Field Actions
DISPATCHAlways disconnect appliance from 230V/400V mains before opening panels. Use CAT III multimeter for circuit testing.
Frequently Asked Questions: Bompani E1
FAQ TREEWhat does error code E1 mean on a Bompani appliance?
Bompani error code E1 indicates: Dishwasher will not start and may be beeping; anti-flood system activated..
What is the root cause of Bompani error code E1?
The primary root cause for Bompani code E1 is: A leak has been detected in the base of the machine, which has activated the float switch (Aquastop system)..
How do I fix or resolve Bompani error code E1?
To resolve error code E1: Unplug the appliance and check the base pan for water. Find and repair the source of the leak (e.g., loose hose, cracked tub, faulty seal). Dry the base and reset the float switch.
Is it safe to clear Bompani error code E1 by resetting power?
Resetting power (unplugging for 5–10 minutes) clears temporary memory errors. However, if Bompani code E1 persists, the physical component causing A leak has been detected in the base of the machine, which has activated the float switch (Aquastop system). must be inspected or replaced.
How do I test electrical resistance for Bompani code E1 using a multimeter?
Set a digital multimeter to ohms (Ω). Disconnect power and test Solenoid Valve Coil / Aquastop Pneumatic Valve across Across coil spade terminals (disconnect harness first). Expected nominal reading is 3.5kΩ–4.5kΩ (Standard 230V) / 2.0kΩ–4.2kΩ (Aquastop). Tolerance: ±10%. Open circuit (OL) indicates burned solenoid coil. Flowmeter turbine reed switch pulses on flow..
What safety protocol must be followed before servicing Bompani code E1?
Standard electrical safety protocol: 1. Disconnect 230V mains power before opening panels. 2. Verify zero voltage at test points. 3. Allow hot water or heating elements to cool below 30°C before handling.
Community Verification
COMMUNITYDid this solution resolve the issue?