Frigidaire • Central Diagnostic Dictionary
113 Verified Codes in Database

Frigidaire Error Codes & Diagnostics

Access our premium database of error codes, common faults, and professional repair solutions for Frigidaire appliances.

Luxury front-loading washing machine in brushed titanium with illuminated dark glass drum
CodeAppliancesFault / DiagnosticsRepair InstructionsAction
i10
Dishwasher
Drainage System & Drain Pump

Frigidaire Gallery / OrbitClean Wash Dishwasher: Water fill timeout error i10; appliance fails to reach operational water fill level within 180 seconds.

On Frigidaire (Frigidaire Gallery / OrbitClean Wash Dishwasher) models: Closed water tap, kinked supply hose, clogged inlet filter, defective AquaStop solenoid valve (nominal 3.8–4.4 kΩ), or blocked pressure sensor hose.

Check water tap pressure. Clean mesh filter in AquaStop coupling. Measure solenoid valve coil resistance with multimeter (3.8–4.4 kΩ). Press and hold Cancel / Drain for 3 seconds, or cycle the control lock for 5 seconds to clear persistent memory fault log.

Diagnose
i11
Dishwasher
Drainage System & Drain Pump

Frigidaire Gallery / OrbitClean Wash Dishwasher: Water fill timeout during active wash phase i11; flowmeter detects inadequate water intake volume.

On Frigidaire (Frigidaire Gallery / OrbitClean Wash Dishwasher) models: Low dynamic water pressure (< 0.8 bar), water softener resin matrix restricting flow, or failing flowmeter impeller sensor.

Verify dynamic water flow rate into bucket (> 5 L/min). Inspect flowmeter reed switch wiring and verify pulse signal on oscilloscope/multimeter. Press and hold Cancel / Drain for 3 seconds, or cycle the control lock for 5 seconds to clear persistent memory fault log.

Diagnose
i20
Dishwasher
Drainage System & Drain Pump

Frigidaire Gallery / OrbitClean Wash Dishwasher: Water drain timeout error i20; wash water remains in sump after 90 seconds of drain pump activation.

On Frigidaire (Frigidaire Gallery / OrbitClean Wash Dishwasher) models: Clogged fine mesh filter in tub sump, lemon seeds or broken glass jammed in drain impeller, kinked waste hose, or drain pump coil open (160–220 Ω).

Remove sump filter cylinders and clean under hot water. Check drain pump impeller through sump cavity. Measure pump motor resistance (160–220 Ω). Press and hold Cancel / Drain for 3 seconds, or cycle the control lock for 5 seconds to clear persistent memory fault log.

Diagnose
i22
Dishwasher
Drainage System & Drain Pump

Frigidaire Gallery / OrbitClean Wash Dishwasher: Siphon pressure sensor alarm i22; analog sensor detects back-pressure after drain cycle completes.

On Frigidaire (Frigidaire Gallery / OrbitClean Wash Dishwasher) models: Kitchen sink siphon spigot not drilled out on new installation, grease blockage in drain hose non-return flap, or restricted wall pipe.

Inspect connection spigot under kitchen sink (ensure plastic membrane was drilled out). Clean rubber non-return flap in sump outlet. Press and hold Cancel / Drain for 3 seconds, or cycle the control lock for 5 seconds to clear persistent memory fault log.

Diagnose
i23
Dishwasher
Drainage System & Drain Pump

Frigidaire Gallery / OrbitClean Wash Dishwasher: Drain pump triac failure or feedback sensing mismatch i23 on main electronic motherboard.

On Frigidaire (Frigidaire Gallery / OrbitClean Wash Dishwasher) models: Triac destroyed by short-circuited drain pump stator coil, moisture on pump spade terminals, or open sensing resistor on motherboard.

Measure drain pump coil resistance (must be 160–220 Ω; if < 150 Ω replace pump first!). Inspect PCB for burned triac package. Press and hold Cancel / Drain for 3 seconds, or cycle the control lock for 5 seconds to clear persistent memory fault log.

Diagnose
i24
Dishwasher
Drainage System & Drain Pump

Frigidaire Gallery / OrbitClean Wash Dishwasher: Drain pump circuit feedback incongruence i24; drain pump current draws outside operating window.

On Frigidaire (Frigidaire Gallery / OrbitClean Wash Dishwasher) models: Pump running dry with zero hydraulic load (airlock), broken impeller decoupled from shaft, or high-resistance spade terminal connection.

Verify impeller is firmly fixed to motor shaft. Pour 2 liters of water into sump to prime pump cavity. Check spade crimp terminals. Press and hold Cancel / Drain for 3 seconds, or cycle the control lock for 5 seconds to clear persistent memory fault log.

