Field Actions
DISPATCHAlways disconnect appliance from 230V/400V mains before opening panels. Use CAT III multimeter for circuit testing.
Frequently Asked Questions: Franke ER31
FAQ TREEWhat does error code ER31 mean on a Franke appliance?
Franke error code ER31 indicates: Franke Mythos / Maris FlexPro Induction & Flush Glass Gas Cooktop: Diagnostic fault code ER31 registered by the microcomputer controller. Configuration data mismatch between master and slave induction inverters.
What is the root cause of Franke error code ER31?
The primary root cause for Franke code ER31 is: On Franke appliances engineered with FlexPro multi-coil induction generator with E.G.O. power electronics, continuous pan-tracking sensors, and optical thermal cutoff circuitry: inverter boards have mismatched firmware versions Metrological tolerance verification: nominal NTC thermistor 10.0 kΩ at 25°C, 32.0 kΩ at 0°C..
How do I fix or resolve Franke error code ER31?
To resolve error code ER31: Disconnect mains power before servicing. Unplug the harness at the main PCB and use a calibrated digital multimeter: measure sensor resistance across probe pins (expected ~10 kΩ at 25°C). Inspect contacts for pin oxidation or loose terminals. Replace defective part if out of tolerance, re-energize and clear error: Clean and thoroughly dry the glass surface. Disconnect main breaker for 2 minutes. Restore power and immediately press and hold the Key Lock sensor for 5 seconds until double acoustic confirmation sounds.
Is it safe to clear Franke error code ER31 by resetting power?
Resetting power (unplugging for 5–10 minutes) clears temporary memory errors. However, if Franke code ER31 persists, the physical component causing On Franke appliances engineered with FlexPro multi-coil induction generator with E.G.O. power electronics, continuous pan-tracking sensors, and optical thermal cutoff circuitry: inverter boards have mismatched firmware versions Metrological tolerance verification: nominal NTC thermistor 10.0 kΩ at 25°C, 32.0 kΩ at 0°C. must be inspected or replaced.
How do I test electrical resistance for Franke code ER31 using a multimeter?
Set a digital multimeter to ohms (Ω). Disconnect power and test NTC Temperature Sensor Probe (Thermistor) across Across sensor pins 1-2 (unplugged harness). Expected nominal reading is 4.8kΩ–12kΩ (at 20°C–25°C). Tolerance: Negative temperature coefficient: resistance drops smoothly when warmed with fingers. OL = open circuit..
What safety protocol must be followed before servicing Franke code ER31?
Standard electrical safety protocol: 1. Disconnect 230V mains power before opening panels. 2. Verify zero voltage at test points. 3. Allow hot water or heating elements to cool below 30°C before handling.
Community Verification
COMMUNITYDid this solution resolve the issue?



