Bosch E20 — Dishwasher
[ACTIVE]Bosch Serie 4 / Serie 6 / Serie 8 ActiveWater & PerfectDry Zeolith: Circulation pump BLDC winding resistance fault E20; phase impedance imbalance or open coil detected by inverter.
On Bosch dishwashers: Open or shorted winding in 3-phase BLDC heat pump motor, moisture ingress in motor plug, or inverter driver failure.
Disconnect power. Measure 3-phase motor winding resistances between pins 1-2, 2-3, 1-3 on heat pump motor (nominal ~88 Ω ± 5% across all 3 phases). Hold Start/Reset key for 3 seconds until '0:01' appears, close door, allow 60s for drain completion, then power off.