FAGOR F5 — Dishwasher
[ACTIVE]Fagor Eco Sensor / Innova / 1LV / 2LV Dishwasher: Circulation wash motor electrical fault F5; wash pump fails to run and cycle stalls during wash stages.
On FAGOR dishwashers featuring Eco Sensor turbidity optoelectronics, Innova hydraulic distribution, and AquaStop active leak containment: Open motor windings (~70–110 Ω), defective starting capacitor (~4 µF), or tripped motor thermal protector.
Measure wash motor winding resistance (~70–110 Ω). Check run capacitor rating with a capacitance meter (~4 µF). Verify 230V AC arrival on call. Press and hold the Start/Stop key for 5 seconds until the program indicator light clears and drain pump runs, then switch off.