Skip to content
CodesErreur.comSWISS PRO ENGINE
Core Diagnostics
DiagnosticsBrandsOEM ManualsSpecialistsAI EngineerPRO
Workshop Tools
Diagnostic ToolsNEW
Hardware interfaces & test probes
Find Rating Plate
Locate exact E-Nr, PNC & serial codes
Parts Locator
Global OEM spare parts suppliers
Community & Career
Academy & Courses
Masterclasses by senior technicians
Certification ExamsPRO
Verify your B2B technical credentials
Elite Forum
Peer-to-peer field troubleshooting
Tech Jobs
B2B recruitment & field opportunities
Leaderboard
Global ranking of verified specialists
Certified Appliance Engineering EcosystemApply for Certification →
Language Selector
Account & Access
Upgrade PRO
Back to Search
Zoppas • Central Diagnostic Dictionary
191 Verified Codes in Database

Zoppas Error Codes & Diagnostics

Access our premium database of error codes, common faults, and professional repair solutions for Zoppas appliances.

Luxury front-loading washing machine in brushed titanium with illuminated dark glass drum
CodeAppliancesFault / DiagnosticsRepair InstructionsAction
EF2
Washing Machine
General System & Mechanical Integration

Zoppas PWF Series / Armonia Elettronica Washer: Detergent overdosing / excessive foam warning EF2; foam layer prevents drum spin acceleration.

On Zoppas (Zoppas PWF Series / Armonia Elettronica Washer) models: Too much high-sudsing detergent used, hand-washing detergent accidentally added, or low water hardness requiring reduced dosage.

Cancel cycle and run cold rinse programme without detergent. Reduce powder or liquid detergent dosage in future wash loads. Hold Avvio/Pausa and Annulla simultaneously for 5 seconds until the acoustic triple beep confirms memory clearing.

Diagnose
EF3
Washing Machine
Drainage System & Drain Pump

Zoppas PWF Series / Armonia Elettronica Washer: AquaControl anti-flood protection active EF3; float switch triggered in base pan with continuous safety drain.

On Zoppas (Zoppas PWF Series / Armonia Elettronica Washer) models: Water leak from tub hose, split door bellow gasket, leaking water inlet valve, or drain pump housing crack accumulating water in base.

Disconnect power and shut water tap. Tilt machine backward 45° to drain base tray onto towels. Locate leak source and replace leaking component. Hold Avvio/Pausa and Annulla simultaneously for 5 seconds until the acoustic triple beep confirms memory clearing.

Diagnose
EF4
Washing Machine
Water Inlet Valve, Aquastop & Flowmeter

Zoppas PWF Series / Armonia Elettronica Washer: Low water inlet pressure warning EF4; flowmeter pulses detected but intake flow rate is below 5 L/min.

On Zoppas (Zoppas PWF Series / Armonia Elettronica Washer) models: Partially closed water supply tap, encrusted limescale in flowmeter impeller, clogged inlet hose mesh, or low municipal water pressure.

Open household water tap fully. Unscrew inlet hose and clean mesh filter under running water. Verify flow rate of at least 8 L/min into bucket. Hold Avvio/Pausa and Annulla simultaneously for 5 seconds until the acoustic triple beep confirms memory clearing.

Diagnose
EF5
Washing Machine
General System & Mechanical Integration

Zoppas PWF Series / Armonia Elettronica Washer: Unbalanced load spin abort warning EF5; high drum eccentricity prevents safe spin acceleration.

On Zoppas (Zoppas PWF Series / Armonia Elettronica Washer) models: Single heavy item (bath mat, heavy towel, bathrobe) washed alone, balled-up duvet cover trapping smaller clothes, or worn shock absorbers.

Pause machine, open door, and redistribute laundry evenly around drum perimeter. Add two medium towels to balance single heavy items. Hold Avvio/Pausa and Annulla simultaneously for 5 seconds until the acoustic triple beep confirms memory clearing.

Diagnose
EH0
Tumble Dryer
General System & Mechanical Integration

Zoppas PTE Series / Asciuga Facile Condenser Dryer: Electrical mains supply out of limits EH0; appliance pauses cycle to protect electronic components from electrical instability.

On Zoppas (Zoppas PTE Series / Asciuga Facile Condenser Dryer) models: Mains voltage dropped below 185V AC or surged above 265V AC, mains frequency unstable (outside 50Hz/60Hz ±1Hz), or loose neutral connection at wall socket.

