Ariston F5 — Dishwasher
[ACTIVE]Ariston Hotpoint-Ariston 3D Zone Wash MaxiSpace Dishwasher: Wash rotor stalled or low spray pressure F5; circulation pump motor draws excessive current or spray arms fail to spin.
On Ariston dishwashers: Fruit pit, toothpick, or broken glass wedged inside circulation pump impeller, or defective motor run capacitor / BLDC drive.
Remove circulation pump assembly from sump. Clear debris from internal volute impeller. Test motor windings (BLDC 3-phase: 45–60 Ω symmetrical). Hold Start/Reset key for 5 seconds until cycle cancel chime sounds and drain pump completes sump evacuation.