Field Actions
DISPATCHAlways disconnect appliance from 230V/400V mains before opening panels. Use CAT III multimeter for circuit testing.
Frequently Asked Questions: Bosch E845
FAQ TREEWhat does error code E845 mean on a Bosch appliance?
Bosch error code E845 indicates: Bosch Serie 6 / Serie 8 4D Hotair & EcoClean Direct Pyrolytic Oven: Combi-steam boiler water level optical sensor calibration failure E845; steam generator cannot verify boiler water level..
What is the root cause of Bosch error code E845?
The primary root cause for Bosch code E845 is: On Bosch ovens: Heavy lime scale coating optical refraction prism inside steam generator, defective optocoupler, or empty water reservoir tank..
How do I fix or resolve Bosch error code E845?
To resolve error code E845: Run automatic oven descaling program with recommended descaling liquid. Remove boiler unit and clean optical glass prism. Verify water pump flow. Turn function selector to 0, isolate power at circuit breaker for 60 seconds, restore power and set the digital clock.
Is it safe to clear Bosch error code E845 by resetting power?
Resetting power (unplugging for 5–10 minutes) clears temporary memory errors. However, if Bosch code E845 persists, the physical component causing On Bosch ovens: Heavy lime scale coating optical refraction prism inside steam generator, defective optocoupler, or empty water reservoir tank. must be inspected or replaced.
How do I test electrical resistance for Bosch code E845 using a multimeter?
Set a digital multimeter to ohms (Ω). Disconnect power and test Mechanical Pressure Switch Contacts / Inductive Frequency Sensor across Across switch spade contacts with harness unplugged; electronic output: 40Hz–50Hz frequency signal. Expected nominal reading is Mechanical: Continuity 0.0Ω–0.2Ω (Empty: 11-12, Full: 11-14). Electronic: 20Ω–45Ω coil resistance.. Tolerance: Mechanical switch contacts must transition cleanly on gentle breath pressure. Coil ~22Ω ±5%..
What safety protocol must be followed before servicing Bosch code E845?
Standard electrical safety protocol: 1. Disconnect 230V mains power before opening panels. 2. Verify zero voltage at test points. 3. Allow hot water or heating elements to cool below 30°C before handling.
Community Verification
COMMUNITYDid this solution resolve the issue?