Westinghouse EasyCare / Front Loader Washer Series: AquaStop / auxiliary drain circuit anomaly E25; safety drain relay or secondary drain sensing mismatch.
On Westinghouse (Westinghouse EasyCare / Front Loader Washer Series) models: Micro-switch contacts oxidized on base float sensor, auxiliary pump triac damaged, or logic mismatch in dual-drain system.
Inspect bottom drip tray for water and test float switch continuity (< 1 Ω closed). Check auxiliary relay contacts on main PCB. Press Start/Pause together with Temp button for 5 seconds to exit service diagnostic mode and clear persistent EEPROM alarm.