Hisense • Central Diagnostic Dictionary
144 Verified Codes in Database

Hisense Error Codes & Diagnostics

Access our premium database of error codes, common faults, and professional repair solutions for Hisense appliances.

Luxury front-loading washing machine in brushed titanium with illuminated dark glass drum
CodeAppliancesFault / DiagnosticsRepair InstructionsAction
E0
Refrigerator / Freezer
NTC Temperature Sensor & Thermistor

Ambient temperature sensor fault. Diagnostic error code E0 reported on Hisense Refrigerator.

On Hisense Refrigerator: The sensor measuring the room temperature is faulty, which can affect the cooling cycle.

On Hisense Refrigerator: Requires professional service to replace the ambient temperature sensor.

Diagnose
E01
Dishwasher
Drainage System & Drain Pump

Hisense AutoDry / Smart Wash / PureClean Dishwasher: Water fill timeout E01; sump does not achieve required operating water volume within 4 minutes of program start.

On Hisense dishwashers featuring Dual-inverter circulation and drain pumps, AutoDry automatic door release, and 16 place settings flexible rack system: Closed isolation valve tap, sediment-choked inlet filter screen, or open AquaStop solenoid valve coil (~3.6–4.8 kΩ).

Ensure water supply tap is fully open (>8 L/min). Clean inlet hose filter mesh. Measure AquaStop solenoid coil resistance (~3.6–4.8 kΩ). Open door slightly, press and hold Programme and Start buttons for 4 seconds until the display shows '0:00', close door to drain.

Diagnose
E01
Tumble Dryer
General System & Mechanical Integration

Hisense Allergy Care / Heat Pump / ConnectLife Tumble Dryer: Lint filter air flow restriction E01; drying cycle halts or extends drastically due to choked process air circulation.

On Hisense tumble dryers equipped with Closed thermodynamic heat pump circuit, dual lint filtering screens, and anti-crease bidirectional drum tumbling: Heavy lint accumulation in door filter mesh, micro-fiber clogging in bottom plinth filter, or exhaust duct restriction.

Extract and wash door lint filters under warm running water; allow to dry completely. Vacuum the lower plinth housing and verify process fan free movement. Rotate dial to Off. Press and hold Start/Pause and Anti-Crease buttons for 5 seconds until the acoustic chime sounds, then restart.

Diagnose
E01
Hob / Cooktop
Drive Motor, Inverter & Tachometer Sensor

Hisense Rapid Boil / ConnectLife / Smart Zone Induction Cooktop: Touch interface to induction power board link failure E01; display zones flash error and power level sliders are disabled.

On Hisense cooktops with Smart Zone automatic pan detection, Rapid Boil power boost generator, and touch-slide individual zone controls: Loosened data ribbon connecting capacitive touch interface to lower power module, pin oxidation, or lost +5V DC bus voltage.

Disconnect mains power. Unseat cooktop from countertop; inspect and firmly reseat ribbon connector between touch PCB and inverter board. Measure 5V DC power bus. Wipe glass clean and dry. Switch off breaker on main board for 60 seconds, restore power and touch Child Lock sensor for 4 seconds.

Diagnose
E01
Oven / Microwave
NTC Temperature Sensor & Thermistor

Hisense Even Bake / Steam Add Plus / PureCook Built-in Oven: Cavity temperature sensor fault E01; oven display shows error immediately upon selecting any bake or roast mode.

On Hisense ovens utilizing Even Bake rounded cavity design inspired by wood-fired ovens, Steam Add Plus injection, and Air Fry technology: PT1000 platinum RTD probe or high-temp NTC sensor open circuit (~1090 Ω at 25°C), shorted probe wire, or loose harness connector.

Disconnect oven power. Measure sensor resistance at electronic board terminals: expected ~1090 Ω at 25°C (~1650 Ω at 180°C). Replace sensor if reading is open or shorted. Set function knob to 0. Cut off mains electricity at fuse board for 60 seconds, restore power and configure digital clock.

Diagnose
E01
Refrigerator / Freezer
Refrigeration Compressor, Defrost Heater & PTC Relay

Hisense PureFlat / Multi Air Flow / Total No Frost Refrigerator: Fresh food compartment NTC temperature sensor fault E01; cabinet temperature fluctuates erratically or food freezes on shelves.

