Gaggenau E20 — Dishwasher
[ACTIVE]Gaggenau 200 Series / 400 Series Zeolith & push-to-open dishwasher: Circulation pump BLDC winding resistance fault E20; phase impedance imbalance or open coil detected by inverter.
On Gaggenau dishwashers: Open or shorted winding in 3-phase BLDC heat pump motor, moisture ingress in motor plug, or inverter driver failure.
Disconnect power. Measure 3-phase motor winding resistances between pins 1-2, 2-3, 1-3 on heat pump motor (nominal ~88 Ω ± 5% across all 3 phases). Press and hold illuminated Start key for 4 seconds until '0:01' abort confirms, close door for final drainage, power off.