Field Actions
DISPATCHAlways disconnect appliance from 230V/400V mains before opening panels. Use CAT III multimeter for circuit testing.
Frequently Asked Questions: Faure E98
FAQ TREEWhat does error code E98 mean on a Faure appliance?
Faure error code E98 indicates: Faure FWG / FWF Series / Magic'45 Compact Washer: Incongruence between inverter software version and main motherboard firmware E98..
What is the root cause of Faure error code E98?
The primary root cause for Faure code E98 is: On Faure (Faure FWG / FWF Series / Magic'45 Compact Washer) models: Inverter board (FCV) replaced with incompatible revision or firmware build not supported by the existing main motherboard EWM software..
How do I fix or resolve Faure error code E98?
To resolve error code E98: Verify matching hardware and software version index on inverter and main motherboard barcode labels. Install matching FCV module. Press and hold Départ/Pause and Annulation buttons for 6 seconds until all status indicators flash synchronously and clear fault memory.
Is it safe to clear Faure error code E98 by resetting power?
Resetting power (unplugging for 5–10 minutes) clears temporary memory errors. However, if Faure code E98 persists, the physical component causing On Faure (Faure FWG / FWF Series / Magic'45 Compact Washer) models: Inverter board (FCV) replaced with incompatible revision or firmware build not supported by the existing main motherboard EWM software. must be inspected or replaced.
How do I test electrical resistance for Faure code E98 using a multimeter?
Set a digital multimeter to ohms (Ω). Disconnect power and test 3-Phase Motor Windings / Tacho Generator / Carbon Brushes across Across phase pins U-V, V-W, U-W on motor harness; across tacho pins. Expected nominal reading is 3Ω–6Ω (BLDC phase U-V-W) / 60Ω–180Ω (Tacho coil) / 1.5Ω–3.5Ω (Universal stator). Tolerance: BLDC phase winding values must be strictly balanced within ±0.3Ω. Hand rotation generates 1V–4V AC on tacho..
What safety protocol must be followed before servicing Faure code E98?
Standard electrical safety protocol: 1. Disconnect 230V mains power before opening panels. 2. Verify zero voltage at test points. 3. Allow hot water or heating elements to cool below 30°C before handling.
Community Verification
COMMUNITYDid this solution resolve the issue?