On Hisense refrigeration units featuring PureFlat seamless flat-door design, Multi Air Flow columns, electronic dual-temperature zones, and inverter compressor: NTC sensor open circuit or shorted (~5–10 kΩ at 25°C, ~13–16 kΩ at 4°C), wire harness chaffed behind liner, or water in plug.

Disconnect sensor from main control board. Measure resistance: expected ~13–16 kΩ at 4°C (~5–10 kΩ at 25°C). Replace clipped sensor with hermetic splice kit if drifted. Press and hold Super Cool and Super Freeze buttons simultaneously for 6 seconds until display flashes and clears fault code history.

Diagnose
E01
Washing Machine
Drive Motor, Inverter & Tachometer Sensor

Hisense PureJet / AutoDosing / ConnectLife Series Washer: Door interlock error E01; appliance refuses to commence wash cycle because door lock contact is not confirmed closed.

On Hisense washing machines featuring PureJet high-pressure water dissolved wash, inverter drive motor, and ConnectLife IoT cloud diagnostics: Defective door latch mechanism, misaligned strike pin, or open PTC solenoid coil (~800–1250 Ω).

Inspect door latch alignment. Disconnect mains and test door lock PTC resistance between terminals (~800–1250 Ω). Check wiring harness continuity. Turn power off with Power button. Press and hold Start/Pause for 5 seconds to clear cycle memory. Power on and select new cycle.

Diagnose
E02
Dishwasher
Drainage System & Drain Pump

Hisense AutoDry / Smart Wash / PureClean Dishwasher: Waste water draining fault E02; wash sump retains dirty water after 3 minutes of continuous drain pump operation.

On Hisense dishwashers utilizing Dual-inverter circulation and drain pumps, AutoDry automatic door release, and 16 place settings flexible rack system: Bone or broken glass chip jamming drain pump impeller, blocked sink trap siphon, or open pump motor coil (~160–240 Ω).

Remove fine micro-filter assembly. Check drain pump impeller cavity under white plastic cover for glass shards. Measure pump resistance (~160–240 Ω). Open door slightly, press and hold Programme and Start buttons for 4 seconds until the display shows '0:00', close door to drain.

Diagnose
E02
Tumble Dryer
Drainage System & Drain Pump

Hisense Allergy Care / Heat Pump / ConnectLife Tumble Dryer: Condensate drain pump timeout or float trip E02; appliance triggers water tank full alarm despite empty collection tank.

On Hisense dryers featuring Closed thermodynamic heat pump circuit, dual lint filtering screens, and anti-crease bidirectional drum tumbling: Blocked condensate sump chamber, stuck polystyrene float switch, kinked discharge hose, or burnt pump coil (~750–950 Ω).

Access bottom rear/side sump; clear sludge around float switch. Measure pump resistance across terminals (~750–950 Ω at 20°C). Verify float switch clicks (<0.5 Ω closed). Rotate dial to Off. Press and hold Start/Pause and Anti-Crease buttons for 5 seconds until the acoustic chime sounds, then restart.

Diagnose
E02
Hob / Cooktop
Electronic Control Board (PCB) & Bus Communications

Hisense Rapid Boil / ConnectLife / Smart Zone Induction Cooktop: Induction coil pan detection failure E02; selected zone refuses to energize cookware, displays missing pot symbol, and turns off.

On Hisense cooktops with Smart Zone automatic pan detection, Rapid Boil power boost generator, and touch-slide individual zone controls: Open-circuit in copper litz coil winding (<0.3 Ω normal), cracked ferrite concentrator bars underneath coil, or loose coil terminal screws.

Check coil continuity with ohmmeter: must be <0.3 Ω across coil eyelet leads. Inspect ferrite core bars for physical cracks. Tighten Torx terminal screws to 2.5 Nm. Wipe glass clean and dry. Switch off breaker on main board for 60 seconds, restore power and touch Child Lock sensor for 4 seconds.

Diagnose
E02
Oven / Microwave
Drive Motor, Inverter & Tachometer Sensor

Hisense Even Bake / Steam Add Plus / PureCook Built-in Oven: Pyrolytic door lock mechanism failure E02; door fails to lock during self-clean cycle or remains jammed shut after cooling.

On Hisense ovens with Even Bake rounded cavity design inspired by wood-fired ovens, Steam Add Plus injection, and Air Fry technology: Stripped gear in motorized cam lock actuator (~3.2–4.5 kΩ coil), bent latch hook, or defective lock position microswitches.

