Field Actions
DISPATCHAlways disconnect appliance from 230V/400V mains before opening panels. Use CAT III multimeter for circuit testing.
Frequently Asked Questions: Alaska E14
FAQ TREEWhat does error code E14 mean on a Alaska appliance?
Alaska error code E14 indicates: Alaska WA / WM Professional & Domestic Front-Load Washing Machine Series: Diagnostic fault code E14 registered by the microcomputer controller. Recirculation wash shower spray pump motor open circuit or impeller obstructed.
What is the root cause of Alaska error code E14?
The primary root cause for Alaska code E14 is: On Alaska commercial private label appliances distributed by Metro AG engineered with Metro OEM electronic washing chassis with 1950W calrod heater, 10 kΩ NTC sensor, and synchronous drain pump (165-215 Ω): recirculation pump coil burned out, lint blocking housing, or control triac open circuit. Metrological tolerance verification: recirculation pump coil resistance 170-220 Ω at 20°C; supply voltage 230 VAC 50 Hz..
How do I fix or resolve Alaska error code E14?
To resolve error code E14: Disconnect mains power before servicing. Unplug the harness at the main PCB and use a calibrated digital multimeter: unplug pump connector and measure winding expecting 170-220 Ω, clear shower jet nozzle and check hose for lint. Inspect contacts for pin oxidation or loose terminals. Replace defective part if out of tolerance, re-energize and clear error: rotate the program selector dial to Stop, press and hold the Start/Pause button for 5 seconds until all status LEDs blink once, then switch to Rinse.
Is it safe to clear Alaska error code E14 by resetting power?
Resetting power (unplugging for 5–10 minutes) clears temporary memory errors. However, if Alaska code E14 persists, the physical component causing On Alaska commercial private label appliances distributed by Metro AG engineered with Metro OEM electronic washing chassis with 1950W calrod heater, 10 kΩ NTC sensor, and synchronous drain pump (165-215 Ω): recirculation pump coil burned out, lint blocking housing, or control triac open circuit. Metrological tolerance verification: recirculation pump coil resistance 170-220 Ω at 20°C; supply voltage 230 VAC 50 Hz. must be inspected or replaced.
How do I test electrical resistance for Alaska code E14 using a multimeter?
Set a digital multimeter to ohms (Ω). Disconnect power and test NTC Temperature Sensor Probe (Thermistor) across Across sensor pins 1-2 (unplugged harness). Expected nominal reading is 4.8kΩ–12kΩ (at 20°C–25°C). Tolerance: Negative temperature coefficient: resistance drops smoothly when warmed with fingers. OL = open circuit..
What safety protocol must be followed before servicing Alaska code E14?
Standard electrical safety protocol: 1. Disconnect 230V mains power before opening panels. 2. Verify zero voltage at test points. 3. Allow hot water or heating elements to cool below 30°C before handling.
Community Verification
COMMUNITYDid this solution resolve the issue?