Skip to content
CodesErreur.comSWISS PRO ENGINE
Core Diagnostics
DiagnosticsBrandsOEM ManualsSpecialistsAI EngineerPRO
Workshop Tools
Diagnostic ToolsNEW
Hardware interfaces & test probes
Find Rating Plate
Locate exact E-Nr, PNC & serial codes
Parts Locator
Global OEM spare parts suppliers
Community & Career
Academy & Courses
Masterclasses by senior technicians
Certification ExamsPRO
Verify your B2B technical credentials
Elite Forum
Peer-to-peer field troubleshooting
Tech Jobs
B2B recruitment & field opportunities
Leaderboard
Global ranking of verified specialists
Certified Appliance Engineering EcosystemApply for Certification →
Language Selector
Account & Access
Upgrade PRO
Back to Search
OEM VERIFIED BENCH
OFFICIAL FAULT CODEF11
Faber
Faber // OFFICIAL DIAGNOSTIC BENCH

Faber F11

DishwasherDrainage System & Drain Pump
Premium built-in dishwasher with open illuminated stainless steel interior and precision spray arms
Dishwasher
Select Appliance Type
0ms Instant Telemetry Switch
Other Brands Sharing Code F11:MieleF11WhirlpoolF11IndesitF11BauknechtF11AristonF11LiebherrF11SchulthessF11ScholtèsF11Schaub LorenzF11AskoF11

Symptom / Description

FAULT

Faber Silence Pro 42dB / Integrated Smart Touch Dishwasher: Diagnostic fault code F11 registered by the microcomputer controller. Detergent / rinse aid dispenser actuator coil open circuit.

TELEMETRY // LIVESIG: FAULT_DETECTED

Root Cause

ROOT CAUSE

On Faber appliances engineered with Inverter-driven high-pressure circulation pump, ActiveDry automatic door release, and optical turbidity wash sensor: dispenser solenoid or wax motor burnt out. Metrological tolerance verification: Dispenser coil 1.8 kOhms..

CIRCUIT // SUBSYSTEMLOGIC: ROOT_ISOLATED

Repair Instructions

UNLOCKED
1Disconnect mains power before servicing. Unplug the harness at the main PCB and use a calibrated digital multimeter: replace detergent dispenser actuator assembly. Inspect contacts for pin oxidation or loose terminals. Replace defective part if out of tolerance, re-energize and clear error: Open dishwasher door slightly, press and hold the Start/Reset button for 4 seconds until the active program LED turns off and the drain pump runs for 30 seconds. Power off, wait 10 seconds, then power on.
AI diagnostic workshop engine analyzing appliance circuit schematics and error telemetry in real time
AI WORKSHOP PROTOCOL ENGINE
Direct extraction from OEM factory manuals & wiring schematics

Field Actions

DISPATCH
Need Help? Call a Certified TechnicianWorldwide Faber Parts Finder
Electrical & Safety Protocol

Always disconnect appliance from 230V/400V mains before opening panels. Use CAT III multimeter for circuit testing.

CALIBRATED BENCH PROTOCOL // CAT III 600V

Workshop Verification & Safety Checklist

WORKSHOP VERIFICATION PROTOCOLDrainage System & Drain PumpDishwasher
2. Multimeter & Electrical Bench Tests (Ω)
MODE: OHMMETER (Ω)AUTO-RANGE
Precision digital multimeter probes measuring electrical resistance in Ohms on an appliance control board
CALIBRATED METROLOGY RESISTANCE BENCH (CAT III)
Nominal Resistance (Ω)
160Ω–220Ω (Sync 230V) / 20Ω–45Ω (3-Phase BLDC)NOMINAL
0 Ω (SHORT)CALIBRATED BAND∞ OL (OPEN)
▲ NOMINAL OPERATING WINDOW
Target Component:Drain Pump Motor Stator Coils
Test Pins & Connections
PROBE (+)
PROBE (-)
Across pump motor spade terminals (L-N unclipped)
Tolerance & Diagnostic Criteria±10% balance. Insulation resistance between coil and motor chassis must exceed 20MΩ.
1. Pre-Intervention Electrical Safety Protocols
  • !Electrical Safety Protocol: Isolate 230V mains power before accessing the lower pump housing.
  • !Prepare a shallow basin and absorption towels: expect 3 to 10 liters of stagnant trapped water upon filter opening.
  • !Beware of sharp foreign objects (broken glass, needles, screws) trapped inside the impeller cavity.
3. Preliminary Mechanical & Visual Checks
  • Unscrew coin trap filter and clear all foreign debris (coins, hairpins, bra underwires).
  • Rotate pump impeller manually: synchronous magnetic rotors should snap cleanly in 90° intervals without jamming.
  • Check drain hose for kinks, blockages, or unpunched sink spigots; verify drain height is between 65cm and 100cm.
Perform these diagnostic steps before triggering AI Deep Search or replacing boards.Certified Workshop Routine

Frequently Asked Questions: Faber F11

FAQ TREE
What does error code F11 mean on a Faber appliance?

Faber error code F11 indicates: Faber Silence Pro 42dB / Integrated Smart Touch Dishwasher: Diagnostic fault code F11 registered by the microcomputer controller. Detergent / rinse aid dispenser actuator coil open circuit..

What is the root cause of Faber error code F11?

The primary root cause for Faber code F11 is: On Faber appliances engineered with Inverter-driven high-pressure circulation pump, ActiveDry automatic door release, and optical turbidity wash sensor: dispenser solenoid or wax motor burnt out. Metrological tolerance verification: Dispenser coil 1.8 kOhms...

How do I fix or resolve Faber error code F11?