Check lock motor winding resistance (~3.2–4.5 kΩ). Inspect cam gear assembly and test microswitch continuity in locked (<0.5 Ω) and unlocked states. Set function knob to 0. Cut off mains electricity at fuse board for 60 seconds, restore power and configure digital clock.

Diagnose
E02
Refrigerator / Freezer
Refrigeration Compressor, Defrost Heater & PTC Relay

Hisense PureFlat / Multi Air Flow / Total No Frost Refrigerator: Freezer compartment temperature sensor defect E02; freezer warm alert triggers and compressor runs continuously without stopping.

On Hisense refrigeration units with PureFlat seamless flat-door design, Multi Air Flow columns, electronic dual-temperature zones, and inverter compressor: Open or shorted freezer cavity NTC thermistor (~5–10 kΩ at 25°C, ~30–35 kΩ at -18°C), or sensor cable grounded to chassis.

Test sensor resistance across board terminals: expected ~30–35 kΩ at -18°C (~5–10 kΩ at 25°C). Replace defective freezer sensor module with OEM spare. Press and hold Super Cool and Super Freeze buttons simultaneously for 6 seconds until display flashes and clears fault code history.

Diagnose
E02
Washing Machine
Water Level Pressure Switch & Air Dome

Hisense PureJet / AutoDosing / ConnectLife Series Washer: Water intake timeout E02; drum water level does not reach target threshold within 5 minutes of fill valve activation.

On Hisense washing machines utilizing PureJet high-pressure water dissolved wash, inverter drive motor, and ConnectLife IoT cloud diagnostics: Low water supply pressure (<0.8 bar), blocked inlet filter screen, or open dual solenoid valve coil (~3.6–4.8 kΩ).

Check water tap flow rate (>10 L/min). Clean the inlet hose filter mesh. Measure resistance across solenoid valve coils (~3.6–4.8 kΩ). Turn power off with Power button. Press and hold Start/Pause for 5 seconds to clear cycle memory. Power on and select new cycle.

Diagnose
E03
Dishwasher
NTC Temperature Sensor & Thermistor

Hisense AutoDry / Smart Wash / PureClean Dishwasher: Water heating failure E03; wash bath fails to attain wash setpoint temperature within 20 minutes of heater activation.

On Hisense dishwashers featuring Dual-inverter circulation and drain pumps, AutoDry automatic door release, and 16 place settings flexible rack system: Open flow-through tubular heating element (~25–32 Ω), tripped non-resettable thermal fuse, or open wash NTC sensor (~10–12 kΩ at 25°C).

Measure flow-through heater resistance across terminals (~25–32 Ω). Check insulation to ground (>2 MΩ). Measure wash NTC probe (~10–12 kΩ at 25°C). Open door slightly, press and hold Programme and Start buttons for 4 seconds until the display shows '0:00', close door to drain.

Diagnose
E03
Tumble Dryer
Heating Element, Thermostat & Safety Fuse

Hisense Allergy Care / Heat Pump / ConnectLife Tumble Dryer: Heating circuit malfunction E03; drum turns continuously but process air remains cold and laundry stays completely wet.

On Hisense dryers with Closed thermodynamic heat pump circuit, dual lint filtering screens, and anti-crease bidirectional drum tumbling: Open heater spiral resistance (~22–34 Ω), open safety Klixon thermostat on heater duct, or defective control board heater relay.

Disconnect power. Measure resistance across heater element terminals (~22–34 Ω). Check inline safety Klixon continuity (<0.5 Ω). Inspect control board PCB heater solder pads. Rotate dial to Off. Press and hold Start/Pause and Anti-Crease buttons for 5 seconds until the acoustic chime sounds, then restart.

Diagnose
E03
Hob / Cooktop
Heating Element, Thermostat & Safety Fuse

Hisense Rapid Boil / ConnectLife / Smart Zone Induction Cooktop: Power module IGBT inverter transistor short circuit E03; appliance trips home breaker instantly when zone power is dialed up.

On Hisense cooktops with Smart Zone automatic pan detection, Rapid Boil power boost generator, and touch-slide individual zone controls: Collector-Emitter thermal punch-through (<1 Ω) in one or more 1200V IGBT transistors or shorted bridge rectifier.

Measure C-E resistance of all IGBTs on aluminum heatsink with diode tester: low resistance (<100 Ω) confirms puncture. Replace blown IGBTs and gate drive resistors or swap power board. Wipe glass clean and dry. Switch off breaker on main board for 60 seconds, restore power and touch Child Lock sensor for 4 seconds.

