Westinghouse
Westinghouse // OFFICIAL DIAGNOSTIC BENCH

Westinghouse F105

OvenNTC Temperature Sensor & Thermistor
Integrated luxury convection oven and induction cooktop with illuminated touch controls
Oven
Other Brands Sharing Code F105:MieleF105ElectroluxF105AEGF105ZanussiF105Arthur MartinF105CastorF105FaureF105FrigidaireF105KelvinatorF105ZoppasF105

Symptom / Description

FAULT

Westinghouse Elevate / Multi-Function Built-in Oven: Food meat probe circuit error F105; internal temperature sensing probe jack shorted, open, or reading abnormal resistance.

TELEMETRY // LIVESIG: FAULT_DETECTED

Root Cause

ROOT CAUSE

On Westinghouse (Westinghouse Elevate / Multi-Function Built-in Oven) models: Grease or moisture penetration inside probe cavity jack, damaged silicone cable on meat probe needle, or open PT1000 sensor inside probe tip (~1079 Ω at 20°C).

CIRCUIT // SUBSYSTEMLOGIC: ROOT_ISOLATED

Repair Instructions

UNLOCKED
1Unplug meat probe from cavity socket. Clean socket contacts with isopropyl alcohol. Measure probe resistance across plug pins with multimeter (~1079 Ω at 20°C). Press Start/Pause together with Temp button for 5 seconds to exit service diagnostic mode and clear persistent EEPROM alarm.
AI diagnostic workshop engine analyzing appliance circuit schematics and error telemetry in real time
AI WORKSHOP PROTOCOL ENGINE
Direct extraction from OEM factory manuals & wiring schematics

Field Actions

DISPATCH
Need Help? Call a Certified TechnicianWorldwide Westinghouse Parts Finder
Electrical & Safety Protocol

Always disconnect appliance from 230V/400V mains before opening panels. Use CAT III multimeter for circuit testing.

CALIBRATED BENCH PROTOCOL // CAT III 600V

Workshop Verification & Safety Checklist

WORKSHOP VERIFICATION PROTOCOLNTC Temperature Sensor & ThermistorOven / Microwave
2. Multimeter & Electrical Bench Tests (Ω)
MODE: OHMMETER (Ω)AUTO-RANGE
Precision digital multimeter probes measuring electrical resistance in Ohms on an appliance control board
CALIBRATED METROLOGY RESISTANCE BENCH (CAT III)
Nominal Resistance (Ω)
4.8kΩ–12kΩ (at 20°C–25°C)NOMINAL
0 Ω (SHORT)CALIBRATED BAND∞ OL (OPEN)
▲ NOMINAL OPERATING WINDOW
Target Component:NTC Temperature Sensor Probe (Thermistor)
Test Pins & Connections
PROBE (+)
PROBE (-)
Across sensor pins 1-2 (unplugged harness)
Tolerance & Diagnostic CriteriaNegative temperature coefficient: resistance drops smoothly when warmed with fingers. OL = open circuit.
1. Pre-Intervention Electrical Safety Protocols
  • !Electrical Safety Protocol: Disconnect 230V electrical mains power before removing appliance side or rear panels.
  • !Ensure tub water or heating chamber has cooled below 30°C before unclipping thermistor probe.
  • !Use CAT III 600V/1000V insulated test probes when tng at PCB edge connectors.
3. Preliminary Mechanical & Visual Checks
  • Inspect sensor immersion sleeve for calcification, limescale scale, or thermal paste degradation.
  • Check wiring harness for pinch points, chafing against chassis metal, and terminal pin oxidation.
  • Verify probe is firmly seated in its rubber grommet or bracket inside the water/air circuit.
Perform these diagnostic steps before triggering AI Deep Search or replacing boards.Certified Workshop Routine

Frequently Asked Questions: Westinghouse F105

FAQ TREE
What does error code F105 mean on a Westinghouse appliance?

Westinghouse error code F105 indicates: Westinghouse Elevate / Multi-Function Built-in Oven: Food meat probe circuit error F105; internal temperature sensing probe jack shorted, open, or reading abnormal resistance..

What is the root cause of Westinghouse error code F105?

The primary root cause for Westinghouse code F105 is: On Westinghouse (Westinghouse Elevate / Multi-Function Built-in Oven) models: Grease or moisture penetration inside probe cavity jack, damaged silicone cable on meat probe needle, or open PT1000 sensor inside probe tip (~1079 Ω at 20°C)..

How do I fix or resolve Westinghouse error code F105?

To resolve error code F105: Unplug meat probe from cavity socket. Clean socket contacts with isopropyl alcohol. Measure probe resistance across plug pins with multimeter (~1079 Ω at 20°C). Press Start/Pause together with Temp button for 5 seconds to exit service diagnostic mode and clear persistent EEPROM alarm.

Is it safe to clear Westinghouse error code F105 by resetting power?

