Zerowatt F3 — Dryer
[ACTIVE]Zerowatt ZTD Condenser & Heat-Pump Tumble Dryer: Compressor discharge pipe high-temperature limit exceeded F3; temperature on discharge line exceeds 115°C.
On Zerowatt dryers utilizing ZTD condensation airflow duct system, bi-metal safety thermal cut-out, and electromechanical program timer: Low refrigerant charge causing superheat, blocked heat exchanger coil, or defective discharge NTC sensor.
Allow system to cool. Thoroughly clean heat exchanger and filters. Measure discharge sensor (~10 kΩ at 25°C). Inspect sealed system for oil trace (leak). Rotate dial to Off, press Start and Low Heat buttons for 5 seconds until the buzzer chirps twice, then release and turn to Off.