Diagnose
E03
Oven / Microwave
Drive Motor, Inverter & Tachometer Sensor

Hisense Even Bake / Steam Add Plus / PureCook Built-in Oven: Tangential cooling fan motor failure E03; electronic safety cuts off heating to prevent control panel and casing overheating.

On Hisense ovens with Even Bake rounded cavity design inspired by wood-fired ovens, Steam Add Plus injection, and Air Fry technology: Seized tangential fan roller bearings, burned motor winding (~160–240 Ω), or failed Hall effect tachometer feedback sensor.

Inspect fan rotor for mechanical binding. Measure motor coil resistance (~160–240 Ω). Verify tachometer signal pulses with oscilloscope or multimeter frequency mode. Set function knob to 0. Cut off mains electricity at fuse board for 60 seconds, restore power and configure digital clock.

Diagnose
E03
Refrigerator / Freezer
Refrigeration Compressor, Defrost Heater & PTC Relay

Hisense PureFlat / Multi Air Flow / Total No Frost Refrigerator: Defrost termination evaporator sensor fault E03; evaporator coil freezes solid with ice, choking air circulation vents.

On Hisense refrigeration units with PureFlat seamless flat-door design, Multi Air Flow columns, electronic dual-temperature zones, and inverter compressor: Defrost NTC sensor clipped to evaporator header pipe open (~5 kΩ at 25°C, ~16 kΩ at 0°C), preventing defrost cycle execution.

Manually defrost evaporator using steam/heat gun. Measure sensor resistance: expected ~16.3 kΩ in iced water (0°C). Replace sensor firmly clipped to aluminum tube. Press and hold Super Cool and Super Freeze buttons simultaneously for 6 seconds until display flashes and clears fault code history.

Diagnose
E03
Washing Machine
Drainage System & Drain Pump

Hisense PureJet / AutoDosing / ConnectLife Series Washer: Drainage timeout error E03; waste wash water remains in tub after 4 minutes of drain pump activation.

On Hisense washing machines featuring PureJet high-pressure water dissolved wash, inverter drive motor, and ConnectLife IoT cloud diagnostics: Blocked coin filter, foreign object jamming impeller, kinked drain line, or open pump motor coil (~150–220 Ω).

Unscrew and clean bottom coin filter. Verify free impeller spin by hand. Measure drain pump winding resistance with multimeter (~150–220 Ω). Turn power off with Power button. Press and hold Start/Pause for 5 seconds to clear cycle memory. Power on and select new cycle.

Diagnose
E04
Dishwasher
Drainage System & Drain Pump

Hisense AutoDry / Smart Wash / PureClean Dishwasher: Base pan leak detection E04; polystyrene float switch in bottom drip tray activates emergency continuous drainage.

On Hisense dishwashers utilizing Dual-inverter circulation and drain pumps, AutoDry automatic door release, and 16 place settings flexible rack system: Leaking circulation pump shaft seal, cracked sump gasket, split spray arm joint, or loose hose clamp.

Unplug unit. Tilt machine backward 45° onto a towel to drain base pan. Inspect circulation pump volute and sump perimeter for chalky leak trails. Open door slightly, press and hold Programme and Start buttons for 4 seconds until the display shows '0:00', close door to drain.

Diagnose
E04
Tumble Dryer
NTC Temperature Sensor & Thermistor

Hisense Allergy Care / Heat Pump / ConnectLife Tumble Dryer: Process air NTC temperature sensor fault E04; machine aborts cycle after 2 minutes or overheats and triggers safety trip.

On Hisense dryers featuring Closed thermodynamic heat pump circuit, dual lint filtering screens, and anti-crease bidirectional drum tumbling: NTC sensor open circuit or shorted, wiring harness chaffed against chassis, or resistance drifting beyond curve (standard ~10–20 kΩ at 25°C).

Unplug NTC connector at main board. Measure sensor resistance with multimeter: expected ~10–20 kΩ at 25°C (~4–6 kΩ at 60°C). Replace sensor if out of spec. Rotate dial to Off. Press and hold Start/Pause and Anti-Crease buttons for 5 seconds until the acoustic chime sounds, then restart.

Diagnose
E04
Hob / Cooktop
NTC Temperature Sensor & Thermistor

Hisense Rapid Boil / ConnectLife / Smart Zone Induction Cooktop: Induction coil center temperature probe fault E04; zone display posts error and cuts heating to protect ceramic glass from cracking.