Diagnose
i30
Dishwasher
Drainage System & Drain Pump

Frigidaire Gallery / OrbitClean Wash Dishwasher: AquaControl flood protection active i30; base drip tray float triggered, drain pump runs continuously.

On Frigidaire (Frigidaire Gallery / OrbitClean Wash Dishwasher) models: Internal water leak onto bottom pan, leaking door lower perimeter gasket, split circulation pump casing, or overflowing dispenser.

Disconnect power and shut water tap. Sponge out water from metal base pan. Inspect sump gasket, hoses, and door bottom seal for moisture. Press and hold Cancel / Drain for 3 seconds, or cycle the control lock for 5 seconds to clear persistent memory fault log.

Diagnose
i40
Dishwasher
Drainage System & Drain Pump

Frigidaire Gallery / OrbitClean Wash Dishwasher: Analog pressure sensor general malfunction i40; uncalibrated or out-of-bounds pressure reading.

On Frigidaire (Frigidaire Gallery / OrbitClean Wash Dishwasher) models: Fat deposit clogging pressure sensor trap at bottom of sump, defective transducer diaphragm, or broken 5V DC/GND/Signal wiring harness.

Clean sump pressure cavity with hot water and degreaser syringe. Measure 5V DC supply at sensor plug. Replace analog pressure sensor if faulty. Press and hold Cancel / Drain for 3 seconds, or cycle the control lock for 5 seconds to clear persistent memory fault log.

Diagnose
i41
Dishwasher
Water Level Pressure Switch & Air Dome

Frigidaire Gallery / OrbitClean Wash Dishwasher: Analog pressure sensor signal out of range i41; frequency or voltage exceeds operating window.

On Frigidaire (Frigidaire Gallery / OrbitClean Wash Dishwasher) models: Pressure switch internal piezoelectric element failure, water entered sensor housing, or corroded connector terminal pins.

Inspect pressure switch pins for green corrosion. Measure output signal with multimeter. Replace analog pressure transducer if defective. Press and hold Cancel / Drain for 3 seconds, or cycle the control lock for 5 seconds to clear persistent memory fault log.

Diagnose
i43
Dishwasher
Water Level Pressure Switch & Air Dome

Frigidaire Gallery / OrbitClean Wash Dishwasher: Dynamic water level fluctuations alarm i43; abnormal pressure oscillations detected during circulation.

On Frigidaire (Frigidaire Gallery / OrbitClean Wash Dishwasher) models: Spray arms jammed against tall plates or cutlery, lower spray arm clogged with lemon seeds, or foaming from rinse aid overfill.

Ensure upper and lower spray arms rotate freely by hand. Clean clogged spray arm nozzle orifices with a needle. Check for excessive foam. Press and hold Cancel / Drain for 3 seconds, or cycle the control lock for 5 seconds to clear persistent memory fault log.

Diagnose
i44
Dishwasher
Drainage System & Drain Pump

Frigidaire Gallery / OrbitClean Wash Dishwasher: Pressure sensor zero calibration error at cycle start i44; sensor fails to establish atmospheric zero reference.

On Frigidaire (Frigidaire Gallery / OrbitClean Wash Dishwasher) models: Water remaining in tub from previous cancelled cycle, pressure sensor pipe holding hydraulic head, or drifted sensor calibration.

Bail out all standing water from sump with a sponge. Blow gently into pressure sensor rubber hose to equalize pressure. Press and hold Cancel / Drain for 3 seconds, or cycle the control lock for 5 seconds to clear persistent memory fault log.

Diagnose
i50
Dishwasher
Drainage System & Drain Pump

Frigidaire Gallery / OrbitClean Wash Dishwasher: Circulation wash pump motor general alarm i50; wash motor fails to circulate water through spray arms.

On Frigidaire (Frigidaire Gallery / OrbitClean Wash Dishwasher) models: Circulation pump motor capacitor failed (if single-phase), BLDC inverter stator winding open, jammed motor rotor, or triac/inverter driver fault.

Measure motor winding resistance across phases (balanced 40–90 Ω on BLDC motor). Check run capacitor (~2.5–3.5 µF) if fitted. Ensure free rotation. Press and hold Cancel / Drain for 3 seconds, or cycle the control lock for 5 seconds to clear persistent memory fault log.

Diagnose
i51
Dishwasher
Drainage System & Drain Pump

Frigidaire Gallery / OrbitClean Wash Dishwasher: Circulation pump motor triac short circuit i51 on main motherboard; motor runs uncontrolled at full speed.

On Frigidaire (Frigidaire Gallery / OrbitClean Wash Dishwasher) models: Circulation pump motor winding internal short circuit causing power triac breakdown, or water splashing onto main PCB connectors.

