Bauknecht F4 — Dishwasher
[ACTIVE]Bauknecht PowerClean & GentlePower MaxiSpace Pro Dishwasher: Draining timeout failure F4; water level in hydraulic sump fails to drop below empty threshold within 4 minutes.
On Bauknecht dishwashers: Sump microfilter blocked by food soil, kinked drain hose, blocked non-return flap valve, or jammed drain pump impeller.
Remove and wash central fine mesh filters. Check drain impeller under sump cover for glass shards. Measure pump coil resistance (160–185 Ω). Hold Reset/Cancel button for 3 seconds until drain pump evacuates water and LED displays '0:01'.