On Hisense cooktops with Smart Zone automatic pan detection, Rapid Boil power boost generator, and touch-slide individual zone controls: Spring-loaded center NTC probe open circuit or disconnected (~100 kΩ or ~10 kΩ at 25°C), or sensor silicone cap degraded.

Measure NTC probe resistance across its dual terminals: nominal ~100 kΩ (or ~10 kΩ depending on board version) at 25°C. Check spring contact against underside of glass. Wipe glass clean and dry. Switch off breaker on main board for 60 seconds, restore power and touch Child Lock sensor for 4 seconds.

Diagnose
E04
Oven / Microwave
Heating Element, Thermostat & Safety Fuse

Hisense Even Bake / Steam Add Plus / PureCook Built-in Oven: Cavity high-limit overtemperature emergency shutoff E04; thermal Klixon trips (>320°C bake / >500°C pyro) completely powering off heating elements.

On Hisense ovens with Even Bake rounded cavity design inspired by wood-fired ovens, Steam Add Plus injection, and Air Fry technology: Welded heating relay keeping element continuously energized, defective cavity sensor under-reading temperature, or jammed cooling airflow.

Allow oven to cool down completely. Reset Klixon if equipped with manual red pin on top casing. Test continuity (<0.5 Ω cold). Check PCB relays for welded contacts. Set function knob to 0. Cut off mains electricity at fuse board for 60 seconds, restore power and configure digital clock.

Diagnose
E04
Refrigerator / Freezer
Refrigeration Compressor, Defrost Heater & PTC Relay

Hisense PureFlat / Multi Air Flow / Total No Frost Refrigerator: Ambient room temperature sensor failure E04; dynamic defrost interval calculations and door heater logic misbehave.

On Hisense refrigeration units with PureFlat seamless flat-door design, Multi Air Flow columns, electronic dual-temperature zones, and inverter compressor: Open or shorted ambient NTC thermistor mounted on top hinge cover or behind display panel (~10 kΩ at 25°C).

Inspect ambient sensor under top hinge cap. Measure resistance at room temperature: expected ~10 kΩ at 25°C (~12.5 kΩ at 20°C). Replace sensor if value is open. Press and hold Super Cool and Super Freeze buttons simultaneously for 6 seconds until display flashes and clears fault code history.

Diagnose
E04
Washing Machine
Drainage System & Drain Pump

Hisense PureJet / AutoDosing / ConnectLife Series Washer: Anti-flood protection triggered E04; safety drain pump runs continuously and program halts due to water in base pan.

On Hisense washing machines utilizing PureJet high-pressure water dissolved wash, inverter drive motor, and ConnectLife IoT cloud diagnostics: Internal hydraulic hose split, tub seal degradation, dispenser overflow, or stuck polystyrene base float microswitch.

Disconnect mains power immediately. Tilt unit back 45° to drain base tray. Locate and seal internal hose leak. Test float switch continuity (<1 Ω). Turn power off with Power button. Press and hold Start/Pause for 5 seconds to clear cycle memory. Power on and select new cycle.

Diagnose
E4
Refrigerator / Freezer
Refrigeration Compressor, Defrost Heater & PTC Relay

Freezer defrost sensor fault. Diagnostic error code E4 reported on Hisense Refrigerator.

On Hisense Refrigerator: The defrost sensor in the freezer compartment has failed, which can lead to ice buildup.

On Hisense Refrigerator: The appliance will need to be serviced by a technician to replace the faulty sensor.

Diagnose
E05
Dishwasher
NTC Temperature Sensor & Thermistor

Hisense AutoDry / Smart Wash / PureClean Dishwasher: Temperature sensor communication anomaly E05; wash NTC circuit voltage drops to 0V (short) or rises to 5V (open circuit).

On Hisense dishwashers featuring Dual-inverter circulation and drain pumps, AutoDry automatic door release, and 16 place settings flexible rack system: Defective negative temperature coefficient thermistor bead, corroded plug terminals in sump, or broken harness lead.

Unplug NTC harness plug from sump. Measure resistance across sensor pins: ~10–12 kΩ at 25°C, ~2.5 kΩ at 60°C. Check wiring continuity to PCB. Open door slightly, press and hold Programme and Start buttons for 4 seconds until the display shows '0:00', close door to drain.

