Skip to content
CodesErreur.comSWISS PRO ENGINE
Core Diagnostics
DiagnosticsBrandsOEM ManualsSpecialistsAI EngineerPRO
Workshop Tools
Diagnostic ToolsNEW
Hardware interfaces & test probes
Find Rating Plate
Locate exact E-Nr, PNC & serial codes
Parts Locator
Global OEM spare parts suppliers
Community & Career
Academy & Courses
Masterclasses by senior technicians
Certification ExamsPRO
Verify your B2B technical credentials
Elite Forum
Peer-to-peer field troubleshooting
Tech Jobs
B2B recruitment & field opportunities
Leaderboard
Global ranking of verified specialists
Certified Appliance Engineering EcosystemApply for Certification →
Language Selector
ENFRDEITESPT
ENEnglishFRFrançaisDEDeutschITItalianoESEspañolPTPortuguês
Account & Access
Upgrade PRO
Back to Search
OEM VERIFIED BENCH
OFFICIAL FAULT CODEE42
Favorit
Favorit // OFFICIAL DIAGNOSTIC BENCH

Favorit Washing Machine E42

Washing MachineNTC Temperature Sensor & Thermistor
Luxury front-loading washing machine in brushed titanium with illuminated dark glass drum
Washing Machine
Other Brands Sharing Code E42:BoschE42SiemensE42ElectroluxE42AEGE42NeffE42ZanussiE42Arthur MartinE42GaggenauE42CastorE42FaureE42

Symptom / Description

FAULT

Favorit ProCare / SwissWash High-Efficiency Electronic Washing Machine: Diagnostic fault code E42 registered by the microcomputer controller. Washing machine door safety interlock solenoid/PTC driver triac short circuit on main board (code E42)

TELEMETRY // LIVESIG: FAULT_DETECTED

Root Cause

ROOT CAUSE

On Favorit SwissLine and European precision appliances built for high durability engineered with Eco-Inverter BLDC direct drive motor (5.5-8.0 Ω per phase), 2100W heating element (24-27 Ω), 10 kΩ NTC thermistor at 25°C, pneumatic pressure switch with sealed air trap, and instant bi-metal door lock: internal short in door lock PTC pill or solenoid winding caused overcurrent that punctured the semiconductor. Metrological tolerance verification: door lock triac terminal T1-T2 cold resistance >1.0 MΩ; door latch PTC pill resistance nominal 800-1400 Ω.

CIRCUIT // SUBSYSTEMLOGIC: ROOT_ISOLATED

Repair Instructions

UNLOCKED
1Disconnect mains power before servicing. Unplug the harness at the main PCB and use a calibrated digital multimeter: measure resistance across door lock PTC terminals (expect ~1100 Ω); replace both lock assembly and damaged PCB. Inspect contacts for pin oxidation or loose terminals. Replace defective part if out of tolerance, re-energize and clear error: Turn cycle selector to Stop. Hold Start/Pause and Eco buttons together for 5 seconds until display chimes and shows 'CLr', wiping diagnostic fault memory.
AI diagnostic workshop engine analyzing appliance circuit schematics and error telemetry in real time
AI WORKSHOP PROTOCOL ENGINE
Direct extraction from OEM factory manuals & wiring schematics

Field Actions

DISPATCH
Need Help? Call a Certified TechnicianWorldwide Favorit Parts Finder
Electrical & Safety Protocol

Always disconnect appliance from 230V/400V mains before opening panels. Use CAT III multimeter for circuit testing.

SWISS ATELIER TECHNICAL BLUEPRINT // 2026 SCHEMATIC STANDARD

Thermal & Heating Loop

Calrod Heating Element R1, Safety Klixon & NTC Thermistor Probe

CALIBRATED TEST POINTS (TP1 / TP2)
ACTIVE MULTIMETER BENCH
MAIN PCB CONTROLLER32-BIT MCUFIRMWARE v26.4SOLID-STATE RELAYTRIAC TY1 // 16A 600V230V AC MAINSLINE FILTER L-NJ1J2TP1TP2PRECISION BENCH METERAUTO-RANGE ΩCAT III24.6 ΩVΩCOMHEATING ELEMENT R1HEATER R1: 20-28 ΩSAFETY THERMOSTAT (KLIXON)NTC SENSOR (4.8-12kΩ)
Target Component
NTC Temperature Sensor Probe (Thermistor)
Nominal Resistance / Test Range
4.8kΩ–12kΩ (at 20°C–25°C)
Test Harness Pins
Across sensor pins 1-2 (unplugged harness)
Diagnostic Verification Rule
Zero or OL indicates open heating element or tripped safety thermostat. Check insulation to earth.
CALIBRATED BENCH PROTOCOL // CAT III 600V

