Skip to content
CodesErreur.comSWISS PRO ENGINE
Core Diagnostics
DiagnosticsBrandsOEM ManualsSpecialistsAI EngineerPRO
Workshop Tools
Diagnostic ToolsNEW
Hardware interfaces & test probes
Find Rating Plate
Locate exact E-Nr, PNC & serial codes
Parts Locator
Global OEM spare parts suppliers
Community & Career
Academy & Courses
Masterclasses by senior technicians
Certification ExamsPRO
Verify your B2B technical credentials
Elite Forum
Peer-to-peer field troubleshooting
Tech Jobs
B2B recruitment & field opportunities
Leaderboard
Global ranking of verified specialists
Certified Appliance Engineering EcosystemApply for Certification →
Language Selector
Account & Access
Upgrade PRO
Back to Search
OEM VERIFIED BENCH
OFFICIAL FAULT CODEi43
AEG
AEG // OFFICIAL DIAGNOSTIC BENCH

AEG i43

DishwasherWater Level Pressure Switch & Air Dome
Premium built-in dishwasher with open illuminated stainless steel interior and precision spray arms
Dishwasher
Other Brands Sharing Code i43:ElectroluxI43ZanussiI43Arthur MartinI43CastorI43FaureI43FrigidaireI43KelvinatorI43WestinghouseI43ZoppasI43

Symptom / Description

FAULT

AEG Favorit / ProClean / ComfortLift Series: Dynamic water level fluctuations alarm i43; abnormal pressure oscillations detected during circulation.

TELEMETRY // LIVESIG: FAULT_DETECTED

Root Cause

ROOT CAUSE

On AEG (AEG Favorit / ProClean / ComfortLift Series) models: Spray arms jammed against tall plates or cutlery, lower spray arm clogged with lemon seeds, or foaming from rinse aid overfill.

CIRCUIT // SUBSYSTEMLOGIC: ROOT_ISOLATED

Repair Instructions

UNLOCKED
1Ensure upper and lower spray arms rotate freely by hand. Clean clogged spray arm nozzle orifices with a needle. Check for excessive foam. Rotate selector to 12 o'clock (OFF), press and hold Start/Pause and Exit simultaneously for 4 seconds until the diagnostic LED sequence resets error memory.
AI diagnostic workshop engine analyzing appliance circuit schematics and error telemetry in real time
AI WORKSHOP PROTOCOL ENGINE
Direct extraction from OEM factory manuals & wiring schematics

Field Actions

DISPATCH
Need Help? Call a Certified TechnicianWorldwide AEG Parts Finder
Electrical & Safety Protocol

Always disconnect appliance from 230V/400V mains before opening panels. Use CAT III multimeter for circuit testing.

CALIBRATED BENCH PROTOCOL // CAT III 600V

Workshop Verification & Safety Checklist

WORKSHOP VERIFICATION PROTOCOLWater Level Pressure Switch & Air DomeDishwasher
2. Multimeter & Electrical Bench Tests (Ω)
MODE: OHMMETER (Ω)AUTO-RANGE
Precision digital multimeter probes measuring electrical resistance in Ohms on an appliance control board
CALIBRATED METROLOGY RESISTANCE BENCH (CAT III)
Nominal Resistance (Ω)
Mechanical: Continuity 0.0Ω–0.2Ω (Empty: 11-12, Full: 11-14). Electronic: 20Ω–45Ω coil resistance.NOMINAL
0 Ω (SHORT)CALIBRATED BAND∞ OL (OPEN)
▲ NOMINAL OPERATING WINDOW
Target Component:Mechanical Pressure Switch Contacts / Inductive Frequency Sensor
Test Pins & Connections
PROBE (+)
PROBE (-)
Across switch spade contacts with harness unplugged; electronic output: 40Hz–50Hz frequency signal
Tolerance & Diagnostic CriteriaMechanical switch contacts must transition cleanly on gentle breath pressure. Coil ~22Ω ±5%.
1. Pre-Intervention Electrical Safety Protocols
  • !Electrical Safety Protocol: Cut 230V mains power before accessing the upper chassis or pressure switch terminals.
  • !Drain appliance tub completely before disconnecting pressure switch sensing hoses.
  • !Never blow high-pressure compressed air into electronic analog pressure sensors: internal diaphragms will rupture!
3. Preliminary Mechanical & Visual Checks
  • Disconnect the silicone pressure tube from the lower air trap and inspect for soap sludge, lint, or water blockage.
  • Inspect the flexible rubber hose along its entire length for pinholes, cracks, or loose clamp fit.
  • Thoroughly flush the lower compression chamber (air dome) with hot water to dissolve detergent buildup.
Perform these diagnostic steps before triggering AI Deep Search or replacing boards.Certified Workshop Routine

Frequently Asked Questions: AEG I43

FAQ TREE
What does error code I43 mean on a AEG appliance?

AEG error code I43 indicates: AEG Favorit / ProClean / ComfortLift Series: Dynamic water level fluctuations alarm i43; abnormal pressure oscillations detected during circulation..

What is the root cause of AEG error code I43?

The primary root cause for AEG code I43 is: On AEG (AEG Favorit / ProClean / ComfortLift Series) models: Spray arms jammed against tall plates or cutlery, lower spray arm clogged with lemon seeds, or foaming from rinse aid overfill..

How do I fix or resolve AEG error code I43?

