Skip to content
CodesErreur.comSWISS PRO ENGINE
Core Diagnostics
DiagnosticsBrandsOEM ManualsSpecialistsAI EngineerPRO
Workshop Tools
Diagnostic ToolsNEW
Hardware interfaces & test probes
Find Rating Plate
Locate exact E-Nr, PNC & serial codes
Parts Locator
Global OEM spare parts suppliers
Community & Career
Academy & Courses
Masterclasses by senior technicians
Certification ExamsPRO
Verify your B2B technical credentials
Elite Forum
Peer-to-peer field troubleshooting
Tech Jobs
B2B recruitment & field opportunities
Leaderboard
Global ranking of verified specialists
Certified Appliance Engineering EcosystemApply for Certification →
Language Selector
Account & Access
Upgrade PRO
Back to Search
OEM VERIFIED BENCH
OFFICIAL FAULT CODEE15
Bosch
Bosch // OFFICIAL DIAGNOSTIC BENCH

Bosch E15

DishwasherWater Level Pressure Switch & Air Dome
Premium built-in dishwasher with open illuminated stainless steel interior and precision spray arms
Dishwasher
Select Appliance Type
0ms Instant Telemetry Switch
Other Brands Sharing Code E15:SiemensE15CandyE15NeffE15HooverE15GaggenauE15RosieresE15SangiorgioE15SharpE15SiltalE15ZerowattE15

Symptom / Description

FAULT

Bosch Serie 4 / Serie 6 / Serie 8 ActiveWater & PerfectDry Zeolith: AquaStop safety flood protection triggered E15; polystyrene float switch in base tray activated, drain pump runs continuously.

TELEMETRY // LIVESIG: FAULT_DETECTED

Root Cause

ROOT CAUSE

On Bosch dishwashers: Water leak into bottom drip tray from sump gasket, loose circulation pump hose, cracked water inlet matrix, or leaking door seal.

CIRCUIT // SUBSYSTEMLOGIC: ROOT_ISOLATED

Repair Instructions

UNLOCKED
1Disconnect power. Sponge water from bottom pan to drop float switch. Locate source of leak (often sump gasket; install Bosch sump repair kit 12005744). Hold Start/Reset key for 3 seconds until '0:01' appears, close door, allow 60s for drain completion, then power off.
AI diagnostic workshop engine analyzing appliance circuit schematics and error telemetry in real time
AI WORKSHOP PROTOCOL ENGINE
Direct extraction from OEM factory manuals & wiring schematics

Field Actions

DISPATCH
Need Help? Call a Certified TechnicianWorldwide Bosch Parts Finder
Electrical & Safety Protocol

Always disconnect appliance from 230V/400V mains before opening panels. Use CAT III multimeter for circuit testing.

CALIBRATED BENCH PROTOCOL // CAT III 600V

Workshop Verification & Safety Checklist

WORKSHOP VERIFICATION PROTOCOLWater Level Pressure Switch & Air DomeDishwasher
2. Multimeter & Electrical Bench Tests (Ω)
MODE: OHMMETER (Ω)AUTO-RANGE
Precision digital multimeter probes measuring electrical resistance in Ohms on an appliance control board
CALIBRATED METROLOGY RESISTANCE BENCH (CAT III)
Nominal Resistance (Ω)
Mechanical: Continuity 0.0Ω–0.2Ω (Empty: 11-12, Full: 11-14). Electronic: 20Ω–45Ω coil resistance.NOMINAL
0 Ω (SHORT)CALIBRATED BAND∞ OL (OPEN)
▲ NOMINAL OPERATING WINDOW
Target Component:Mechanical Pressure Switch Contacts / Inductive Frequency Sensor
Test Pins & Connections
PROBE (+)
PROBE (-)
Across switch spade contacts with harness unplugged; electronic output: 40Hz–50Hz frequency signal
Tolerance & Diagnostic CriteriaMechanical switch contacts must transition cleanly on gentle breath pressure. Coil ~22Ω ±5%.
1. Pre-Intervention Electrical Safety Protocols
  • !Electrical Safety Protocol: Cut 230V mains power before accessing the upper chassis or pressure switch terminals.
  • !Drain appliance tub completely before disconnecting pressure switch sensing hoses.
  • !Never blow high-pressure compressed air into electronic analog pressure sensors: internal diaphragms will rupture!
3. Preliminary Mechanical & Visual Checks
  • Disconnect the silicone pressure tube from the lower air trap and inspect for soap sludge, lint, or water blockage.
  • Inspect the flexible rubber hose along its entire length for pinholes, cracks, or loose clamp fit.
  • Thoroughly flush the lower compression chamber (air dome) with hot water to dissolve detergent buildup.
Perform these diagnostic steps before triggering AI Deep Search or replacing boards.Certified Workshop Routine

Frequently Asked Questions: Bosch E15

FAQ TREE
What does error code E15 mean on a Bosch appliance?

Bosch error code E15 indicates: Bosch Serie 4 / Serie 6 / Serie 8 ActiveWater & PerfectDry Zeolith: AquaStop safety flood protection triggered E15; polystyrene float switch in base tray activated, drain pump runs continuously..

What is the root cause of Bosch error code E15?

The primary root cause for Bosch code E15 is: On Bosch dishwashers: Water leak into bottom drip tray from sump gasket, loose circulation pump hose, cracked water inlet matrix, or leaking door seal..

How do I fix or resolve Bosch error code E15?

To resolve error code E15: Disconnect power. Sponge water from bottom pan to drop float switch. Locate source of leak (often sump gasket; install Bosch sump repair kit 12005744). Hold Start/Reset key for 3 seconds until '0:01' appears, close door, allow 60s for drain completion, then power off.

