Haier E05 — Dishwasher
[ACTIVE]Haier I-Pro Shine / Washlogix Ultra Silence Dishwasher: Water temperature sensor measurement anomaly E05; NTC probe signal resistance indicates temperature below -5°C or above 90°C.
On Haier dishwashers powered by I-Pro Shine Ultra Silence brushless wash circulation pump, dual-zone inverter spray system, and micro-filtration: Detergent residue film insulating thermistor head in sump, cracked thermistor bead, or moisture in wiring connector.
Unplug NTC sensor from sump housing. Clean stainless sensing face with vinegar/descaler. Measure resistance at room temperature (~47 kΩ at 25°C). Press Power button off, hold Half Load and Start buttons together while powering on until diagnostic test mode 01 displays, then power off.