Field Actions
DISPATCHAlways disconnect appliance from 230V/400V mains before opening panels. Use CAT III multimeter for circuit testing.
Frequently Asked Questions: Favorit E42
FAQ TREEWhat does error code E42 mean on a Favorit appliance?
Favorit error code E42 indicates: Favorit ProCare / SwissWash High-Efficiency Electronic Washing Machine: Diagnostic fault code E42 registered by the microcomputer controller. Washing machine door safety interlock solenoid/PTC driver triac short circuit on main board (code E42).
What is the root cause of Favorit error code E42?
The primary root cause for Favorit code E42 is: On Favorit SwissLine and European precision appliances built for high durability engineered with Eco-Inverter BLDC direct drive motor (5.5-8.0 Ω per phase), 2100W heating element (24-27 Ω), 10 kΩ NTC thermistor at 25°C, pneumatic pressure switch with sealed air trap, and instant bi-metal door lock: internal short in door lock PTC pill or solenoid winding caused overcurrent that punctured the semiconductor. Metrological tolerance verification: door lock triac terminal T1-T2 cold resistance >1.0 MΩ; door latch PTC pill resistance nominal 800-1400 Ω..
How do I fix or resolve Favorit error code E42?
To resolve error code E42: Disconnect mains power before servicing. Unplug the harness at the main PCB and use a calibrated digital multimeter: measure resistance across door lock PTC terminals (expect ~1100 Ω); replace both lock assembly and damaged PCB. Inspect contacts for pin oxidation or loose terminals. Replace defective part if out of tolerance, re-energize and clear error: Turn cycle selector to Stop. Hold Start/Pause and Eco buttons together for 5 seconds until display chimes and shows 'CLr', wiping diagnostic fault memory.
Is it safe to clear Favorit error code E42 by resetting power?
Resetting power (unplugging for 5–10 minutes) clears temporary memory errors. However, if Favorit code E42 persists, the physical component causing On Favorit SwissLine and European precision appliances built for high durability engineered with Eco-Inverter BLDC direct drive motor (5.5-8.0 Ω per phase), 2100W heating element (24-27 Ω), 10 kΩ NTC thermistor at 25°C, pneumatic pressure switch with sealed air trap, and instant bi-metal door lock: internal short in door lock PTC pill or solenoid winding caused overcurrent that punctured the semiconductor. Metrological tolerance verification: door lock triac terminal T1-T2 cold resistance >1.0 MΩ; door latch PTC pill resistance nominal 800-1400 Ω. must be inspected or replaced.
How do I test electrical resistance for Favorit code E42 using a multimeter?
Set a digital multimeter to ohms (Ω). Disconnect power and test NTC Temperature Sensor Probe (Thermistor) across Across sensor pins 1-2 (unplugged harness). Expected nominal reading is 4.8kΩ–12kΩ (at 20°C–25°C). Tolerance: Negative temperature coefficient: resistance drops smoothly when warmed with fingers. OL = open circuit..
What safety protocol must be followed before servicing Favorit code E42?
Standard electrical safety protocol: 1. Disconnect 230V mains power before opening panels. 2. Verify zero voltage at test points. 3. Allow hot water or heating elements to cool below 30°C before handling.
Community Verification
COMMUNITYDid this solution resolve the issue?