Ariston F4E1 — Refrigerator / Freezer
[ACTIVE]Ariston Active Oxygen Total NoFrost Refrigerator / Freezer: Diagnostic code F4E1 indicates fresh food compartment evaporator fan motor stalled or disconnected; air circulation fails.
On Ariston refrigerators (Ariston Aqualtis and HD Defrost electronic platform architecture): BLDC fan motor iced up, open stator windings (15–35 Ω), or loss of 12V DC power from main board.
Disconnect power. Remove evaporator cover panel. Verify fan blade spins freely without ice friction. Measure voltage at motor plug: expect 12.0V DC. If 12V present but motor will not spin, replace BLDC evaporator fan motor. Hold Alarm Reset pad for 5 seconds until audible alert ceases and active cooling LED illuminates steady.