Measure line-to-neutral AC voltage with true-RMS multimeter (expected 220–240V AC). Inspect wall socket connections and check for shared extension cords. Hold Avvio/Pausa and Annulla simultaneously for 5 seconds until the acoustic triple beep confirms memory clearing.

Diagnose
EH0
Washing Machine
Electronic Control Board (PCB) & Bus Communications

Zoppas PWF Series / Armonia Elettronica Washer: Mains power supply out of specification alarm EH0; generic electrical supply anomaly detected.

On Zoppas (Zoppas PWF Series / Armonia Elettronica Washer) models: Combined voltage and frequency anomaly, defective zero-crossing detector on main PCB, or burned connections at terminal block.

Inspect mains terminal block behind machine for melted plastic. Check 230V AC supply stability and clean EMI line filter connections. Hold Avvio/Pausa and Annulla simultaneously for 5 seconds until the acoustic triple beep confirms memory clearing.

Diagnose
EH1
Washing Machine
Drive Motor, Inverter & Tachometer Sensor

Zoppas PWF Series / Armonia Elettronica Washer: Mains electrical frequency out of range EH1; frequency is outside the 43 Hz to 67 Hz window.

On Zoppas (Zoppas PWF Series / Armonia Elettronica Washer) models: Operation on uncalibrated portable generator or off-grid solar inverter, severe electrical grid harmonic distortion, or failing PCB timer clock.

Measure electrical frequency with multimeter frequency mode (must be 50.0 Hz ± 0.5 Hz). Avoid operating machine from non-sinusoidal generators. Hold Avvio/Pausa and Annulla simultaneously for 5 seconds until the acoustic triple beep confirms memory clearing.

Diagnose
EH2
Washing Machine
General System & Mechanical Integration

Zoppas PWF Series / Armonia Elettronica Washer: Mains supply overvoltage alarm EH2; mains electrical supply exceeds 275V RMS.

On Zoppas (Zoppas PWF Series / Armonia Elettronica Washer) models: Lightning strike on local grid, loss of neutral in three-phase building distribution causing 400V phase shift, or transient power surges.

Unplug washing machine immediately to prevent board destruction. Have an electrician test mains voltage (must not exceed 253V AC maximum). Hold Avvio/Pausa and Annulla simultaneously for 5 seconds until the acoustic triple beep confirms memory clearing.

Diagnose
EH3
Washing Machine
General System & Mechanical Integration

Zoppas PWF Series / Armonia Elettronica Washer: Mains supply undervoltage alarm EH3; electrical supply voltage drops below 175V RMS.

On Zoppas (Zoppas PWF Series / Armonia Elettronica Washer) models: Heavy electrical overload on home circuits, degraded service drop lines from utility company, or resistive connection in wall outlet.

Measure voltage at wall outlet during wash cycle startup. If below 200V AC, contact electrical utility or inspect home circuit breaker. Hold Avvio/Pausa and Annulla simultaneously for 5 seconds until the acoustic triple beep confirms memory clearing.

Diagnose
F
Hob / Cooktop
General System & Mechanical Integration

Zoppas PIE Series / Piano a Induzione Cooktop: Pan detection symbol F flashing; cooking zone cannot detect magnetic cookware or pan diameter is too small.

On Zoppas (Zoppas PIE Series / Piano a Induzione Cooktop) models: Cookware made of non-ferrous material (copper, glass, pure aluminium), pan base deformed and lifted away from glass, or pan placed off-center.

Test base of cookware with permanent magnet (must attract firmly). Ensure cookware base covers at least 70% of zone cross-hairs markings. Hold Avvio/Pausa and Annulla simultaneously for 5 seconds until the acoustic triple beep confirms memory clearing.

Diagnose
F1
Refrigerator / Freezer
NTC Temperature Sensor & Thermistor

Zoppas PRB Series / Clima System Refrigerator-Freezer: Fresh food compartment air sensor failure F1; refrigerator compartment temperature regulation becomes erratic.

On Zoppas (Zoppas PRB Series / Clima System Refrigerator-Freezer) models: Refrigerator compartment NTC thermistor open or short circuit (~2.5 kΩ or ~5.0 kΩ at 25°C depending on platform), or moisture on sensor connector.

Locate air sensor inside fresh food compartment. Measure resistance with multimeter (typically ~2.5 kΩ at 25°C, rising to ~5.9 kΩ at 4°C). Hold Avvio/Pausa and Annulla simultaneously for 5 seconds until the acoustic triple beep confirms memory clearing.