Measure circulation pump stator resistance before replacing PCB. Replace damaged motor and replace or repair triac circuit. Press and hold Cancel / Drain for 3 seconds, or cycle the control lock for 5 seconds to clear persistent memory fault log.

Diagnose
i52
Dishwasher
Drainage System & Drain Pump

Frigidaire Gallery / OrbitClean Wash Dishwasher: Circulation pump motor tachometer signal missing i52; motor starts, vibrates, and shuts down after 3 seconds.

On Frigidaire (Frigidaire Gallery / OrbitClean Wash Dishwasher) models: Tachometer generator coil open circuit (nominal 200–260 Ω on tachometer equipped models), detached rear magnet, or broken wiring in harness.

Measure tachometer coil resistance across motor tachometer terminals (200–260 Ω). Check magnet integrity on rear rotor shaft. Press and hold Cancel / Drain for 3 seconds, or cycle the control lock for 5 seconds to clear persistent memory fault log.

Diagnose
i53
Dishwasher
Drainage System & Drain Pump

Frigidaire Gallery / OrbitClean Wash Dishwasher: Circulation pump triac sensing circuit faulty i53; voltage feedback out of range on motherboard.

On Frigidaire (Frigidaire Gallery / OrbitClean Wash Dishwasher) models: Sensing divider resistor drifted on main PCB, cracked solder joints around triac terminals, or optocoupler feedback failure.

Inspect main PCB circuit around circulation pump triac. Resolder cracked joints or replace main electronic control board. Press and hold Cancel / Drain for 3 seconds, or cycle the control lock for 5 seconds to clear persistent memory fault log.

Diagnose
i54
Dishwasher
Drainage System & Drain Pump

Frigidaire Gallery / OrbitClean Wash Dishwasher: Circulation pump motor rotor blocked or mechanically jammed i54; wash pump draws locked rotor current.

On Frigidaire (Frigidaire Gallery / OrbitClean Wash Dishwasher) models: Toothpick, olive pit, or broken glass shard jammed between pump impeller and casing, or seized ceramic rotor bushings.

Dismantle circulation pump head casing and clear obstruction from impeller vanes. Verify free manual rotation before reassembly. Press and hold Cancel / Drain for 3 seconds, or cycle the control lock for 5 seconds to clear persistent memory fault log.

Diagnose
i55
Dishwasher
Drainage System & Drain Pump

Frigidaire Gallery / OrbitClean Wash Dishwasher: Circulation pump inverter overcurrent detected i55; phase current exceeds peak threshold during wash.

On Frigidaire (Frigidaire Gallery / OrbitClean Wash Dishwasher) models: Stator winding phase-to-phase partial short circuit, failing IGBT inverter bridge transistor, or high water viscosity from detergent gelatin.

Measure winding resistance across all 3 phases (must be strictly balanced within 5%: nominal ~45–65 Ω). Replace pump if unbalanced. Press and hold Cancel / Drain for 3 seconds, or cycle the control lock for 5 seconds to clear persistent memory fault log.

Diagnose
i56
Dishwasher
NTC Temperature Sensor & Thermistor

Frigidaire Gallery / OrbitClean Wash Dishwasher: Circulation pump inverter thermal cutoff / motor overheating i56; internal thermistor exceeds safety cutoff.

On Frigidaire (Frigidaire Gallery / OrbitClean Wash Dishwasher) models: Extended cycle with hot water intake (> 65°C), inadequate motor cooling in enclosed bottom base, or heavy bearing friction.

Allow motor to cool down for 30 minutes. Check inlet water temperature (max 60°C). Inspect motor bearings for friction or seizing. Press and hold Cancel / Drain for 3 seconds, or cycle the control lock for 5 seconds to clear persistent memory fault log.

Diagnose
i57
Dishwasher
Drainage System & Drain Pump

Frigidaire Gallery / OrbitClean Wash Dishwasher: Circulation pump inverter phase current imbalance i57; unequal current distribution across stator coils.

On Frigidaire (Frigidaire Gallery / OrbitClean Wash Dishwasher) models: High-resistance connection on one motor phase pin, partial insulation breakdown between windings, or defective inverter driver channel.

Disconnect motor plug and inspect pins for discoloration. Measure DC resistance of all 3 phase pairs with high-precision multimeter. Press and hold Cancel / Drain for 3 seconds, or cycle the control lock for 5 seconds to clear persistent memory fault log.

Diagnose
i58
Dishwasher
Drainage System & Drain Pump

Frigidaire Gallery / OrbitClean Wash Dishwasher: Circulation pump motor phase disconnected or stator open circuit i58; inverter senses missing phase current.

On Frigidaire (Frigidaire Gallery / OrbitClean Wash Dishwasher) models: Cut wire in three-phase motor cable harness, terminal pin backed out of plastic housing, or open stator winding inside motor.

