Haier E4 — Dishwasher
[ACTIVE]Haier I-Pro Shine / Washlogix Ultra Silence Dishwasher: Anti-flood leak protection triggered E4; float switch in the bottom chassis pan rises and engages emergency drain.
On Haier dishwashers featuring I-Pro Shine Ultra Silence brushless wash circulation pump, dual-zone inverter spray system, and micro-filtration: Leaking sump seal, split recirculation pump casing, door perimeter gasket wear, or cracked fill hose connection.
Disconnect mains power. Sponge out water from bottom collection tray. Inspect sump gasket, pump hose clamps, and tub seams with dry paper. Test anti-flood microswitch continuity with a multimeter. Press Power button off, hold Half Load and Start buttons together while powering on until diagnostic test mode 01 displays, then power off.