Haier E03 — Dishwasher
[ACTIVE]Haier I-Pro Shine / Washlogix Ultra Silence Dishwasher: Drain pump evacuation timeout E03; water remains detected in sump chamber after drain cycle timer elapses.
On Haier dishwashers powered by I-Pro Shine Ultra Silence brushless wash circulation pump, dual-zone inverter spray system, and micro-filtration: Toothpick or small bone jammed in pump impeller chamber, clogged corrugated drain hose, or worn pump motor (~160–220 Ω).
Remove sump filter cover and clear debris around drain impeller. Ensure hose is unobstructed to drain standpipe. Measure pump coil resistance (~160–220 Ω). Press Power button off, hold Half Load and Start buttons together while powering on until diagnostic test mode 01 displays, then power off.