OEM VERIFIED BENCH
OFFICIAL FAULT CODEFC
Bauknecht
Bauknecht // OFFICIAL DIAGNOSTIC BENCH

Bauknecht FC

DishwasherDrainage System & Drain Pump
Premium built-in dishwasher with open illuminated stainless steel interior and precision spray arms
Dishwasher
Other Brands Sharing Code FC:WhirlpoolFCIndesitFCAristonFCAirluxFCGEFCGree / MaceFCHotpointFCIgnisFC

Symptom / Description

FAULT

Bauknecht PowerClean & GentlePower MaxiSpace Pro Dishwasher: Water softener hardness sensor circuit fault FC; salt concentration conductivity measurement signal interrupted.

TELEMETRY // LIVESIG: FAULT_DETECTED

Root Cause

ROOT CAUSE

On Bauknecht dishwashers: Salt bridge in brine tank preventing sensor contact, corroded conductivity electrode pins, or disconnected softener wiring harness.

CIRCUIT // SUBSYSTEMLOGIC: ROOT_ISOLATED

Repair Instructions

UNLOCKED
1Stir salt container with wooden spoon to break crusts. Add 500ml warm water. Clean electrode pins and check wiring continuity to main control PCB. Hold Reset/Cancel button for 3 seconds until drain pump evacuates water and LED displays '0:01'.
AI diagnostic workshop engine analyzing appliance circuit schematics and error telemetry in real time
AI WORKSHOP PROTOCOL ENGINE
Direct extraction from OEM factory manuals & wiring schematics

Field Actions

DISPATCH
Need Help? Call a Certified TechnicianWorldwide Bauknecht Parts Finder
Electrical & Safety Protocol

Always disconnect appliance from 230V/400V mains before opening panels. Use CAT III multimeter for circuit testing.

CALIBRATED BENCH PROTOCOL // CAT III 600V

Workshop Verification & Safety Checklist

WORKSHOP VERIFICATION PROTOCOLDrainage System & Drain PumpDishwasher
2. Multimeter & Electrical Bench Tests (Ω)
MODE: OHMMETER (Ω)AUTO-RANGE
Precision digital multimeter probes measuring electrical resistance in Ohms on an appliance control board
CALIBRATED METROLOGY RESISTANCE BENCH (CAT III)
Nominal Resistance (Ω)
160Ω–220Ω (Sync 230V) / 20Ω–45Ω (3-Phase BLDC)NOMINAL
0 Ω (SHORT)CALIBRATED BAND∞ OL (OPEN)
▲ NOMINAL OPERATING WINDOW
Target Component:Drain Pump Motor Stator Coils
Test Pins & Connections
PROBE (+)
PROBE (-)
Across pump motor spade terminals (L-N unclipped)
Tolerance & Diagnostic Criteria±10% balance. Insulation resistance between coil and motor chassis must exceed 20MΩ.
1. Pre-Intervention Electrical Safety Protocols
  • !Electrical Safety Protocol: Isolate 230V mains power before accessing the lower pump housing.
  • !Prepare a shallow basin and absorption towels: expect 3 to 10 liters of stagnant trapped water upon filter opening.
  • !Beware of sharp foreign objects (broken glass, needles, screws) trapped inside the impeller cavity.
3. Preliminary Mechanical & Visual Checks
  • Unscrew coin trap filter and clear all foreign debris (coins, hairpins, bra underwires).
  • Rotate pump impeller manually: synchronous magnetic rotors should snap cleanly in 90° intervals without jamming.
  • Check drain hose for kinks, blockages, or unpunched sink spigots; verify drain height is between 65cm and 100cm.
Perform these diagnostic steps before triggering AI Deep Search or replacing boards.Certified Workshop Routine

Frequently Asked Questions: Bauknecht FC

FAQ TREE
What does error code FC mean on a Bauknecht appliance?

Bauknecht error code FC indicates: Bauknecht PowerClean & GentlePower MaxiSpace Pro Dishwasher: Water softener hardness sensor circuit fault FC; salt concentration conductivity measurement signal interrupted..

What is the root cause of Bauknecht error code FC?

The primary root cause for Bauknecht code FC is: On Bauknecht dishwashers: Salt bridge in brine tank preventing sensor contact, corroded conductivity electrode pins, or disconnected softener wiring harness..

How do I fix or resolve Bauknecht error code FC?

To resolve error code FC: Stir salt container with wooden spoon to break crusts. Add 500ml warm water. Clean electrode pins and check wiring continuity to main control PCB. Hold Reset/Cancel button for 3 seconds until drain pump evacuates water and LED displays '0:01'.

Is it safe to clear Bauknecht error code FC by resetting power?

Resetting power (unplugging for 5–10 minutes) clears temporary memory errors. However, if Bauknecht code FC persists, the physical component causing On Bauknecht dishwashers: Salt bridge in brine tank preventing sensor contact, corroded conductivity electrode pins, or disconnected softener wiring harness. must be inspected or replaced.