Workshop Verification & Safety Checklist

WORKSHOP VERIFICATION PROTOCOLNTC Temperature Sensor & ThermistorWashing Machine
2. Multimeter & Electrical Bench Tests (Ω)
MODE: OHMMETER (Ω)AUTO-RANGE
Precision digital multimeter probes measuring electrical resistance in Ohms on an appliance control board
CALIBRATED METROLOGY RESISTANCE BENCH (CAT III)
Nominal Resistance (Ω)
4.8kΩ–12kΩ (at 20°C–25°C)NOMINAL
0 Ω (SHORT)CALIBRATED BAND∞ OL (OPEN)
▲ NOMINAL OPERATING WINDOW
Target Component:NTC Temperature Sensor Probe (Thermistor)
Test Pins & Connections
PROBE (+)
PROBE (-)
Across sensor pins 1-2 (unplugged harness)
Tolerance & Diagnostic CriteriaNegative temperature coefficient: resistance drops smoothly when warmed with fingers. OL = open circuit.
1. Pre-Intervention Electrical Safety Protocols
  • !Electrical Safety Protocol: Disconnect 230V electrical mains power before removing appliance side or rear panels.
  • !Ensure tub water or heating chamber has cooled below 30°C before unclipping thermistor probe.
  • !Use CAT III 600V/1000V insulated test probes when tng at PCB edge connectors.
3. Preliminary Mechanical & Visual Checks
  • Inspect sensor immersion sleeve for calcification, limescale scale, or thermal paste degradation.
  • Check wiring harness for pinch points, chafing against chassis metal, and terminal pin oxidation.
  • Verify probe is firmly seated in its rubber grommet or bracket inside the water/air circuit.
Perform these diagnostic steps before triggering AI Deep Search or replacing boards.Certified Workshop Routine

Frequently Asked Questions: Favorit E42

FAQ TREE
What does error code E42 mean on a Favorit appliance?

Favorit error code E42 indicates: Favorit ProCare / SwissWash High-Efficiency Electronic Washing Machine: Diagnostic fault code E42 registered by the microcomputer controller. Washing machine door safety interlock solenoid/PTC driver triac short circuit on main board (code E42).

What is the root cause of Favorit error code E42?

The primary root cause for Favorit code E42 is: On Favorit SwissLine and European precision appliances built for high durability engineered with Eco-Inverter BLDC direct drive motor (5.5-8.0 Ω per phase), 2100W heating element (24-27 Ω), 10 kΩ NTC thermistor at 25°C, pneumatic pressure switch with sealed air trap, and instant bi-metal door lock: internal short in door lock PTC pill or solenoid winding caused overcurrent that punctured the semiconductor. Metrological tolerance verification: door lock triac terminal T1-T2 cold resistance >1.0 MΩ; door latch PTC pill resistance nominal 800-1400 Ω..

How do I fix or resolve Favorit error code E42?

To resolve error code E42: Disconnect mains power before servicing. Unplug the harness at the main PCB and use a calibrated digital multimeter: measure resistance across door lock PTC terminals (expect ~1100 Ω); replace both lock assembly and damaged PCB. Inspect contacts for pin oxidation or loose terminals. Replace defective part if out of tolerance, re-energize and clear error: Turn cycle selector to Stop. Hold Start/Pause and Eco buttons together for 5 seconds until display chimes and shows 'CLr', wiping diagnostic fault memory.

Is it safe to clear Favorit error code E42 by resetting power?

Resetting power (unplugging for 5–10 minutes) clears temporary memory errors. However, if Favorit code E42 persists, the physical component causing On Favorit SwissLine and European precision appliances built for high durability engineered with Eco-Inverter BLDC direct drive motor (5.5-8.0 Ω per phase), 2100W heating element (24-27 Ω), 10 kΩ NTC thermistor at 25°C, pneumatic pressure switch with sealed air trap, and instant bi-metal door lock: internal short in door lock PTC pill or solenoid winding caused overcurrent that punctured the semiconductor. Metrological tolerance verification: door lock triac terminal T1-T2 cold resistance >1.0 MΩ; door latch PTC pill resistance nominal 800-1400 Ω. must be inspected or replaced.

How do I test electrical resistance for Favorit code E42 using a multimeter?

Set a digital multimeter to ohms (Ω). Disconnect power and test NTC Temperature Sensor Probe (Thermistor) across Across sensor pins 1-2 (unplugged harness). Expected nominal reading is 4.8kΩ–12kΩ (at 20°C–25°C). Tolerance: Negative temperature coefficient: resistance drops smoothly when warmed with fingers. OL = open circuit..