Is it safe to clear Bosch error code E15 by resetting power?

Resetting power (unplugging for 5–10 minutes) clears temporary memory errors. However, if Bosch code E15 persists, the physical component causing On Bosch dishwashers: Water leak into bottom drip tray from sump gasket, loose circulation pump hose, cracked water inlet matrix, or leaking door seal. must be inspected or replaced.

How do I test electrical resistance for Bosch code E15 using a multimeter?

Set a digital multimeter to ohms (Ω). Disconnect power and test Mechanical Pressure Switch Contacts / Inductive Frequency Sensor across Across switch spade contacts with harness unplugged; electronic output: 40Hz–50Hz frequency signal. Expected nominal reading is Mechanical: Continuity 0.0Ω–0.2Ω (Empty: 11-12, Full: 11-14). Electronic: 20Ω–45Ω coil resistance.. Tolerance: Mechanical switch contacts must transition cleanly on gentle breath pressure. Coil ~22Ω ±5%..

What safety protocol must be followed before servicing Bosch code E15?

Standard electrical safety protocol: 1. Disconnect 230V mains power before opening panels. 2. Verify zero voltage at test points. 3. Allow hot water or heating elements to cool below 30°C before handling.

Community Verification

COMMUNITY

Did this solution resolve the issue?

SEMANTIC KNOWLEDGE GRAPH // BOSCH

Related Bosch Dishwasher Error Codes

Diagnostic Link Mesh14 OEM Cross-References

Cross-referenced diagnostic codes for technicians inspecting similar component subsystems.

E16Drainage System & Drain Pump
Bosch Serie 4 / Serie 6 / Serie 8 ActiveWater & PerfectDry Zeolith: Uncontrolled water inflo...
Inspect Protocol
E17Drainage System & Drain Pump
Bosch Serie 4 / Serie 6 / Serie 8 ActiveWater & PerfectDry Zeolith: High water inlet pressur...
Inspect Protocol
E18Drainage System & Drain Pump
Bosch Serie 4 / Serie 6 / Serie 8 ActiveWater & PerfectDry Zeolith: Low water flow inlet tim...
Inspect Protocol
E19Drainage System & Drain Pump
Bosch Serie 4 / Serie 6 / Serie 8 ActiveWater & PerfectDry Zeolith: Dispenser actuator / hea...
Inspect Protocol
E20Drainage System & Drain Pump
Bosch Serie 4 / Serie 6 / Serie 8 ActiveWater & PerfectDry Zeolith: Circulation pump BLDC wi...
Inspect Protocol
E21Drainage System & Drain Pump
Bosch Serie 4 / Serie 6 / Serie 8 ActiveWater & PerfectDry Zeolith: Circulation pump motor j...
Inspect Protocol
E22Drainage System & Drain Pump
Bosch Serie 4 / Serie 6 / Serie 8 ActiveWater & PerfectDry Zeolith: Sump filter blocked / re...
Inspect Protocol
E23Drainage System & Drain Pump
Bosch Serie 4 / Serie 6 / Serie 8 ActiveWater & PerfectDry Zeolith: Drain pump winding resis...
Inspect Protocol
E24Drainage System & Drain Pump
Bosch Serie 4 / Serie 6 / Serie 8 ActiveWater & PerfectDry Zeolith: Drain hose obstruction /...
Inspect Protocol
E25Drainage System & Drain Pump
Bosch Serie 4 / Serie 6 / Serie 8 ActiveWater & PerfectDry Zeolith: Drain pump impeller lock...
Inspect Protocol
E26Drainage System & Drain Pump
Bosch Serie 4 / Serie 6 / Serie 8 ActiveWater & PerfectDry Zeolith: Water switch diverter va...
Inspect Protocol
E27Drainage System & Drain Pump
Bosch Serie 4 / Serie 6 / Serie 8 ActiveWater & PerfectDry Zeolith: Mains undervoltage detec...
Inspect Protocol
E28Drainage System & Drain Pump
Bosch Serie 4 / Serie 6 / Serie 8 ActiveWater & PerfectDry Zeolith: Turbidity AquaSensor opt...
Inspect Protocol
E29Drainage System & Drain Pump
Bosch Serie 4 / Serie 6 / Serie 8 ActiveWater & PerfectDry Zeolith: Mains supply frequency o...
Inspect Protocol
CodesErreur.com

Premium appliance diagnostics & repair database.
Powered by AI to help certified technicians worldwide.

Trusted by professionals in CH & FR

Platform

Search DatabasePRO Diagnostic AIPRODiagnostic ToolsBrands

Workshop Tools

Brands (87)OEM ManualsFind Rating PlateParts Locator

For Technicians

SpecialistsTechnician ForumTech JobsPremium

Corporate

Terms of ServicePrivacy PolicyOfficial Swiss Repair Partner: Electroassistance
OPERATIONAL SAFETY SPECIFICATION

SAFETY DISCLAIMER

The technical information, diagnostic guides, error codes, and AI-generated suggestions provided on this website are intended exclusively for certified and qualified professionals. Appliance repair involves severe electrical hazards, high voltages, and mechanical risks that can result in fatal injury or severe property damage. If you are not a trained technician, do not attempt to repair any appliances. CodesErreur assumes no responsibility or liability for any damage, injury, or consequential losses resulting from the use of the information provided on this platform. You use all information entirely at your own risk.

© 2026 CodesErreur. All rights reserved.

Official Swiss Repair Partner: Electroassistance Terms of Service Privacy Policy