To resolve error code F11: Disconnect mains power before servicing. Unplug the harness at the main PCB and use a calibrated digital multimeter: replace detergent dispenser actuator assembly. Inspect contacts for pin oxidation or loose terminals. Replace defective part if out of tolerance, re-energize and clear error: Open dishwasher door slightly, press and hold the Start/Reset button for 4 seconds until the active program LED turns off and the drain pump runs for 30 seconds. Power off, wait 10 seconds, then power on.

Is it safe to clear Faber error code F11 by resetting power?

Resetting power (unplugging for 5–10 minutes) clears temporary memory errors. However, if Faber code F11 persists, the physical component causing On Faber appliances engineered with Inverter-driven high-pressure circulation pump, ActiveDry automatic door release, and optical turbidity wash sensor: dispenser solenoid or wax motor burnt out. Metrological tolerance verification: Dispenser coil 1.8 kOhms.. must be inspected or replaced.

How do I test electrical resistance for Faber code F11 using a multimeter?

Set a digital multimeter to ohms (Ω). Disconnect power and test Drain Pump Motor Stator Coils across Across pump motor spade terminals (L-N unclipped). Expected nominal reading is 160Ω–220Ω (Sync 230V) / 20Ω–45Ω (3-Phase BLDC). Tolerance: ±10% balance. Insulation resistance between coil and motor chassis must exceed 20MΩ..

What safety protocol must be followed before servicing Faber code F11?

Standard electrical safety protocol: 1. Disconnect 230V mains power before opening panels. 2. Verify zero voltage at test points. 3. Allow hot water or heating elements to cool below 30°C before handling.

Community Verification

COMMUNITY

Did this solution resolve the issue?

SEMANTIC KNOWLEDGE GRAPH // FABER

Related Faber Dishwasher Error Codes

Diagnostic Link Mesh14 OEM Cross-References

Cross-referenced diagnostic codes for technicians inspecting similar component subsystems.

F12Drainage System & Drain Pump
Faber Silence Pro 42dB / Integrated Smart Touch Dishwasher: Diagnostic fault code F12 regist...
Inspect Protocol
F13Drainage System & Drain Pump
Faber Silence Pro 42dB / Integrated Smart Touch Dishwasher: Diagnostic fault code F13 regist...
Inspect Protocol
F14Drainage System & Drain Pump
Faber Silence Pro 42dB / Integrated Smart Touch Dishwasher: Diagnostic fault code F14 regist...
Inspect Protocol
F15Drainage System & Drain Pump
Faber Silence Pro 42dB / Integrated Smart Touch Dishwasher: Diagnostic fault code F15 regist...
Inspect Protocol
F5Drainage System & Drain Pump
Faber Silence Pro 42dB / Integrated Smart Touch Dishwasher: Diagnostic fault code F5 registe...
Inspect Protocol
F6Drainage System & Drain Pump
Faber Silence Pro 42dB / Integrated Smart Touch Dishwasher: Diagnostic fault code F6 registe...
Inspect Protocol
F7Water Level Pressure Switch & Air Dome
Faber Silence Pro 42dB / Integrated Smart Touch Dishwasher: Diagnostic fault code F7 registe...
Inspect Protocol
F8NTC Temperature Sensor & Thermistor
Faber Silence Pro 42dB / Integrated Smart Touch Dishwasher: Diagnostic fault code F8 registe...
Inspect Protocol
F9Drainage System & Drain Pump
Faber Silence Pro 42dB / Integrated Smart Touch Dishwasher: Diagnostic fault code F9 registe...
Inspect Protocol
E1Drainage System & Drain Pump
Faber Silence Pro 42dB / Integrated Smart Touch Dishwasher: Diagnostic fault code E1 registe...
Inspect Protocol
E2Drainage System & Drain Pump
Faber Silence Pro 42dB / Integrated Smart Touch Dishwasher: Diagnostic fault code E2 registe...
Inspect Protocol
E3Drainage System & Drain Pump
Faber Silence Pro 42dB / Integrated Smart Touch Dishwasher: Diagnostic fault code E3 registe...
Inspect Protocol
E4Drainage System & Drain Pump
Faber Silence Pro 42dB / Integrated Smart Touch Dishwasher: Diagnostic fault code E4 registe...
Inspect Protocol
E5Drainage System & Drain Pump
Faber Silence Pro 42dB / Integrated Smart Touch Dishwasher: Diagnostic fault code E5 registe...
Inspect Protocol
CodesErreur.com

Premium appliance diagnostics & repair database.
Powered by AI to help certified technicians worldwide.

Trusted by professionals in CH & FR

Platform

Search DatabasePRO Diagnostic AIPRODiagnostic ToolsBrands

Workshop Tools

Brands (87)OEM ManualsFind Rating PlateParts Locator

For Technicians

SpecialistsTechnician ForumTech JobsPremium

Corporate

Terms of ServicePrivacy PolicyOfficial Swiss Repair Partner: Electroassistance
OPERATIONAL SAFETY SPECIFICATION

SAFETY DISCLAIMER

The technical information, diagnostic guides, error codes, and AI-generated suggestions provided on this website are intended exclusively for certified and qualified professionals. Appliance repair involves severe electrical hazards, high voltages, and mechanical risks that can result in fatal injury or severe property damage. If you are not a trained technician, do not attempt to repair any appliances. CodesErreur assumes no responsibility or liability for any damage, injury, or consequential losses resulting from the use of the information provided on this platform. You use all information entirely at your own risk.

© 2026 CodesErreur. All rights reserved.

Official Swiss Repair Partner: Electroassistance Terms of Service Privacy Policy