Field Actions
DISPATCHAlways disconnect appliance from 230V/400V mains before opening panels. Use CAT III multimeter for circuit testing.
Frequently Asked Questions: FAGOR F2
FAQ TREEWhat does error code F2 mean on a FAGOR appliance?
FAGOR error code F2 indicates: Fagor Eco Sensor / Innova / 1LV / 2LV Dishwasher: Sump water evacuation timeout F2; water remains detected in the bottom sump basin after drain phase timing expires..
What is the root cause of FAGOR error code F2?
The primary root cause for FAGOR code F2 is: On FAGOR dishwashers featuring Eco Sensor turbidity optoelectronics, Innova hydraulic distribution, and AquaStop active leak containment: Blocked sink spigot connection, debris in drain pump volute, or open drain pump winding (~180–220 Ω)..
How do I fix or resolve FAGOR error code F2?
To resolve error code F2: Check sink drain connector and punch out membrane if newly installed. Measure drain pump motor resistance (~180–220 Ω). Press and hold the Start/Stop key for 5 seconds until the program indicator light clears and drain pump runs, then switch off.
Is it safe to clear FAGOR error code F2 by resetting power?
Resetting power (unplugging for 5–10 minutes) clears temporary memory errors. However, if FAGOR code F2 persists, the physical component causing On FAGOR dishwashers featuring Eco Sensor turbidity optoelectronics, Innova hydraulic distribution, and AquaStop active leak containment: Blocked sink spigot connection, debris in drain pump volute, or open drain pump winding (~180–220 Ω). must be inspected or replaced.
How do I test electrical resistance for FAGOR code F2 using a multimeter?
Set a digital multimeter to ohms (Ω). Disconnect power and test Mechanical Pressure Switch Contacts / Inductive Frequency Sensor across Across switch spade contacts with harness unplugged; electronic output: 40Hz–50Hz frequency signal. Expected nominal reading is Mechanical: Continuity 0.0Ω–0.2Ω (Empty: 11-12, Full: 11-14). Electronic: 20Ω–45Ω coil resistance.. Tolerance: Mechanical switch contacts must transition cleanly on gentle breath pressure. Coil ~22Ω ±5%..
What safety protocol must be followed before servicing FAGOR code F2?
Standard electrical safety protocol: 1. Disconnect 230V mains power before opening panels. 2. Verify zero voltage at test points. 3. Allow hot water or heating elements to cool below 30°C before handling.
Community Verification
COMMUNITYDid this solution resolve the issue?