Field Actions
DISPATCHAlways disconnect appliance from 230V/400V mains before opening panels. Use CAT III multimeter for circuit testing.
Frequently Asked Questions: Arthur Martin F2
FAQ TREEWhat does error code F2 mean on a Arthur Martin appliance?
Arthur Martin error code F2 indicates: Arthur Martin ARA / ARB Series / Silentic Froid Refrigerator: Evaporator coil sensor failure F2; automatic defrost termination monitoring fails, risking ice accumulation on coil..
What is the root cause of Arthur Martin error code F2?
The primary root cause for Arthur Martin code F2 is: On Arthur Martin (Arthur Martin ARA / ARB Series / Silentic Froid Refrigerator) models: Evaporator clip-on NTC probe defective or dislodged from refrigerant return bend, water ingress freezing inside probe sleeve, or open wire..
How do I fix or resolve Arthur Martin error code F2?
To resolve error code F2: Remove rear freezer panel. Test evaporator NTC resistance (typically ~2.5 kΩ at 25°C, rising to ~16.3 kΩ at -18°C). Clip firmly to copper return pipe. Hold Départ/Pause and Option buttons firmly for 5 seconds until the red indicator extinguishes and service memory resets.
Is it safe to clear Arthur Martin error code F2 by resetting power?
Resetting power (unplugging for 5–10 minutes) clears temporary memory errors. However, if Arthur Martin code F2 persists, the physical component causing On Arthur Martin (Arthur Martin ARA / ARB Series / Silentic Froid Refrigerator) models: Evaporator clip-on NTC probe defective or dislodged from refrigerant return bend, water ingress freezing inside probe sleeve, or open wire. must be inspected or replaced.
How do I test electrical resistance for Arthur Martin code F2 using a multimeter?
Set a digital multimeter to ohms (Ω). Disconnect power and test Compressor Motor Windings (Run/Start) & Defrost Heater across Across 3 compressor pins (Common, Run, Start): R(C-S) + R(C-R) = R(S-R). Winding to earth: >20MΩ (OL).. Expected nominal reading is 15Ω–25Ω (Run C-R), 20Ω–35Ω (Start C-S), 200Ω–400Ω (Defrost Heater). PTC Relay: 10Ω–30Ω at 25°C.. Tolerance: ±10%. Any low insulation resistance to casing (<2MΩ) trips the breaker. Defrost bimetal reads <0.5Ω when sub-zero..
What safety protocol must be followed before servicing Arthur Martin code F2?
Standard electrical safety protocol: 1. Disconnect 230V mains power before opening panels. 2. Verify zero voltage at test points. 3. Allow hot water or heating elements to cool below 30°C before handling.
Community Verification
COMMUNITYDid this solution resolve the issue?



