OFFICIAL FAULT CODEW02
Atlantic
Atlantic // OFFICIAL DIAGNOSTIC BENCH

Atlantic W02

Heat PumpNTC Temperature Sensor & Thermistor
Luxury front-loading washing machine in brushed titanium with illuminated dark glass drum
Heat Pump

Symptom / Description

FAULT

Atlantic Alféa Excellia / Extensa A.I. / Alféa Hybrid Duo Inverter Heat Pump: Diagnostic fault code W02 registered by the microcomputer controller. Hydronic primary circuit flow and return temperature spread warning

TELEMETRY // LIVESIG: FAULT_DETECTED

Root Cause

ROOT CAUSE

On Atlantic appliances engineered with co-developed Fujitsu twin-rotary DC inverter outdoor stage, Siemens Navistem / RVS hydraulic regulator, electronic expansion valve with 46 Ω stepper phases, and 10 kΩ NTC flow/return temperature sensors: water temperature spread between flow and return exceeding 12°C in cooling or 15°C in heating due to restricted hydraulic flow Metrological tolerance verification: design Delta T between 5°C and 8°C; minimum flow rate 800 L/h.

CIRCUIT // SUBSYSTEMLOGIC: ROOT_ISOLATED

Repair Instructions

UNLOCKED
1Disconnect mains power before servicing. Unplug the harness at the main PCB and use a calibrated digital multimeter: clean inline dirt strainer, bleed radiators/underfloor circuits, and increase Wilo pump speed setting. Inspect contacts for pin oxidation or loose terminals. Replace defective part if out of tolerance, re-energize and clear error: On the Navistem user controller: press OK and hold the 'i' button for 3 seconds to access Specialist mode. Go to line 6700-6800 (Diagnostics), select 'Reset fault log' and set to 'Yes', then press OK. For hard lockout, switch off the 230V/400V mains breaker for 60 seconds to discharge the DC link.
AI diagnostic workshop engine analyzing appliance circuit schematics and error telemetry in real time
AI WORKSHOP PROTOCOL ENGINE
Direct extraction from OEM factory manuals & wiring schematics

Field Actions

DISPATCH
Need Help? Call a Certified TechnicianWorldwide Atlantic Parts Finder
Electrical & Safety Protocol

Always disconnect appliance from 230V/400V mains before opening panels. Use CAT III multimeter for circuit testing.

CALIBRATED BENCH PROTOCOL // CAT III 600V

Workshop Verification & Safety Checklist

WORKSHOP VERIFICATION PROTOCOLNTC Temperature Sensor & ThermistorAir Conditioner / Heat Pump
2. Multimeter & Electrical Bench Tests (Ω)
MODE: OHMMETER (Ω)AUTO-RANGE
Precision digital multimeter probes measuring electrical resistance in Ohms on an appliance control board
CALIBRATED METROLOGY RESISTANCE BENCH (CAT III)
Nominal Resistance (Ω)
4.8kΩ–12kΩ (at 20°C–25°C)NOMINAL
0 Ω (SHORT)CALIBRATED BAND∞ OL (OPEN)
▲ NOMINAL OPERATING WINDOW
Target Component:NTC Temperature Sensor Probe (Thermistor)
Test Pins & Connections
PROBE (+)
PROBE (-)
Across sensor pins 1-2 (unplugged harness)
Tolerance & Diagnostic CriteriaNegative temperature coefficient: resistance drops smoothly when warmed with fingers. OL = open circuit.
1. Pre-Intervention Electrical Safety Protocols
  • !Electrical Safety Protocol: Disconnect 230V electrical mains power before removing appliance side or rear panels.
  • !Ensure tub water or heating chamber has cooled below 30°C before unclipping thermistor probe.
  • !Use CAT III 600V/1000V insulated test probes when tng at PCB edge connectors.
3. Preliminary Mechanical & Visual Checks
  • Inspect sensor immersion sleeve for calcification, limescale scale, or thermal paste degradation.
  • Check wiring harness for pinch points, chafing against chassis metal, and terminal pin oxidation.
  • Verify probe is firmly seated in its rubber grommet or bracket inside the water/air circuit.
Perform these diagnostic steps before triggering AI Deep Search or replacing boards.Certified Workshop Routine

Frequently Asked Questions: Atlantic W02

FAQ TREE
What does error code W02 mean on a Atlantic appliance?

