OEM VERIFIED BENCH
OFFICIAL FAULT CODEE3100
Bosch
Bosch // OFFICIAL DIAGNOSTIC BENCH

Bosch E3100

DishwasherNTC Temperature Sensor & Thermistor
Premium built-in dishwasher with open illuminated stainless steel interior and precision spray arms
Dishwasher
Other Brands Sharing Code E3100:SiemensE3100NeffE3100GaggenauE3100

Symptom / Description

FAULT

Bosch Serie 4 / Serie 6 / Serie 8 ActiveWater & PerfectDry Zeolith: Zeolith container NTC sensor open circuit E3100; electronic controller cannot monitor zeolite drying bed temperature.

TELEMETRY // LIVESIG: FAULT_DETECTED

Root Cause

ROOT CAUSE

On Bosch dishwashers: Broken lead wire to Zeolith container NTC sensor, corrosion on sensor connector terminals, or defective thermistor pellet.

CIRCUIT // SUBSYSTEMLOGIC: ROOT_ISOLATED

Repair Instructions

UNLOCKED
1Measure Zeolith NTC sensor resistance across terminals (nominal ~10 kΩ at 25°C). Inspect wiring harness beneath right tub skirt. Replace NTC if open circuit. Hold Start/Reset key for 3 seconds until '0:01' appears, close door, allow 60s for drain completion, then power off.
AI diagnostic workshop engine analyzing appliance circuit schematics and error telemetry in real time
AI WORKSHOP PROTOCOL ENGINE
Direct extraction from OEM factory manuals & wiring schematics

Field Actions

DISPATCH
Need Help? Call a Certified TechnicianWorldwide Bosch Parts Finder
Electrical & Safety Protocol

Always disconnect appliance from 230V/400V mains before opening panels. Use CAT III multimeter for circuit testing.

CALIBRATED BENCH PROTOCOL // CAT III 600V

Workshop Verification & Safety Checklist

WORKSHOP VERIFICATION PROTOCOLNTC Temperature Sensor & ThermistorDishwasher
2. Multimeter & Electrical Bench Tests (Ω)
MODE: OHMMETER (Ω)AUTO-RANGE
Precision digital multimeter probes measuring electrical resistance in Ohms on an appliance control board
CALIBRATED METROLOGY RESISTANCE BENCH (CAT III)
Nominal Resistance (Ω)
4.8kΩ–12kΩ (at 20°C–25°C)NOMINAL
0 Ω (SHORT)CALIBRATED BAND∞ OL (OPEN)
▲ NOMINAL OPERATING WINDOW
Target Component:NTC Temperature Sensor Probe (Thermistor)
Test Pins & Connections
PROBE (+)
PROBE (-)
Across sensor pins 1-2 (unplugged harness)
Tolerance & Diagnostic CriteriaNegative temperature coefficient: resistance drops smoothly when warmed with fingers. OL = open circuit.
1. Pre-Intervention Electrical Safety Protocols
  • !Electrical Safety Protocol: Disconnect 230V electrical mains power before removing appliance side or rear panels.
  • !Ensure tub water or heating chamber has cooled below 30°C before unclipping thermistor probe.
  • !Use CAT III 600V/1000V insulated test probes when tng at PCB edge connectors.
3. Preliminary Mechanical & Visual Checks
  • Inspect sensor immersion sleeve for calcification, limescale scale, or thermal paste degradation.
  • Check wiring harness for pinch points, chafing against chassis metal, and terminal pin oxidation.
  • Verify probe is firmly seated in its rubber grommet or bracket inside the water/air circuit.
Perform these diagnostic steps before triggering AI Deep Search or replacing boards.Certified Workshop Routine

Frequently Asked Questions: Bosch E3100

FAQ TREE
What does error code E3100 mean on a Bosch appliance?

Bosch error code E3100 indicates: Bosch Serie 4 / Serie 6 / Serie 8 ActiveWater & PerfectDry Zeolith: Zeolith container NTC sensor open circuit E3100; electronic controller cannot monitor zeolite drying bed temperature..

What is the root cause of Bosch error code E3100?

The primary root cause for Bosch code E3100 is: On Bosch dishwashers: Broken lead wire to Zeolith container NTC sensor, corrosion on sensor connector terminals, or defective thermistor pellet..

How do I fix or resolve Bosch error code E3100?

To resolve error code E3100: Measure Zeolith NTC sensor resistance across terminals (nominal ~10 kΩ at 25°C). Inspect wiring harness beneath right tub skirt. Replace NTC if open circuit. Hold Start/Reset key for 3 seconds until '0:01' appears, close door, allow 60s for drain completion, then power off.

Is it safe to clear Bosch error code E3100 by resetting power?