What safety protocol must be followed before servicing Favorit code E42?

Standard electrical safety protocol: 1. Disconnect 230V mains power before opening panels. 2. Verify zero voltage at test points. 3. Allow hot water or heating elements to cool below 30°C before handling.

Community Verification

COMMUNITY

Did this solution resolve the issue?

SEMANTIC KNOWLEDGE GRAPH // FAVORIT

Related Favorit Washing Machine Error Codes

Diagnostic Link Mesh14 OEM Cross-References

Cross-referenced diagnostic codes for technicians inspecting similar component subsystems.

E11Washing Machine
NTC Temperature Sensor & Thermistor
Favorit ProCare / SwissWash High-Efficiency Electronic Washing Machine: Diagnostic fault cod...
Inspect Protocol
E12Washing Machine
NTC Temperature Sensor & Thermistor
Favorit ProCare / SwissWash High-Efficiency Electronic Washing Machine: Diagnostic fault cod...
Inspect Protocol
E13Washing Machine
NTC Temperature Sensor & Thermistor
Favorit ProCare / SwissWash High-Efficiency Electronic Washing Machine: Diagnostic fault cod...
Inspect Protocol
E21Washing Machine
NTC Temperature Sensor & Thermistor
Favorit ProCare / SwissWash High-Efficiency Electronic Washing Machine: Diagnostic fault cod...
Inspect Protocol
E22Washing Machine
NTC Temperature Sensor & Thermistor
Favorit ProCare / SwissWash High-Efficiency Electronic Washing Machine: Diagnostic fault cod...
Inspect Protocol
E23Washing Machine
NTC Temperature Sensor & Thermistor
Favorit ProCare / SwissWash High-Efficiency Electronic Washing Machine: Diagnostic fault cod...
Inspect Protocol
E31Washing Machine
NTC Temperature Sensor & Thermistor
Favorit ProCare / SwissWash High-Efficiency Electronic Washing Machine: Diagnostic fault cod...
Inspect Protocol
E32Washing Machine
NTC Temperature Sensor & Thermistor
Favorit ProCare / SwissWash High-Efficiency Electronic Washing Machine: Diagnostic fault cod...
Inspect Protocol
E33Washing Machine
NTC Temperature Sensor & Thermistor
Favorit ProCare / SwissWash High-Efficiency Electronic Washing Machine: Diagnostic fault cod...
Inspect Protocol
E34Washing Machine
NTC Temperature Sensor & Thermistor
Favorit ProCare / SwissWash High-Efficiency Electronic Washing Machine: Diagnostic fault cod...
Inspect Protocol
E41Washing Machine
NTC Temperature Sensor & Thermistor
Favorit ProCare / SwissWash High-Efficiency Electronic Washing Machine: Diagnostic fault cod...
Inspect Protocol
E42Washing Machine
NTC Temperature Sensor & Thermistor
Favorit ProCare / SwissWash High-Efficiency Electronic Washing Machine: Diagnostic fault cod...
Inspect Protocol
E43Washing Machine
NTC Temperature Sensor & Thermistor
Favorit ProCare / SwissWash High-Efficiency Electronic Washing Machine: Diagnostic fault cod...
Inspect Protocol
E44Washing Machine
NTC Temperature Sensor & Thermistor
Favorit ProCare / SwissWash High-Efficiency Electronic Washing Machine: Diagnostic fault cod...
Inspect Protocol
CodesErreur.com

Premium appliance diagnostics & repair database.
Powered by AI to help certified technicians worldwide.

Trusted by professionals in CH & FR

Platform

Search DatabasePRO Diagnostic AIPRODiagnostic ToolsBrands

Workshop Tools

Brands (87)OEM ManualsFind Rating PlateParts Locator

For Technicians

SpecialistsTechnician ForumTech JobsPremium

Corporate

Terms of ServicePrivacy PolicyOfficial Swiss Repair Partner: Electroassistance
OPERATIONAL SAFETY SPECIFICATION

SAFETY DISCLAIMER

The technical information, diagnostic guides, error codes, and AI-generated suggestions provided on this website are intended exclusively for certified and qualified professionals. Appliance repair involves severe electrical hazards, high voltages, and mechanical risks that can result in fatal injury or severe property damage. If you are not a trained technician, do not attempt to repair any appliances. CodesErreur assumes no responsibility or liability for any damage, injury, or consequential losses resulting from the use of the information provided on this platform. You use all information entirely at your own risk.

© 2026 CodesErreur. All rights reserved.

Terms of Service Privacy Policy