Field Actions
DISPATCHAlways disconnect appliance from 230V/400V mains before opening panels. Use CAT III multimeter for circuit testing.
Frequently Asked Questions: Faure F105
FAQ TREEWhat does error code F105 mean on a Faure appliance?
Faure error code F105 indicates: Faure FCI / FOP Series / Pyrolyse Confort Oven: Food meat probe circuit error F105; internal temperature sensing probe jack shorted, open, or reading abnormal resistance..
What is the root cause of Faure error code F105?
The primary root cause for Faure code F105 is: On Faure (Faure FCI / FOP Series / Pyrolyse Confort Oven) models: Grease or moisture penetration inside probe cavity jack, damaged silicone cable on meat probe needle, or open PT1000 sensor inside probe tip (~1079 Ω at 20°C)..
How do I fix or resolve Faure error code F105?
To resolve error code F105: Unplug meat probe from cavity socket. Clean socket contacts with isopropyl alcohol. Measure probe resistance across plug pins with multimeter (~1079 Ω at 20°C). Press and hold Départ/Pause and Annulation buttons for 6 seconds until all status indicators flash synchronously and clear fault memory.
Is it safe to clear Faure error code F105 by resetting power?
Resetting power (unplugging for 5–10 minutes) clears temporary memory errors. However, if Faure code F105 persists, the physical component causing On Faure (Faure FCI / FOP Series / Pyrolyse Confort Oven) models: Grease or moisture penetration inside probe cavity jack, damaged silicone cable on meat probe needle, or open PT1000 sensor inside probe tip (~1079 Ω at 20°C). must be inspected or replaced.
How do I test electrical resistance for Faure code F105 using a multimeter?
Set a digital multimeter to ohms (Ω). Disconnect power and test NTC Temperature Sensor Probe (Thermistor) across Across sensor pins 1-2 (unplugged harness). Expected nominal reading is 4.8kΩ–12kΩ (at 20°C–25°C). Tolerance: Negative temperature coefficient: resistance drops smoothly when warmed with fingers. OL = open circuit..
What safety protocol must be followed before servicing Faure code F105?
Standard electrical safety protocol: 1. Disconnect 230V mains power before opening panels. 2. Verify zero voltage at test points. 3. Allow hot water or heating elements to cool below 30°C before handling.
Community Verification
COMMUNITYDid this solution resolve the issue?



