Zerowatt F7 — Hob
[ACTIVE]Zerowatt ZH Induction & Vitroceramic Cooktop: Mains supply frequency out of limits F7; AC power line frequency falls outside 47 Hz–63 Hz operating window.
On Zerowatt cooktops utilizing ZH induction & vitroceramic heating elements, bi-metallic energy regulator controls, and residual heat indicators: Unstable generator or solar inverter power supply, severe grid harmonic distortion, or failed zero-crossing detection circuit on board.
Measure AC line frequency with digital multimeter (must read 50.0 Hz or 60.0 Hz ±1 Hz). If running on generator, adjust governor. Replace filter board if grid is normal. Wipe glass dry, switch off the hob fuse breaker for 30 seconds, restore circuit and hold Key Symbol for 4 seconds.