Zoppas PDF Series / Cristallo / Sanix Dishwasher: Circulation pump inverter DC bus overvoltage alarm i5B; rectified bus voltage exceeds 430V DC.
On Zoppas (Zoppas PDF Series / Cristallo / Sanix Dishwasher) models: Mains electrical grid voltage surge, rapid deceleration of heavy wash arm water momentum, or defective DC bus capacitor bank.
Measure incoming AC line voltage (nominal 230V AC ± 10%). Disconnect power for 10 minutes to discharge capacitors, then retest. Hold Avvio/Pausa and Annulla simultaneously for 5 seconds until the acoustic triple beep confirms memory clearing.