To resolve error code I43: Ensure upper and lower spray arms rotate freely by hand. Clean clogged spray arm nozzle orifices with a needle. Check for excessive foam. Rotate selector to 12 o'clock (OFF), press and hold Start/Pause and Exit simultaneously for 4 seconds until the diagnostic LED sequence resets error memory.

Is it safe to clear AEG error code I43 by resetting power?

Resetting power (unplugging for 5–10 minutes) clears temporary memory errors. However, if AEG code I43 persists, the physical component causing On AEG (AEG Favorit / ProClean / ComfortLift Series) models: Spray arms jammed against tall plates or cutlery, lower spray arm clogged with lemon seeds, or foaming from rinse aid overfill. must be inspected or replaced.

How do I test electrical resistance for AEG code I43 using a multimeter?

Set a digital multimeter to ohms (Ω). Disconnect power and test Mechanical Pressure Switch Contacts / Inductive Frequency Sensor across Across switch spade contacts with harness unplugged; electronic output: 40Hz–50Hz frequency signal. Expected nominal reading is Mechanical: Continuity 0.0Ω–0.2Ω (Empty: 11-12, Full: 11-14). Electronic: 20Ω–45Ω coil resistance.. Tolerance: Mechanical switch contacts must transition cleanly on gentle breath pressure. Coil ~22Ω ±5%..

What safety protocol must be followed before servicing AEG code I43?

Standard electrical safety protocol: 1. Disconnect 230V mains power before opening panels. 2. Verify zero voltage at test points. 3. Allow hot water or heating elements to cool below 30°C before handling.

Community Verification

COMMUNITY

Did this solution resolve the issue?

SEMANTIC KNOWLEDGE GRAPH // AEG

Related AEG Dishwasher Error Codes

Diagnostic Link Mesh14 OEM Cross-References

Cross-referenced diagnostic codes for technicians inspecting similar component subsystems.

i44Water Level Pressure Switch & Air Dome
AEG Favorit / ProClean / ComfortLift Series: Pressure sensor zero calibration error at cycle...
Inspect Protocol
i50Drive Motor, Inverter & Tachometer Sensor
AEG Favorit / ProClean / ComfortLift Series: Circulation wash pump motor general alarm i50; ...
Inspect Protocol
i51Drive Motor, Inverter & Tachometer Sensor
AEG Favorit / ProClean / ComfortLift Series: Circulation pump motor triac short circuit i51 ...
Inspect Protocol
i52Drive Motor, Inverter & Tachometer Sensor
AEG Favorit / ProClean / ComfortLift Series: Circulation pump motor tachometer signal missin...
Inspect Protocol
i53Heating Element, Thermostat & Safety Fuse
AEG Favorit / ProClean / ComfortLift Series: Circulation pump triac sensing circuit faulty i...
Inspect Protocol
i54Drive Motor, Inverter & Tachometer Sensor
AEG Favorit / ProClean / ComfortLift Series: Circulation pump motor rotor blocked or mechani...
Inspect Protocol
i55Drive Motor, Inverter & Tachometer Sensor
AEG Favorit / ProClean / ComfortLift Series: Circulation pump inverter overcurrent detected ...
Inspect Protocol
i56NTC Temperature Sensor & Thermistor
AEG Favorit / ProClean / ComfortLift Series: Circulation pump inverter thermal cutoff / moto...
Inspect Protocol
i57Drive Motor, Inverter & Tachometer Sensor
AEG Favorit / ProClean / ComfortLift Series: Circulation pump inverter phase current imbalan...
Inspect Protocol
i58Drive Motor, Inverter & Tachometer Sensor
AEG Favorit / ProClean / ComfortLift Series: Circulation pump motor phase disconnected or st...
Inspect Protocol
i59Water Level Pressure Switch & Air Dome
AEG Favorit / ProClean / ComfortLift Series: Circulation pump motor speed runaway or tachome...
Inspect Protocol
i5ADrive Motor, Inverter & Tachometer Sensor
AEG Favorit / ProClean / ComfortLift Series: Circulation pump inverter heat sink thermal thr...
Inspect Protocol
i5BDrive Motor, Inverter & Tachometer Sensor
AEG Favorit / ProClean / ComfortLift Series: Circulation pump inverter DC bus overvoltage al...
Inspect Protocol
i5CHeating Element, Thermostat & Safety Fuse
AEG Favorit / ProClean / ComfortLift Series: Circulation pump inverter DC bus undervoltage a...
Inspect Protocol
CodesErreur.com

Premium appliance diagnostics & repair database.
Powered by AI to help certified technicians worldwide.

Trusted by professionals in CH & FR

Platform

Search DatabasePRO Diagnostic AIPRODiagnostic ToolsBrands

Workshop Tools

Brands (87)OEM ManualsFind Rating PlateParts Locator

For Technicians

SpecialistsTechnician ForumTech JobsPremium

Corporate

Terms of ServicePrivacy PolicyOfficial Swiss Repair Partner: Electroassistance
OPERATIONAL SAFETY SPECIFICATION

SAFETY DISCLAIMER

The technical information, diagnostic guides, error codes, and AI-generated suggestions provided on this website are intended exclusively for certified and qualified professionals. Appliance repair involves severe electrical hazards, high voltages, and mechanical risks that can result in fatal injury or severe property damage. If you are not a trained technician, do not attempt to repair any appliances. CodesErreur assumes no responsibility or liability for any damage, injury, or consequential losses resulting from the use of the information provided on this platform. You use all information entirely at your own risk.

© 2026 CodesErreur. All rights reserved.

Official Swiss Repair Partner: Electroassistance Terms of Service Privacy Policy