Test electrical continuity of each phase lead from inverter board to motor terminals (< 0.5 Ω). Replace motor if winding is open (infinite Ω). Press and hold Cancel / Drain for 3 seconds, or cycle the control lock for 5 seconds to clear persistent memory fault log.

Diagnose
i59
Dishwasher
Water Level Pressure Switch & Air Dome

Frigidaire Gallery / OrbitClean Wash Dishwasher: Circulation pump motor speed runaway or tachometer mismatch i59; rotor speed exceeds command target.

On Frigidaire (Frigidaire Gallery / OrbitClean Wash Dishwasher) models: Cavitation in pump chamber caused by zero water intake or excessive foam, loose tachometer magnet, or inverter PWM control breakdown.

Check tub water level (must submerge sump filter base). Check for excessive foam from detergent. Verify tachometer magnet mounting. Press and hold Cancel / Drain for 3 seconds, or cycle the control lock for 5 seconds to clear persistent memory fault log.

Diagnose
SY EF
Refrigerator / Freezer
Refrigeration Compressor, Defrost Heater & PTC Relay

Frigidaire Gallery / EvenTemp / PureSource Refrigerator: System evaporator fan circuit failure SY EF; electronic control module detects no rotation speed feedback from evaporator blower.

On Frigidaire (Frigidaire Gallery / EvenTemp / PureSource Refrigerator) models: Ice accumulation freezing the fan blades, defective 12V DC brushless motor windings, severed connector lead, or blown fan driver IC on main motherboard.

Remove freezer back panel. Spin fan blade to verify free rotation. Measure 12V DC across fan red and black wires, and verify pulsing feedback on yellow wire. Press and hold Cancel / Drain for 3 seconds, or cycle the control lock for 5 seconds to clear persistent memory fault log.

Diagnose
5Y EF
Refrigerator / Freezer
Refrigeration Compressor, Defrost Heater & PTC Relay

Frigidaire Gallery / EvenTemp / PureSource Refrigerator: System evaporator fan circuit failure 5Y EF; alternative 7-segment display rendering of SY EF error code on user console.

On Frigidaire (Frigidaire Gallery / EvenTemp / PureSource Refrigerator) models: Ice accumulation freezing the fan blades, defective 12V DC brushless motor windings, severed connector lead, or blown fan driver IC on main motherboard.

Inspect evaporator fan behind freezer back wall. Remove frost with warm air. Measure 12V DC motor supply and verify tacho feedback signal. Press and hold Cancel / Drain for 3 seconds, or cycle the control lock for 5 seconds to clear persistent memory fault log.

Diagnose
← Previous PagePage 4 of 4 (113 results)
Next Page →

Frigidaire — Complete Error Code Catalog

102 Verified Error Codes

Server-side index of all verified manufacturer error codes for technicians and automated crawlers.

Dishwasher25

i5Ai5Bi5Ci5Di10i11i20i22i23i24i30i40i41i43i44i50i51i52i53i54i55i56i57i58i59

Washing Machine24

E3AE5AE5CE5DE10E11E12E13E20E21E22E23E24E25E33E34E35E38E40E41E42E43E44E45

Tumble Dryer25

E30E31E32E50E51E52E53E54E57E58E59E60E61E62E63E70E71E72E73E80E90E91E92E93EH0

Oven / Microwave12

F101F102F103F104F105F106F107F108F109F110F111F112

Refrigerator / Freezer16

E01E02E03E04E05E06E07F1F2F3F4F5F6F7SY EF5Y EF
CodesErreur.com

Premium appliance diagnostics & repair database.
Powered by AI to help certified technicians worldwide.

Trusted by professionals in CH & FR

Platform

Search DatabasePRO Diagnostic AIPRODiagnostic ToolsBrands

Workshop Tools

Brands (87)OEM ManualsFind Rating PlateParts Locator

For Technicians

SpecialistsTechnician ForumTech JobsPremium

Corporate

Terms of ServicePrivacy PolicyOfficial Swiss Repair Partner: Electroassistance
OPERATIONAL SAFETY SPECIFICATION

SAFETY DISCLAIMER

The technical information, diagnostic guides, error codes, and AI-generated suggestions provided on this website are intended exclusively for certified and qualified professionals. Appliance repair involves severe electrical hazards, high voltages, and mechanical risks that can result in fatal injury or severe property damage. If you are not a trained technician, do not attempt to repair any appliances. CodesErreur assumes no responsibility or liability for any damage, injury, or consequential losses resulting from the use of the information provided on this platform. You use all information entirely at your own risk.

© 2026 CodesErreur. All rights reserved.

Official Swiss Repair Partner: Electroassistance Terms of Service Privacy Policy