Atlantic error code W02 indicates: Atlantic Alféa Excellia / Extensa A.I. / Alféa Hybrid Duo Inverter Heat Pump: Diagnostic fault code W02 registered by the microcomputer controller. Hydronic primary circuit flow and return temperature spread warning.

What is the root cause of Atlantic error code W02?

The primary root cause for Atlantic code W02 is: On Atlantic appliances engineered with co-developed Fujitsu twin-rotary DC inverter outdoor stage, Siemens Navistem / RVS hydraulic regulator, electronic expansion valve with 46 Ω stepper phases, and 10 kΩ NTC flow/return temperature sensors: water temperature spread between flow and return exceeding 12°C in cooling or 15°C in heating due to restricted hydraulic flow Metrological tolerance verification: design Delta T between 5°C and 8°C; minimum flow rate 800 L/h..

How do I fix or resolve Atlantic error code W02?

To resolve error code W02: Disconnect mains power before servicing. Unplug the harness at the main PCB and use a calibrated digital multimeter: clean inline dirt strainer, bleed radiators/underfloor circuits, and increase Wilo pump speed setting. Inspect contacts for pin oxidation or loose terminals. Replace defective part if out of tolerance, re-energize and clear error: On the Navistem user controller: press OK and hold the 'i' button for 3 seconds to access Specialist mode. Go to line 6700-6800 (Diagnostics), select 'Reset fault log' and set to 'Yes', then press OK. For hard lockout, switch off the 230V/400V mains breaker for 60 seconds to discharge the DC link.

Is it safe to clear Atlantic error code W02 by resetting power?

Resetting power (unplugging for 5–10 minutes) clears temporary memory errors. However, if Atlantic code W02 persists, the physical component causing On Atlantic appliances engineered with co-developed Fujitsu twin-rotary DC inverter outdoor stage, Siemens Navistem / RVS hydraulic regulator, electronic expansion valve with 46 Ω stepper phases, and 10 kΩ NTC flow/return temperature sensors: water temperature spread between flow and return exceeding 12°C in cooling or 15°C in heating due to restricted hydraulic flow Metrological tolerance verification: design Delta T between 5°C and 8°C; minimum flow rate 800 L/h. must be inspected or replaced.

How do I test electrical resistance for Atlantic code W02 using a multimeter?

Set a digital multimeter to ohms (Ω). Disconnect power and test NTC Temperature Sensor Probe (Thermistor) across Across sensor pins 1-2 (unplugged harness). Expected nominal reading is 4.8kΩ–12kΩ (at 20°C–25°C). Tolerance: Negative temperature coefficient: resistance drops smoothly when warmed with fingers. OL = open circuit..

What safety protocol must be followed before servicing Atlantic code W02?

Standard electrical safety protocol: 1. Disconnect 230V mains power before opening panels. 2. Verify zero voltage at test points. 3. Allow hot water or heating elements to cool below 30°C before handling.

Community Verification

COMMUNITY

Did this solution resolve the issue?

SEMANTIC KNOWLEDGE GRAPH // ATLANTIC

Related Atlantic Air Conditioner / Heat Pump Error Codes

Diagnostic Link Mesh14 OEM Cross-References

Cross-referenced diagnostic codes for technicians inspecting similar component subsystems.