Resetting power (unplugging for 5–10 minutes) clears temporary memory errors. However, if Bosch code E3100 persists, the physical component causing On Bosch dishwashers: Broken lead wire to Zeolith container NTC sensor, corrosion on sensor connector terminals, or defective thermistor pellet. must be inspected or replaced.

How do I test electrical resistance for Bosch code E3100 using a multimeter?

Set a digital multimeter to ohms (Ω). Disconnect power and test NTC Temperature Sensor Probe (Thermistor) across Across sensor pins 1-2 (unplugged harness). Expected nominal reading is 4.8kΩ–12kΩ (at 20°C–25°C). Tolerance: Negative temperature coefficient: resistance drops smoothly when warmed with fingers. OL = open circuit..

What safety protocol must be followed before servicing Bosch code E3100?

Standard electrical safety protocol: 1. Disconnect 230V mains power before opening panels. 2. Verify zero voltage at test points. 3. Allow hot water or heating elements to cool below 30°C before handling.

Community Verification

COMMUNITY

Did this solution resolve the issue?

SEMANTIC KNOWLEDGE GRAPH // BOSCH

Related Bosch Dishwasher Error Codes

Diagnostic Link Mesh14 OEM Cross-References

Cross-referenced diagnostic codes for technicians inspecting similar component subsystems.

E3200Drainage System & Drain Pump
Bosch Serie 4 / Serie 6 / Serie 8 ActiveWater & PerfectDry Zeolith: Zeolith regeneration hea...
Inspect Protocol
E6101Water Level Pressure Switch & Air Dome
Bosch Serie 4 / Serie 6 / Serie 8 ActiveWater & PerfectDry Zeolith: Drain safety monitoring ...
Inspect Protocol
E6900Drainage System & Drain Pump
Bosch Serie 4 / Serie 6 / Serie 8 ActiveWater & PerfectDry Zeolith: Main inverter power modu...
Inspect Protocol
E9001Drainage System & Drain Pump
Bosch Serie 4 / Serie 6 / Serie 8 ActiveWater & PerfectDry Zeolith: Low voltage DC power rai...
Inspect Protocol
E9210Drainage System & Drain Pump
Bosch Serie 4 / Serie 6 / Serie 8 ActiveWater & PerfectDry Zeolith: Water hardness ion-excha...
Inspect Protocol
HElectronic Control Board (PCB) & Bus Communications
After the flash fires, "H" appears on the display
Inspect Protocol
h:00 – h:24Drainage System & Drain Pump
Delay start countdown display active (h:00 to h:24); wash cycle execution deferred.
Inspect Protocol
P0 Switchmirror 1Electronic Control Board (PCB) & Bus Communications
Error message „P0 Switchmirror 1“ or barre colorate south display with capacitive control pa...
Inspect Protocol
1Electronic Control Board (PCB) & Bus Communications
Error in the Aquasensor system (Error in Aquasensor system)
Inspect Protocol
16Electronic Control Board (PCB) & Bus Communications
Bosch 16: Operational cycle fault detected during Dishwasher program execution.
Inspect Protocol
2Electronic Control Board (PCB) & Bus Communications
Heizfehler (Heating error)
Inspect Protocol
4Water Level Pressure Switch & Air Dome
Bosch 4: Water inlet / filling timeout in Dishwasher; appliance fails to fill to minimum ope...
Inspect Protocol
8NTC Temperature Sensor & Thermistor
Fault detected in the NTC temperature sensor circuit
Inspect Protocol
E12Drainage System & Drain Pump
Bosch Serie 4 / Serie 6 / Serie 8 ActiveWater & PerfectDry Zeolith: Severe lime scale build-...
Inspect Protocol
CodesErreur.com

Premium appliance diagnostics & repair database.
Powered by AI to help certified technicians worldwide.

Trusted by professionals in CH & FR

Platform

Search DatabasePRO Diagnostic AIPRODiagnostic ToolsBrands

Workshop Tools

Brands (87)OEM ManualsFind Rating PlateParts Locator

For Technicians

SpecialistsTechnician ForumTech JobsPremium

Corporate

Terms of ServicePrivacy PolicyOfficial Swiss Repair Partner: Electroassistance
OPERATIONAL SAFETY SPECIFICATION

SAFETY DISCLAIMER

The technical information, diagnostic guides, error codes, and AI-generated suggestions provided on this website are intended exclusively for certified and qualified professionals. Appliance repair involves severe electrical hazards, high voltages, and mechanical risks that can result in fatal injury or severe property damage. If you are not a trained technician, do not attempt to repair any appliances. CodesErreur assumes no responsibility or liability for any damage, injury, or consequential losses resulting from the use of the information provided on this platform. You use all information entirely at your own risk.

© 2026 CodesErreur. All rights reserved.

Official Swiss Repair Partner: Electroassistance Terms of Service Privacy Policy