How do I test electrical resistance for Bauknecht code FC using a multimeter?

Set a digital multimeter to ohms (Ω). Disconnect power and test Drain Pump Motor Stator Coils across Across pump motor spade terminals (L-N unclipped). Expected nominal reading is 160Ω–220Ω (Sync 230V) / 20Ω–45Ω (3-Phase BLDC). Tolerance: ±10% balance. Insulation resistance between coil and motor chassis must exceed 20MΩ..

What safety protocol must be followed before servicing Bauknecht code FC?

Standard electrical safety protocol: 1. Disconnect 230V mains power before opening panels. 2. Verify zero voltage at test points. 3. Allow hot water or heating elements to cool below 30°C before handling.

Community Verification

COMMUNITY

Did this solution resolve the issue?

SEMANTIC KNOWLEDGE GRAPH // BAUKNECHT

Related Bauknecht Dishwasher Error Codes

Diagnostic Link Mesh14 OEM Cross-References

Cross-referenced diagnostic codes for technicians inspecting similar component subsystems.

FEDrainage System & Drain Pump
Bauknecht PowerClean & GentlePower MaxiSpace Pro Dishwasher: Control board microcontroller E...
Inspect Protocol
HNTC Temperature Sensor & Thermistor
Bauknecht H: NTC temperature sensor signal out of range (open or short circuit) in Dishwasher.
Inspect Protocol
E1NTC Temperature Sensor & Thermistor
Bauknecht PowerClean & GentlePower MaxiSpace Pro Dishwasher: Electronic temperature sensing ...
Inspect Protocol
E2Water Level Pressure Switch & Air Dome
Bauknecht PowerClean & GentlePower MaxiSpace Pro Dishwasher: AquaStop base pan float switch ...
Inspect Protocol
E3Drainage System & Drain Pump
Bauknecht PowerClean & GentlePower MaxiSpace Pro Dishwasher: Wash heating circuit open error...
Inspect Protocol
E4Water Level Pressure Switch & Air Dome
Bauknecht PowerClean & GentlePower MaxiSpace Pro Dishwasher: Drain evacuation timeout E4; su...
Inspect Protocol
E5Drainage System & Drain Pump
Bauknecht PowerClean & GentlePower MaxiSpace Pro Dishwasher: Circulation pump speed feedback...
Inspect Protocol
E6Drainage System & Drain Pump
Bauknecht PowerClean & GentlePower MaxiSpace Pro Dishwasher: Slow water fill sequence E6; fl...
Inspect Protocol
E7Drainage System & Drain Pump
Bauknecht PowerClean & GentlePower MaxiSpace Pro Dishwasher: Flow sensor open circuit error ...
Inspect Protocol
E8Drainage System & Drain Pump
Bauknecht PowerClean & GentlePower MaxiSpace Pro Dishwasher: Motorized water diverter valve ...
Inspect Protocol
E9Water Level Pressure Switch & Air Dome
Bauknecht PowerClean & GentlePower MaxiSpace Pro Dishwasher: Overfill chamber safety trip E9...
Inspect Protocol
F1NTC Temperature Sensor & Thermistor
Bauknecht PowerClean & GentlePower MaxiSpace Pro Dishwasher: Wash water temperature sensor o...
Inspect Protocol
F10Drainage System & Drain Pump
Bauknecht PowerClean & GentlePower MaxiSpace Pro Dishwasher: Heating circuit safety relay st...
Inspect Protocol
F11Drainage System & Drain Pump
Bauknecht PowerClean & GentlePower MaxiSpace Pro Dishwasher: BLDC circulation pump inverter ...
Inspect Protocol
CodesErreur.com

Premium appliance diagnostics & repair database.
Powered by AI to help certified technicians worldwide.

Trusted by professionals in CH & FR

Platform

Search DatabasePRO Diagnostic AIPRODiagnostic ToolsBrands

Workshop Tools

Brands (87)OEM ManualsFind Rating PlateParts Locator

For Technicians

SpecialistsTechnician ForumTech JobsPremium

Corporate

Terms of ServicePrivacy PolicyOfficial Swiss Repair Partner: Electroassistance
OPERATIONAL SAFETY SPECIFICATION

SAFETY DISCLAIMER

The technical information, diagnostic guides, error codes, and AI-generated suggestions provided on this website are intended exclusively for certified and qualified professionals. Appliance repair involves severe electrical hazards, high voltages, and mechanical risks that can result in fatal injury or severe property damage. If you are not a trained technician, do not attempt to repair any appliances. CodesErreur assumes no responsibility or liability for any damage, injury, or consequential losses resulting from the use of the information provided on this platform. You use all information entirely at your own risk.

© 2026 CodesErreur. All rights reserved.

Official Swiss Repair Partner: Electroassistance Terms of Service Privacy Policy