Diagnose
F2
Refrigerator / Freezer
Refrigeration Compressor, Defrost Heater & PTC Relay

Zoppas PRB Series / Clima System Refrigerator-Freezer: Evaporator coil sensor failure F2; automatic defrost termination monitoring fails, risking ice accumulation on coil.

On Zoppas (Zoppas PRB Series / Clima System Refrigerator-Freezer) models: Evaporator clip-on NTC probe defective or dislodged from refrigerant return bend, water ingress freezing inside probe sleeve, or open wire.

Remove rear freezer panel. Test evaporator NTC resistance (typically ~2.5 kΩ at 25°C, rising to ~16.3 kΩ at -18°C). Clip firmly to copper return pipe. Hold Avvio/Pausa and Annulla simultaneously for 5 seconds until the acoustic triple beep confirms memory clearing.

Diagnose
F3
Refrigerator / Freezer
NTC Temperature Sensor & Thermistor

Zoppas PRB Series / Clima System Refrigerator-Freezer: Ambient room temperature sensor error F3; external climate class compensation calculation disabled.

On Zoppas (Zoppas PRB Series / Clima System Refrigerator-Freezer) models: Ambient NTC thermistor inside top hinge cover or display module open/shorted, or severed wire pinched by refrigerator door upper hinge.

Remove top hinge plastic cover. Inspect ambient NTC sensor and harness. Measure resistance (~2.5 kΩ or ~5.0 kΩ at 25°C room temperature). Hold Avvio/Pausa and Annulla simultaneously for 5 seconds until the acoustic triple beep confirms memory clearing.

Diagnose
F4
Refrigerator / Freezer
NTC Temperature Sensor & Thermistor

Zoppas PRB Series / Clima System Refrigerator-Freezer: Freezer compartment temperature sensor failure F4; freezer cooling runs in continuous emergency backup mode.

On Zoppas (Zoppas PRB Series / Clima System Refrigerator-Freezer) models: Freezer air NTC sensor open circuit or damaged by frozen condensation, broken wire behind freezer inner liner, or corrupted ADC input on motherboard.

Access freezer air sensor probe. Test resistance with ohmmeter: ~2.5 kΩ at 25°C, increasing to ~16.3 kΩ at -18°C. Replace sensor probe if out of spec. Hold Avvio/Pausa and Annulla simultaneously for 5 seconds until the acoustic triple beep confirms memory clearing.

Diagnose
F5
Refrigerator / Freezer
Refrigeration Compressor, Defrost Heater & PTC Relay

Zoppas PRB Series / Clima System Refrigerator-Freezer: Defrost heater circuit failure F5; electric defrost heater fails to energize, causing frost to clog evaporator fins.

On Zoppas (Zoppas PRB Series / Clima System Refrigerator-Freezer) models: Open glass calrod/metal defrost heating element (nominal 200–350W, ~150–260 Ω), blown thermal fuse in series (72°C or 77°C), or burnt defrost relay on PCB.

Access bottom of evaporator. Disconnect defrost element and measure resistance (~150–260 Ω). Test thermal fuse continuity with ohmmeter (< 0.5 Ω). Hold Avvio/Pausa and Annulla simultaneously for 5 seconds until the acoustic triple beep confirms memory clearing.

Diagnose
F6
Refrigerator / Freezer
Refrigeration Compressor, Defrost Heater & PTC Relay

Zoppas PRB Series / Clima System Refrigerator-Freezer: Inverter compressor driver fault F6; BLDC compressor fails to start or inverter trips due to over-current.

On Zoppas (Zoppas PRB Series / Clima System Refrigerator-Freezer) models: Seized compressor piston mechanism, open winding in 3-phase BLDC stator (~6–15 Ω between all terminal pairs), or blown power transistors on inverter board.

Measure resistance across all 3 compressor pins with ohmmeter (must be equal: ~6–15 Ω). Measure PWM frequency signal from main PCB to inverter board. Hold Avvio/Pausa and Annulla simultaneously for 5 seconds until the acoustic triple beep confirms memory clearing.

Diagnose
F7
Refrigerator / Freezer
Refrigeration Compressor, Defrost Heater & PTC Relay

Zoppas PRB Series / Clima System Refrigerator-Freezer: Evaporator fan motor malfunction F7; fan motor blocked by ice or hall feedback pulse missing, starving airflow.

