OFFICIAL FAULT CODEE5116
Bosch
Bosch // OFFICIAL DIAGNOSTIC BENCH

Bosch E5116

OvenHeating Element, Thermostat & Safety Fuse
Integrated luxury convection oven and induction cooktop with illuminated touch controls
Oven
Other Brands Sharing Code E5116:SiemensE5116NeffE5116GaggenauE5116

Symptom / Description

FAULT

Bosch Serie 6 / Serie 8 4D Hotair & EcoClean Direct Pyrolytic Oven: Combi-microwave inverter magnetron heater open circuit E5116; magnetron filament open or high-voltage inverter output missing.

TELEMETRY // LIVESIG: FAULT_DETECTED

Root Cause

ROOT CAUSE

On Bosch ovens: Burned-out filament in 2M261 magnetron tube (nominal < 0.2 Ω), blown high-voltage fuse, or defective resonant inverter board.

CIRCUIT // SUBSYSTEMLOGIC: ROOT_ISOLATED

Repair Instructions

UNLOCKED
1DANGER: Disconnect mains and discharge high-voltage capacitor. Measure magnetron filament resistance across terminals (< 0.2 Ω; open if > 1 Ω). Turn function selector to 0, isolate power at circuit breaker for 60 seconds, restore power and set the digital clock.
AI diagnostic workshop engine analyzing appliance circuit schematics and error telemetry in real time
AI WORKSHOP PROTOCOL ENGINE
Direct extraction from OEM factory manuals & wiring schematics

Field Actions

DISPATCH
Need Help? Call a Certified TechnicianWorldwide Bosch Parts Finder
Electrical & Safety Protocol

Always disconnect appliance from 230V/400V mains before opening panels. Use CAT III multimeter for circuit testing.

CALIBRATED BENCH PROTOCOL // CAT III 600V

Workshop Verification & Safety Checklist

WORKSHOP VERIFICATION PROTOCOLHeating Element, Thermostat & Safety FuseOven / Microwave
2. Multimeter & Electrical Bench Tests (Ω)
MODE: OHMMETER (Ω)AUTO-RANGE
Precision digital multimeter probes measuring electrical resistance in Ohms on an appliance control board
CALIBRATED METROLOGY RESISTANCE BENCH (CAT III)
Nominal Resistance (Ω)
25Ω–28Ω (230V / 2000W) / <0.5Ω (Safety Klixon closed)NOMINAL
0 Ω (SHORT)CALIBRATED BAND∞ OL (OPEN)
▲ NOMINAL OPERATING WINDOW
Target Component:Immersion / Air Heating Element & Klixon Thermostat
Test Pins & Connections
PROBE (+)
PROBE (-)
Between element terminals (unwired). Insulation to earth casing: >20MΩ (OL)
Tolerance & Diagnostic CriteriaFormula R = V²/P (±5%). Any earth leakage reading below 2MΩ will trip the domestic 30mA RCD breaker.
1. Pre-Intervention Electrical Safety Protocols
  • !Electrical Safety Protocol: Cut electrical mains power. Never measure resistance on energized heating circuits.
  • !Ensure tub water or heating cavity is completely drained and cool to the touch before dismantling.
  • !Verify absolute zero voltage using an approved 2-pole voltage detector before touching element terminals.
3. Preliminary Mechanical & Visual Checks
  • Inspect heating element tube for calcification buildup, bulging, pinholes, or blistering.
  • Check wiring spade terminals for heat discoloration, burnt insulation, or loose crimps.
  • On thermal Klixon switches: check for manual red reset buttons and verify spring-loaded snap action.
Perform these diagnostic steps before triggering AI Deep Search or replacing boards.Certified Workshop Routine

Frequently Asked Questions: Bosch E5116

FAQ TREE
What does error code E5116 mean on a Bosch appliance?

Bosch error code E5116 indicates: Bosch Serie 6 / Serie 8 4D Hotair & EcoClean Direct Pyrolytic Oven: Combi-microwave inverter magnetron heater open circuit E5116; magnetron filament open or high-voltage inverter output missing..

What is the root cause of Bosch error code E5116?

The primary root cause for Bosch code E5116 is: On Bosch ovens: Burned-out filament in 2M261 magnetron tube (nominal < 0.2 Ω), blown high-voltage fuse, or defective resonant inverter board..

How do I fix or resolve Bosch error code E5116?

To resolve error code E5116: DANGER: Disconnect mains and discharge high-voltage capacitor. Measure magnetron filament resistance across terminals (< 0.2 Ω; open if > 1 Ω). Turn function selector to 0, isolate power at circuit breaker for 60 seconds, restore power and set the digital clock.

Is it safe to clear Bosch error code E5116 by resetting power?

