Zerowatt E3 — Dishwasher
[ACTIVE]Zerowatt ZD / Space / CompactLine Dishwasher: Drain evacuation timeout E3; water remains in sump after 240 seconds of drain pump operation.
On Zerowatt dishwashers powered by CompactLine hydraulic wash circuit, mechanical water pressure regulation, and micro-switch anti-flood float protection: Blocked microfilter, foreign body (glass shard, olive pit) jamming drain impeller, kinked hose, or open pump motor (~160–220 Ω).
Remove sump filters and clean thoroughly. Check drain pump impeller for free rotation. Measure drain pump winding resistance (~160–220 Ω). Hold Start button for 5 seconds until the program run LED stops blinking, close the door to complete drain, then power off.