On Zoppas (Zoppas PRB Series / Clima System Refrigerator-Freezer) models: Ice accumulation freezing the fan blades, defective 12V DC brushless motor windings, severed connector lead, or blown fan driver IC on main motherboard.

Manually spin fan blade to check for ice obstruction. Measure 12V DC supply to fan terminals with multimeter during test mode. Replace fan if seized. Hold Avvio/Pausa and Annulla simultaneously for 5 seconds until the acoustic triple beep confirms memory clearing.

Diagnose
F101
Oven / Microwave
Drive Motor, Inverter & Tachometer Sensor

Zoppas POB Series / Forno Ventilato Built-in Oven: Door lock motorized latch error F101; oven door fails to lock automatically during pyrolytic cleaning initiation.

On Zoppas (Zoppas POB Series / Forno Ventilato Built-in Oven) models: Defective door lock synchronous gear motor (coil resistance ~2.0–2.8 kΩ), stuck cam mechanism, broken microswitch contact, or warped door hinge preventing flush seal.

Disconnect oven from mains. Access top latch assembly. Measure lock motor coil resistance (2.0–2.8 kΩ). Verify microswitch continuity with door closed (< 1 Ω). Hold Avvio/Pausa and Annulla simultaneously for 5 seconds until the acoustic triple beep confirms memory clearing.

Diagnose
F102
Oven / Microwave
Drive Motor, Inverter & Tachometer Sensor

Zoppas POB Series / Forno Ventilato Built-in Oven: Door unlock timeout F102; pyrolytic latch remains engaged even after cavity temperature drops below safe threshold (300°C).

On Zoppas (Zoppas POB Series / Forno Ventilato Built-in Oven) models: Latching cam stuck in locked position, burnt triac on motherboard driving lock motor, or misaligned unlock feedback microswitch.

Check for mechanical jamming in linkage. Test microswitch 2 (normally open, switches to < 1 Ω when unlocked). Verify 230V drive pulse from control board. Hold Avvio/Pausa and Annulla simultaneously for 5 seconds until the acoustic triple beep confirms memory clearing.

Diagnose
F103
Oven / Microwave
Drive Motor, Inverter & Tachometer Sensor

Zoppas POB Series / Forno Ventilato Built-in Oven: Tangential cooling fan speed error F103; cooling blower fails to rotate or tacho pulse frequency is too low.

On Zoppas (Zoppas POB Series / Forno Ventilato Built-in Oven) models: Tangential fan motor winding open (nominal 150–220 Ω), foreign debris stopping blower blades, loose hall effect sensor connector, or blown fan triac.

Isolate oven from power and inspect fan blades for free rotation. Measure motor winding resistance (150–220 Ω). Verify 5V DC supply to hall sensor. Hold Avvio/Pausa and Annulla simultaneously for 5 seconds until the acoustic triple beep confirms memory clearing.

Diagnose
F104
Oven / Microwave
Electronic Control Board (PCB) & Bus Communications

Zoppas POB Series / Forno Ventilato Built-in Oven: Electronic control board over-temperature F104; thermal sensor on main PCB measures excessive temperature (> 85°C).

On Zoppas (Zoppas POB Series / Forno Ventilato Built-in Oven) models: Cooling fan failure during extended high-temperature bake or pyrolytic cycle, blocked top ventilation slits in cabinet, or deteriorated cavity insulation.

Check kitchen installation clearances (minimum 50mm rear air gap). Ensure cabinet vents are clear of obstructions. Verify cooling blower operation. Hold Avvio/Pausa and Annulla simultaneously for 5 seconds until the acoustic triple beep confirms memory clearing.

Diagnose
F105
Oven / Microwave
NTC Temperature Sensor & Thermistor

Zoppas POB Series / Forno Ventilato Built-in Oven: Food meat probe circuit error F105; internal temperature sensing probe jack shorted, open, or reading abnormal resistance.

On Zoppas (Zoppas POB Series / Forno Ventilato Built-in Oven) models: Grease or moisture penetration inside probe cavity jack, damaged silicone cable on meat probe needle, or open PT1000 sensor inside probe tip (~1079 Ω at 20°C).

Unplug meat probe from cavity socket. Clean socket contacts with isopropyl alcohol. Measure probe resistance across plug pins with multimeter (~1079 Ω at 20°C). Hold Avvio/Pausa and Annulla simultaneously for 5 seconds until the acoustic triple beep confirms memory clearing.

