Beko E16 — Dryer
[ACTIVE]Beko RapiDry / EcoGentle / IronFinish Heat Pump Tumble Dryer: Automated condenser flush cleaning valve failure E16; self-cleaning wash cycle fails to flush lint from heat pump exchanger.
On Beko dryers with RapiDry hybrid heat-pump and heater system, EcoGentle low-temperature drying, and AquaWave gentle drum paddles: Open or shorted solenoid actuator coil on condenser flushing valve (~3.5–4.8 kΩ), mechanical scale calcification, or clogged flush nozzle.
Disconnect valve electrical leads. Measure solenoid coil resistance (~3.5–4.8 kΩ). Inspect water flush distributor channel and clear lint debris with nylon brush. Turn cycle selector to Off. Press and hold Start/Pause and Anti-Crease buttons simultaneously for 5 seconds until memory clears.