Zerowatt F9 — Hob
[ACTIVE]Zerowatt ZH Induction & Vitroceramic Cooktop: Induction coil current sensor calibration failure F9; current transformer sensing circuit fails zero-offset balance test at power up.
On Zerowatt cooktops utilizing ZH induction & vitroceramic heating elements, bi-metallic energy regulator controls, and residual heat indicators: Defective current transformer on power PCB, leaky shunt resistor, or cracked ferrite core on measuring coil.
Turn off breaker for 5 minutes. If code returns upon energization, inspect power board current sensing stage or replace affected generator board. Wipe glass dry, switch off the hob fuse breaker for 30 seconds, restore circuit and hold Key Symbol for 4 seconds.