FAGOR F01 — Oven
[ACTIVE]Fagor Masterchef / Innova / 6H Pyrolytic Multi-Function Oven: Temperature sensor probe open circuit F01; controller senses completely broken cavity temperature sensor loop.
On FAGOR ovens featuring Masterchef 6H pyrolytic thermal management, high-flow tangential cooling turbine, and digital programmer interface: Broken internal PT500 RTD platinum filament, disconnected connector behind rear insulation, or fractured probe wires.
Unplug oven from power. Measure probe resistance (~540 Ω at 20°C). Inspect sensor wiring behind rear fiberglass blanket. Replace probe if open. Return function selector to 0, isolate the power distribution breaker for 60 seconds, restore power and configure the clock.