Zerowatt E13 — Dryer
[ACTIVE]Zerowatt ZTD Condenser & Heat-Pump Tumble Dryer: Condensate collection container full alert E13; water reservoir float switch trips and halts program execution.
On Zerowatt tumble dryers utilizing ZTD condensation airflow duct system, bi-metal safety thermal cut-out, and electromechanical program timer: Water container completely filled with extracted condensate, stuck microswitch lever, or slime coating the float.
Empty condensate drawer completely and re-insert firmly until it clicks. If code persists empty, clean sump float switch chamber in lower rear. Rotate dial to Off, press Start and Low Heat buttons for 5 seconds until the buzzer chirps twice, then release and turn to Off.