Gaggenau E23 — Dishwasher
[ACTIVE]Gaggenau 200 Series / 400 Series Zeolith & push-to-open dishwasher: Drain pump winding resistance error E23; inverter reports open circuit, phase short, or coil defect in drain motor.
On Gaggenau dishwashers: Open or burnt winding in BLDC drain pump (nominal ~88 Ω across all 3 phases), or corroded 3-pin wiring harness connector.
Disconnect mains. Measure BLDC drain pump winding resistance (pins 1-2, 2-3, 1-3 should all read ~88 Ω ± 5%). Replace drain pump if values diverge. Press and hold illuminated Start key for 4 seconds until '0:01' abort confirms, close door for final drainage, power off.