Diagnose
E05
Tumble Dryer
Drive Motor, Inverter & Tachometer Sensor

Hisense Allergy Care / Heat Pump / ConnectLife Tumble Dryer: Electronic moisture conductance sensor anomaly E05; program ends prematurely after 3 to 5 minutes with damp clothes inside.

On Hisense dryers with Closed thermodynamic heat pump circuit, dual lint filtering screens, and anti-crease bidirectional drum tumbling: Insulating scale or fabric softener film coating the dual stainless steel sensor bars, or worn drum ground slip brush.

Clean stainless sensor electrodes below door opening with white vinegar and fine abrasive pad. Check copper ground carbon brush on top/rear of drum (<2 Ω to earth). Rotate dial to Off. Press and hold Start/Pause and Anti-Crease buttons for 5 seconds until the acoustic chime sounds, then restart.

Diagnose
E05
Hob / Cooktop
Electronic Control Board (PCB) & Bus Communications

Hisense Rapid Boil / ConnectLife / Smart Zone Induction Cooktop: Mains supply voltage high overvoltage protection E05; cooktop beeps and isolates electronic components to prevent catastrophic failure.

On Hisense cooktops with Smart Zone automatic pan detection, Rapid Boil power boost generator, and touch-slide individual zone controls: AC input voltage exceeding 275V AC, accidental 400V connection between phase and neutral during installation, or severe line surge.

Immediately disconnect power! Check voltage between Phase (L) and Neutral (N): must be 230V AC (not 400V). Verify neutral jumper bridge on mains terminal block. Wipe glass clean and dry. Switch off breaker on main board for 60 seconds, restore power and touch Child Lock sensor for 4 seconds.

Diagnose
E05
Oven / Microwave
Heating Element, Thermostat & Safety Fuse

Hisense Even Bake / Steam Add Plus / PureCook Built-in Oven: Bottom sole heating element open circuit E05; bottom crust remains uncooked and lower chamber fails to reach set temperature.

On Hisense ovens with Even Bake rounded cavity design inspired by wood-fired ovens, Steam Add Plus injection, and Air Fry technology: Burned-out bottom heating element wire (~35–50 Ω nominal, 1200–1500W), burnt faston terminal connector, or defective wiring wire loom.

Disconnect power. Access rear or bottom panel. Measure resistance across bottom element terminals: expected ~35–50 Ω (infinite indicates open circuit). Replace element. Set function knob to 0. Cut off mains electricity at fuse board for 60 seconds, restore power and configure digital clock.

Diagnose
← Previous Page
Page 1 of 5 (144 results)Next Page →

Hisense — Complete Error Code Catalog

44 Verified Error Codes

Server-side index of all verified manufacturer error codes for technicians and automated crawlers.

Dishwasher25

E01E02E03E04E05E06E07E08E09E10E11E12E13E14E15F01F02F2F03F3F04F05F5F8F12

Washing Machine8

E18E19E20F06F07F13F24UNB

Tumble Dryer1

E16

Oven / Microwave5

E17F-1F-3F-4F-8

Refrigerator / Freezer5

E0E4E9F1H

Need Help? Call a Certified Technician

Our official certified partners service Hisense appliances in your area.

Electroassistance (Switzerland)Appliance Care UK (United Kingdom)
CodesErreur.com

Premium appliance diagnostics & repair database.
Powered by AI to help certified technicians worldwide.

Trusted by professionals in CH & FR

Platform

Search DatabasePRO Diagnostic AIPRODiagnostic ToolsBrands

Workshop Tools

Brands (87)OEM ManualsFind Rating PlateParts Locator

For Technicians

SpecialistsTechnician ForumTech JobsPremium

Corporate

Terms of ServicePrivacy PolicyOfficial Swiss Repair Partner: Electroassistance
OPERATIONAL SAFETY SPECIFICATION

SAFETY DISCLAIMER

The technical information, diagnostic guides, error codes, and AI-generated suggestions provided on this website are intended exclusively for certified and qualified professionals. Appliance repair involves severe electrical hazards, high voltages, and mechanical risks that can result in fatal injury or severe property damage. If you are not a trained technician, do not attempt to repair any appliances. CodesErreur assumes no responsibility or liability for any damage, injury, or consequential losses resulting from the use of the information provided on this platform. You use all information entirely at your own risk.

© 2026 CodesErreur. All rights reserved.

Official Swiss Repair Partner: Electroassistance Terms of Service Privacy Policy