 6th Sense algorithms and WAVE / L1373 electronic platform): Open resistance trace on fresh food aluminum foil heater or blown inline thermal link. Nominal resistance: 80–150 Ω (115V) or 600–900 Ω (230V).
Disconnect power. Remove fresh food rear tower. Measure resistance across heater connector pins: expect 80–150 Ω (115V) or 600–900 Ω (230V). If infinite Ω, replace fresh food evaporator foil heater assembly. Press and hold the Filter Reset or Alarm Silence touch pad for 5 seconds until the confirmation chime sounds.