W03NTC Temperature Sensor & Thermistor
Atlantic Alféa Excellia / Extensa A.I. / Alféa Hybrid Duo Inverter Heat Pump: Diagnostic fau...
Inspect Protocol
W05NTC Temperature Sensor & Thermistor
Atlantic Alféa Excellia / Extensa A.I. / Alféa Hybrid Duo Inverter Heat Pump: Diagnostic fau...
Inspect Protocol
W10NTC Temperature Sensor & Thermistor
Atlantic Alféa Excellia / Extensa A.I. / Alféa Hybrid Duo Inverter Heat Pump: Diagnostic fau...
Inspect Protocol
W14NTC Temperature Sensor & Thermistor
Atlantic Alféa Excellia / Extensa A.I. / Alféa Hybrid Duo Inverter Heat Pump: Diagnostic fau...
Inspect Protocol
W20NTC Temperature Sensor & Thermistor
Atlantic Alféa Excellia / Extensa A.I. / Alféa Hybrid Duo Inverter Heat Pump: Diagnostic fau...
Inspect Protocol
W25NTC Temperature Sensor & Thermistor
Atlantic Alféa Excellia / Extensa A.I. / Alféa Hybrid Duo Inverter Heat Pump: Diagnostic fau...
Inspect Protocol
11NTC Temperature Sensor & Thermistor
Atlantic Alféa Excellia / Extensa A.I. / Alféa Hybrid Duo Inverter Heat Pump: Diagnostic fau...
Inspect Protocol
12NTC Temperature Sensor & Thermistor
Atlantic Alféa Excellia / Extensa A.I. / Alféa Hybrid Duo Inverter Heat Pump: Diagnostic fau...
Inspect Protocol
14NTC Temperature Sensor & Thermistor
Atlantic Alféa Excellia / Extensa A.I. / Alféa Hybrid Duo Inverter Heat Pump: Diagnostic fau...
Inspect Protocol
18NTC Temperature Sensor & Thermistor
Atlantic Alféa Excellia / Extensa A.I. / Alféa Hybrid Duo Inverter Heat Pump: Diagnostic fau...
Inspect Protocol
Er 01NTC Temperature Sensor & Thermistor
Atlantic Alféa Excellia / Extensa A.I. / Alféa Hybrid Duo Inverter Heat Pump: Diagnostic fau...
Inspect Protocol
Er 02NTC Temperature Sensor & Thermistor
Atlantic Alféa Excellia / Extensa A.I. / Alféa Hybrid Duo Inverter Heat Pump: Diagnostic fau...
Inspect Protocol
Er 03NTC Temperature Sensor & Thermistor
Atlantic Alféa Excellia / Extensa A.I. / Alféa Hybrid Duo Inverter Heat Pump: Diagnostic fau...
Inspect Protocol
Er 04NTC Temperature Sensor & Thermistor
Atlantic Alféa Excellia / Extensa A.I. / Alféa Hybrid Duo Inverter Heat Pump: Diagnostic fau...
Inspect Protocol
CodesErreur.com

Premium appliance diagnostics & repair database.
Powered by AI to help certified technicians worldwide.

Trusted by professionals in CH & FR

Platform

Search DatabasePRO Diagnostic AIPRODiagnostic ToolsBrands

Workshop Tools

Brands (87)OEM ManualsFind Rating PlateParts Locator

For Technicians

SpecialistsTechnician ForumTech JobsPremium

Corporate

Terms of ServicePrivacy PolicyOfficial Swiss Repair Partner: Electroassistance
OPERATIONAL SAFETY SPECIFICATION

SAFETY DISCLAIMER

The technical information, diagnostic guides, error codes, and AI-generated suggestions provided on this website are intended exclusively for certified and qualified professionals. Appliance repair involves severe electrical hazards, high voltages, and mechanical risks that can result in fatal injury or severe property damage. If you are not a trained technician, do not attempt to repair any appliances. CodesErreur assumes no responsibility or liability for any damage, injury, or consequential losses resulting from the use of the information provided on this platform. You use all information entirely at your own risk.

© 2026 CodesErreur. All rights reserved.

Official Swiss Repair Partner: Electroassistance Terms of Service Privacy Policy