FAGOR F2 — Dishwasher
[ACTIVE]Fagor Eco Sensor / Innova / 1LV / 2LV Dishwasher: Sump water evacuation timeout F2; water remains detected in the bottom sump basin after drain phase timing expires.
On FAGOR dishwashers featuring Eco Sensor turbidity optoelectronics, Innova hydraulic distribution, and AquaStop active leak containment: Blocked sink spigot connection, debris in drain pump volute, or open drain pump winding (~180–220 Ω).
Check sink drain connector and punch out membrane if newly installed. Measure drain pump motor resistance (~180–220 Ω). Press and hold the Start/Stop key for 5 seconds until the program indicator light clears and drain pump runs, then switch off.