Diagnose
F106
Oven / Microwave
Heating Element, Thermostat & Safety Fuse

Zoppas POB Series / Forno Ventilato Built-in Oven: Heating safety relay welded F106; main PCB detects continuity through heating element relay contacts when deactivated.

On Zoppas (Zoppas POB Series / Forno Ventilato Built-in Oven) models: Electrical arcing welded the 16A relay contacts on the power PCB, or transient voltage spike degraded the relay coil switching driver.

Disconnect oven mains immediately. Inspect relay contacts on power PCB with ohmmeter (must read ∞ Ω open circuit when unpowered). Replace PCB or relay. Hold Avvio/Pausa and Annulla simultaneously for 5 seconds until the acoustic triple beep confirms memory clearing.

Diagnose
F107
Oven / Microwave
Electronic Control Board (PCB) & Bus Communications

Zoppas POB Series / Forno Ventilato Built-in Oven: Internal communication link error F107; display module loses serial data exchange with the main power control board.

On Zoppas (Zoppas POB Series / Forno Ventilato Built-in Oven) models: Oxidized or unlatched edge connectors on multi-core ribbon cable, loss of 12V DC power bus supply, or firmware transmission parity errors.

Inspect connecting ribbon cable between UI display and power PCB. Re-seat connectors and check continuity (< 1 Ω). Verify 12V DC and 5V DC voltages. Hold Avvio/Pausa and Annulla simultaneously for 5 seconds until the acoustic triple beep confirms memory clearing.

Diagnose
F108
Oven / Microwave
Heating Element, Thermostat & Safety Fuse

Zoppas POB Series / Forno Ventilato Built-in Oven: Electrical mains frequency error F108; the clock oscillator detects power line frequency outside 50Hz / 60Hz limits.

On Zoppas (Zoppas POB Series / Forno Ventilato Built-in Oven) models: Emergency backup generator supply with dirty sine wave, extreme voltage harmonic distortion from heavy loads, or zero-cross detection resistor damaged on PCB.

Measure line frequency with digital multimeter (must be steady 50.0 Hz or 60.0 Hz ±0.5 Hz). Ensure oven is connected to pure utility grid supply. Hold Avvio/Pausa and Annulla simultaneously for 5 seconds until the acoustic triple beep confirms memory clearing.

Diagnose
F109
Oven / Microwave
NTC Temperature Sensor & Thermistor

Zoppas POB Series / Forno Ventilato Built-in Oven: Cavity temperature sensor fault F109; electronic board detects open circuit or shorted PT500 / PT1000 temperature sensor.

On Zoppas (Zoppas POB Series / Forno Ventilato Built-in Oven) models: Open platinum thermal sensor element in oven back wall (nominal ~540 Ω for PT500 or ~1080 Ω for PT1000 at 20°C), broken wiring lead, or pinched heat-resistant cable.

Disconnect oven mains. Access rear panel cavity sensor harness. Measure resistance with multimeter (PT500 reads ~540 Ω at 20°C; PT1000 reads ~1080 Ω at 20°C). Hold Avvio/Pausa and Annulla simultaneously for 5 seconds until the acoustic triple beep confirms memory clearing.

Diagnose
F110
Oven / Microwave
Drive Motor, Inverter & Tachometer Sensor

Zoppas POB Series / Forno Ventilato Built-in Oven: Door lock position mismatch F110; microswitch sensing signals conflict with commanded lock motor position.

On Zoppas (Zoppas POB Series / Forno Ventilato Built-in Oven) models: Bent microswitch operating arm on lock assembly, cracked cam profile, or loose harness wires swapping position 1 and position 2 feedback lines.

Inspect door lock assembly on top frame. Manually actuate lock cam to verify microswitch contacts toggle cleanly between 0 Ω and ∞ Ω. Hold Avvio/Pausa and Annulla simultaneously for 5 seconds until the acoustic triple beep confirms memory clearing.

Diagnose
F111
Oven / Microwave
Heating Element, Thermostat & Safety Fuse

Zoppas POB Series / Forno Ventilato Built-in Oven: Heating rise timeout F111; oven temperature fails to increase by at least 15°C within 15 minutes of heating initiation.

On Zoppas (Zoppas POB Series / Forno Ventilato Built-in Oven) models: Open circular fan-forced heating element (~28–32 Ω, ~2000W), open bottom heating element (~40–48 Ω, ~1000W), tripped manual Klixon safety stat, or open relay coil.