Resetting power (unplugging for 5–10 minutes) clears temporary memory errors. However, if Bosch code E5116 persists, the physical component causing On Bosch ovens: Burned-out filament in 2M261 magnetron tube (nominal < 0.2 Ω), blown high-voltage fuse, or defective resonant inverter board. must be inspected or replaced.

How do I test electrical resistance for Bosch code E5116 using a multimeter?

Set a digital multimeter to ohms (Ω). Disconnect power and test Immersion / Air Heating Element & Klixon Thermostat across Between element terminals (unwired). Insulation to earth casing: >20MΩ (OL). Expected nominal reading is 25Ω–28Ω (230V / 2000W) / <0.5Ω (Safety Klixon closed). Tolerance: Formula R = V²/P (±5%). Any earth leakage reading below 2MΩ will trip the domestic 30mA RCD breaker..

What safety protocol must be followed before servicing Bosch code E5116?

Standard electrical safety protocol: 1. Disconnect 230V mains power before opening panels. 2. Verify zero voltage at test points. 3. Allow hot water or heating elements to cool below 30°C before handling.

Community Verification

COMMUNITY

Did this solution resolve the issue?

SEMANTIC KNOWLEDGE GRAPH // BOSCH

Related Bosch Oven / Microwave Error Codes

Diagnostic Link Mesh14 OEM Cross-References

Cross-referenced diagnostic codes for technicians inspecting similar component subsystems.

E516NTC Temperature Sensor & Thermistor
Core temperature probe (meat thermometer) circuit fault detected on the oven.
Inspect Protocol
E845Water Level Pressure Switch & Air Dome
Bosch Serie 6 / Serie 8 4D Hotair & EcoClean Direct Pyrolytic Oven: Combi-steam boiler water...
Inspect Protocol
Er 0Electronic Control Board (PCB) & Bus Communications
Incorrect module combination detected, no further operation possible.
Inspect Protocol
Er 1NTC Temperature Sensor & Thermistor
Temperature sensor interruption detected, oven does not heat, fans turn on.
Inspect Protocol
Er 11General System & Mechanical Integration
Bosch ER 11: Operational cycle fault detected during Oven / Microwave program execution.
Inspect Protocol
Er 15Heating Element, Thermostat & Safety Fuse
Oven is too hot, heating elements switched off, oven locked.
Inspect Protocol
Er 2General System & Mechanical Integration
Incorrect mains connection, continuous buzzer tone, mains connection incorrect
Inspect Protocol
Er 3Heating Element, Thermostat & Safety Fuse
Electronics overheated (> 100 °C), no heating, display darker, cooling fan on
Inspect Protocol
Er 4NTC Temperature Sensor & Thermistor
Temperature sensor short circuit detected, oven does not heat.
Inspect Protocol
Er 5Electronic Control Board (PCB) & Bus Communications
No clock function, no function in program position 'P'
Inspect Protocol
Er 6Door Lock Mechanism & Safety Interlock
Oven door does not lock, pyrolysis operation is no longer possible.
Inspect Protocol
Er 7Drive Motor, Inverter & Tachometer Sensor
The oven door fails to unlock and normal cooking operation is blocked.
Inspect Protocol
ER 9Heating Element, Thermostat & Safety Fuse
ROM check error after reset, all heating elements switched off.
Inspect Protocol
Er1NTC Temperature Sensor & Thermistor
Bosch Serie 6 / Serie 8 4D Hotair & EcoClean Direct Pyrolytic Oven: Cavity PT1000 thermocoup...
Inspect Protocol
CodesErreur.com

Premium appliance diagnostics & repair database.
Powered by AI to help certified technicians worldwide.

Trusted by professionals in CH & FR

Platform

Search DatabasePRO Diagnostic AIPRODiagnostic ToolsBrands

Workshop Tools

Brands (87)OEM ManualsFind Rating PlateParts Locator

For Technicians

SpecialistsTechnician ForumTech JobsPremium

Corporate

Terms of ServicePrivacy PolicyOfficial Swiss Repair Partner: Electroassistance
OPERATIONAL SAFETY SPECIFICATION

SAFETY DISCLAIMER

The technical information, diagnostic guides, error codes, and AI-generated suggestions provided on this website are intended exclusively for certified and qualified professionals. Appliance repair involves severe electrical hazards, high voltages, and mechanical risks that can result in fatal injury or severe property damage. If you are not a trained technician, do not attempt to repair any appliances. CodesErreur assumes no responsibility or liability for any damage, injury, or consequential losses resulting from the use of the information provided on this platform. You use all information entirely at your own risk.

© 2026 CodesErreur. All rights reserved.

Official Swiss Repair Partner: Electroassistance Terms of Service Privacy Policy