Zerowatt E4 — Dishwasher
[ACTIVE]Zerowatt ZD / Space / CompactLine Dishwasher: Anti-flood leak protection triggered E4; float switch in the bottom chassis pan rises and engages emergency drain.
On Zerowatt dishwashers featuring CompactLine hydraulic wash circuit, mechanical water pressure regulation, and micro-switch anti-flood float protection: Leaking sump seal, split recirculation pump casing, door perimeter gasket wear, or cracked fill hose connection.
Disconnect mains power. Sponge out water from bottom collection tray. Inspect sump gasket, pump hose clamps, and tub seams with dry paper. Test anti-flood microswitch continuity with a multimeter. Hold Start button for 5 seconds until the program run LED stops blinking, close the door to complete drain, then power off.