Disconnect oven power and remove rear access shield. Measure resistance of circular (~30 Ω), top grill (~22 Ω), and bottom (~44 Ω) heating elements. Hold Avvio/Pausa and Annulla simultaneously for 5 seconds until the acoustic triple beep confirms memory clearing.

Diagnose
F112
Oven / Microwave
Electronic Control Board (PCB) & Bus Communications

Zoppas POB Series / Forno Ventilato Built-in Oven: Appliance EEPROM configuration error F112; non-volatile memory parameters corrupted or unconfigured replacement module.

On Zoppas (Zoppas POB Series / Forno Ventilato Built-in Oven) models: Power failure or voltage spike during program write cycle, aged memory chip corruption, or blank spare control board installed without PNC coding.

Power cycle oven for 10 minutes. If error persists, enter diagnostic technician menu and re-program configuration code matching model PNC on rating plate. Hold Avvio/Pausa and Annulla simultaneously for 5 seconds until the acoustic triple beep confirms memory clearing.

Diagnose
i5A
Dishwasher
Drive Motor, Inverter & Tachometer Sensor

Zoppas PDF Series / Cristallo / Sanix Dishwasher: Circulation pump inverter heat sink thermal threshold reached i5A; power module de-rates or shuts down.

On Zoppas (Zoppas PDF Series / Cristallo / Sanix Dishwasher) models: Restricted airflow in bottom machinery compartment, sound deadening felt blanket shifted over inverter board, or high ambient heat.

Reposition sound insulation felt to ensure clear airflow channels around inverter heatsink. Clear dust from bottom chassis louvers. Hold Avvio/Pausa and Annulla simultaneously for 5 seconds until the acoustic triple beep confirms memory clearing.

Diagnose
← Previous PagePage 5 of 7 (191 results)Next Page →

Zoppas — Complete Error Code Catalog

167 Verified Error Codes

Server-side index of all verified manufacturer error codes for technicians and automated crawlers.

Dishwasher45

AL5AL6C1C2C3i5Ai5Bi5Ci5Di5Ei5Fi10i11i20i22i23i24i30i40i41i43i44i50i51i52i53i54i55i56i57i58i59i60i61i63i64i70i80i90iA0iB0iC0iD0iF0iF1

Washing Machine57

C9CFE3AE5AE5CE5DE5EE5FE5HE6HE9CE9EE10E11E12E13E20E21E22E23E24E25E33E34E35E38E40E41E42E43E44E45E66E68E69E74E82E83E84E85E94E95E97E98EA0EA1EA6EB0EF0EF1EF2EF3EF4EF5EH1EH2EH3

Tumble Dryer25

E30E31E32E50E51E52E53E54E57E58E59E60E61E62E63E70E71E72E73E80E90E91E92E93EH0

Oven / Microwave12

F101F102F103F104F105F106F107F108F109F110F111F112

Hob / Cooktop12

E0E1E2E3E4E5E6E7E8E9EAF

Refrigerator / Freezer16

E01E02E03E04E05E06E07F1F2F3F4F5F6F7SY EF5Y EF

Need Help? Call a Certified Technician

Our official certified partners service Zoppas appliances in your area.

Electroassistance (Switzerland)Appliance Care UK (United Kingdom)
CodesErreur.com

Premium appliance diagnostics & repair database.
Powered by AI to help certified technicians worldwide.

Trusted by professionals in CH & FR

Platform

Search DatabasePRO Diagnostic AIPRODiagnostic ToolsBrands

Workshop Tools

Brands (87)OEM ManualsFind Rating PlateParts Locator

For Technicians

SpecialistsTechnician ForumTech JobsPremium

Corporate

Terms of ServicePrivacy PolicyOfficial Swiss Repair Partner: Electroassistance
OPERATIONAL SAFETY SPECIFICATION

SAFETY DISCLAIMER

The technical information, diagnostic guides, error codes, and AI-generated suggestions provided on this website are intended exclusively for certified and qualified professionals. Appliance repair involves severe electrical hazards, high voltages, and mechanical risks that can result in fatal injury or severe property damage. If you are not a trained technician, do not attempt to repair any appliances. CodesErreur assumes no responsibility or liability for any damage, injury, or consequential losses resulting from the use of the information provided on this platform. You use all information entirely at your own risk.

© 2026 CodesErreur. All rights reserved.

Official Swiss Repair Partner: Electroassistance Terms of Service Privacy Policy