Resetting power (unplugging for 5–10 minutes) clears temporary memory errors. However, if Westinghouse code F105 persists, the physical component causing On Westinghouse (Westinghouse Elevate / Multi-Function Built-in Oven) models: Grease or moisture penetration inside probe cavity jack, damaged silicone cable on meat probe needle, or open PT1000 sensor inside probe tip (~1079 Ω at 20°C). must be inspected or replaced.

How do I test electrical resistance for Westinghouse code F105 using a multimeter?

Set a digital multimeter to ohms (Ω). Disconnect power and test NTC Temperature Sensor Probe (Thermistor) across Across sensor pins 1-2 (unplugged harness). Expected nominal reading is 4.8kΩ–12kΩ (at 20°C–25°C). Tolerance: Negative temperature coefficient: resistance drops smoothly when warmed with fingers. OL = open circuit..

What safety protocol must be followed before servicing Westinghouse code F105?

Standard electrical safety protocol: 1. Disconnect 230V mains power before opening panels. 2. Verify zero voltage at test points. 3. Allow hot water or heating elements to cool below 30°C before handling.

Community Verification

COMMUNITY

Did this solution resolve the issue?

SEMANTIC KNOWLEDGE GRAPH // WESTINGHOUSE

Related Westinghouse Oven / Microwave Error Codes

Diagnostic Link Mesh14 OEM Cross-References

Cross-referenced diagnostic codes for technicians inspecting similar component subsystems.

F106Heating Element, Thermostat & Safety Fuse
Westinghouse Elevate / Multi-Function Built-in Oven: Heating safety relay welded F106; main ...
Inspect Protocol
F107Electronic Control Board (PCB) & Bus Communications
Westinghouse Elevate / Multi-Function Built-in Oven: Internal communication link error F107;...
Inspect Protocol
F108Heating Element, Thermostat & Safety Fuse
Westinghouse Elevate / Multi-Function Built-in Oven: Electrical mains frequency error F108; ...
Inspect Protocol
F109NTC Temperature Sensor & Thermistor
Westinghouse Elevate / Multi-Function Built-in Oven: Cavity temperature sensor fault F109; e...
Inspect Protocol
F110Drive Motor, Inverter & Tachometer Sensor
Westinghouse Elevate / Multi-Function Built-in Oven: Door lock position mismatch F110; micro...
Inspect Protocol
F111Heating Element, Thermostat & Safety Fuse
Westinghouse Elevate / Multi-Function Built-in Oven: Heating rise timeout F111; oven tempera...
Inspect Protocol
F112Electronic Control Board (PCB) & Bus Communications
Westinghouse Elevate / Multi-Function Built-in Oven: Appliance EEPROM configuration error F1...
Inspect Protocol
F101Drive Motor, Inverter & Tachometer Sensor
Westinghouse Elevate / Multi-Function Built-in Oven: Door lock motorized latch error F101; o...
Inspect Protocol
F102Drive Motor, Inverter & Tachometer Sensor
Westinghouse Elevate / Multi-Function Built-in Oven: Door unlock timeout F102; pyrolytic lat...
Inspect Protocol
F103Drive Motor, Inverter & Tachometer Sensor
Westinghouse Elevate / Multi-Function Built-in Oven: Tangential cooling fan speed error F103...
Inspect Protocol
F104Electronic Control Board (PCB) & Bus Communications
Westinghouse Elevate / Multi-Function Built-in Oven: Electronic control board over-temperatu...
Inspect Protocol
E0Electronic Control Board (PCB) & Bus Communications
Westinghouse WHI Series / Induction Cooktop: Electronic sub-bus communication error E0; comm...
Inspect Protocol
E1Water Level Pressure Switch & Air Dome
Westinghouse WHI Series / Induction Cooktop: Touch control surface blocked E1; continuous to...
Inspect Protocol
E2NTC Temperature Sensor & Thermistor
Westinghouse WHI Series / Induction Cooktop: Induction coil overheating alarm E2; induction ...
Inspect Protocol
CodesErreur.com

Premium appliance diagnostics & repair database.
Powered by AI to help certified technicians worldwide.

Trusted by professionals in CH & FR

Platform

Search DatabasePRO Diagnostic AIPRODiagnostic ToolsBrands

Workshop Tools

Brands (87)OEM ManualsFind Rating PlateParts Locator

For Technicians

SpecialistsTechnician ForumTech JobsPremium

Corporate

Terms of ServicePrivacy PolicyOfficial Swiss Repair Partner: Electroassistance
OPERATIONAL SAFETY SPECIFICATION

SAFETY DISCLAIMER

The technical information, diagnostic guides, error codes, and AI-generated suggestions provided on this website are intended exclusively for certified and qualified professionals. Appliance repair involves severe electrical hazards, high voltages, and mechanical risks that can result in fatal injury or severe property damage. If you are not a trained technician, do not attempt to repair any appliances. CodesErreur assumes no responsibility or liability for any damage, injury, or consequential losses resulting from the use of the information provided on this platform. You use all information entirely at your own risk.

© 2026 CodesErreur. All rights reserved.

Official Swiss Repair Partner: Electroassistance Terms of Service Privacy Policy